{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/7581"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/7581","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"A General Approach to Common-Mode Signal Rejection with Application to Myo-electric Signal Measurements","abstract":"<p>A typical instrumentation problem is the detection of a differential signal in the presence of a common-mode signal. In the case of measuring myo-electric signals, the common-mode signals present can be 10²-10⁴ larger than the differential signal. In such instances, the attenuation of these unwanted common-mode signals require complex circuit designs.</p> <p>In this work an investigation of the common-mode signal path led to the development of a general approach to the problem of unwanted signals arising from common-mode signal sources. It was found possible to write the overall common-mode gain as a product of the differential amplifier common-mode response and the isolation gain. The isolation gain depends on the ratio of the impedance of the common-mode signal path to the differential amplifier input impedance. The impedance of the common-mode signal path may be increased by employing in the amplifier system a self-contained power supply and an output coupler device such as a transformer.</p> <p>The general approach was used to design an amplifier system to measure myo-electric signals. This amplifier system gave a much improved common-mode signal rejection over currently used systems which typically have 40 db of differential gain but only -30 db of common-mode gain at 60 Hz. The improvement in common-mode signal rejection was 25 db.</p>","abstract_html":"&lt;p&gt;A typical instrumentation problem is the detection of a differential signal in the presence of a common-mode signal. In the case of measuring myo-electric signals, the common-mode signals present can be 10²-10⁴ larger than the differential signal. In such instances, the attenuation of these unwanted common-mode signals require complex circuit designs.&lt;/p&gt; &lt;p&gt;In this work an investigation of the common-mode signal path led to the development of a general approach to the problem of unwanted signals arising from common-mode signal sources. It was found possible to write the overall common-mode gain as a product of the differential amplifier common-mode response and the isolation gain. The isolation gain depends on the ratio of the impedance of the common-mode signal path to the differential amplifier input impedance. The impedance of the common-mode signal path may be increased by employing in the amplifier system a self-contained power supply and an output coupler device such as a transformer.&lt;/p&gt; &lt;p&gt;The general approach was used to design an amplifier system to measure myo-electric signals. This amplifier system gave a much improved common-mode signal rejection over currently used systems which typically have 40 db of differential gain but only -30 db of common-mode gain at 60 Hz. The improvement in common-mode signal rejection was 25 db.&lt;/p&gt;","abstract_has_math":false,"creators":["Hayes, Rudy Hasler"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":["Barber, H.D.","Chisholm, S.H."],"committee_chairs":[],"committee_members":[],"year":1979,"date_issued":"1979-04","date_published":"1979-04","updated_at":"2026-11-18T19:32:04Z","subjects":["Electrical and Electronics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/11065"],"render_values":[{"text":"https://doi.org/10.71548/11065","href":"https://doi.org/10.71548/11065","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/285","1329","895429"],"render_values":[{"text":"opendissertations/285","href":null,"code":true},{"text":"1329","href":null,"code":true},{"text":"895429","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/7581","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/7581","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F7581","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Barber, H.D.","Chisholm, S.H."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Hayes, Rudy Hasler"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T16:39:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-18T16:39:47Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-07-13"]},{"key":"dc:date.issued","label":"Date","values":["1979-04"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical and Electronics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/285","1329","895429"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/7581","https://doi.org/10.71548/11065"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A typical instrumentation problem is the detection of a differential signal in the presence of a common-mode signal. In the case of measuring myo-electric signals, the common-mode signals present can be 10²-10⁴ larger than the differential signal. In such instances, the attenuation of these unwanted common-mode signals require complex circuit designs.</p> <p>In this work an investigation of the common-mode signal path led to the development of a general approach to the problem of unwanted signals arising from common-mode signal sources. It was found possible to write the overall common-mode gain as a product of the differential amplifier common-mode response and the isolation gain. The isolation gain depends on the ratio of the impedance of the common-mode signal path to the differential amplifier input impedance. The impedance of the common-mode signal path may be increased by employing in the amplifier system a self-contained power supply and an output coupler device such as a transformer.</p> <p>The general approach was used to design an amplifier system to measure myo-electric signals. This amplifier system gave a much improved common-mode signal rejection over currently used systems which typically have 40 db of differential gain but only -30 db of common-mode gain at 60 Hz. The improvement in common-mode signal rejection was 25 db.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Engineering (ME)"]},{"key":"dc:title","label":"Title","values":["A General Approach to Common-Mode Signal Rejection with Application to Myo-electric Signal Measurements"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Barber, H.D.","Chisholm, S.H."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Hayes, Rudy Hasler"],"dc:date.accessioned":["2014-06-18T16:39:47Z"],"dc:date.available":["2014-06-18T16:39:47Z"],"dc:date.created":["2009-07-13"],"dc:date.issued":["1979-04"],"dc:description.abstract":["<p>A typical instrumentation problem is the detection of a differential signal in the presence of a common-mode signal. In the case of measuring myo-electric signals, the common-mode signals present can be 10²-10⁴ larger than the differential signal. In such instances, the attenuation of these unwanted common-mode signals require complex circuit designs.</p> <p>In this work an investigation of the common-mode signal path led to the development of a general approach to the problem of unwanted signals arising from common-mode signal sources. It was found possible to write the overall common-mode gain as a product of the differential amplifier common-mode response and the isolation gain. The isolation gain depends on the ratio of the impedance of the common-mode signal path to the differential amplifier input impedance. The impedance of the common-mode signal path may be increased by employing in the amplifier system a self-contained power supply and an output coupler device such as a transformer.</p> <p>The general approach was used to design an amplifier system to measure myo-electric signals. This amplifier system gave a much improved common-mode signal rejection over currently used systems which typically have 40 db of differential gain but only -30 db of common-mode gain at 60 Hz. The improvement in common-mode signal rejection was 25 db.</p>"],"dc:description.degree":["Master of Engineering (ME)"],"dc:identifier.other":["opendissertations/285","1329","895429"],"dc:identifier.uri":["http://hdl.handle.net/11375/7581","https://doi.org/10.71548/11065"],"dc:subject":["Electrical and Electronics"],"dc:title":["A General Approach to Common-Mode Signal Rejection with Application to Myo-electric Signal Measurements"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:32:04Z"}