{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/8327"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/8327","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Dynamics of the ammonia laser","abstract":"<p>An experimental and theoretical study of the dynamics of NH₃ lasers is presented. The significant achievements of this work are summarized below. In initial experiments, a pulsed transversely-excited CO₂ laser operating on the 9R(30) transition is used to optically pump mixtures of NH₃ in buffer gas. A simple oscillator/amplifier system allows the performance of the NH₃ amplifier in the 11 μm region to be characterized. Small-signal gain coefficients of >10%/cm are measured on the aQ(3,3) transition at 10.8 μm, while pump conversion efficiencies of ~50% are shown to occur under saturation conditions. The NH₃ laser system is described by a rate-equation model, which is validated by comparison with experiment over a wide range of operating conditions. Measurements are made for NH₃ concentrations ranging from 0.05 to 0.2%, for Ar, N₂ and He buffer gas pressures from 170 to 700 Torr, and for gas temperatures from 200 to 300 K. Optically pumped NH₃ is shown to be a versatile and efficient system for the amplification of mid-infrared radiation. The rate-equation model is used to aid in the design of a simple and efficient NH₃ laser. This laser is tuned over more than 70 vibrational band transitions between 10.08 and 14.14 μm. Output energies greater than 1 J per pulse are achieved on several of the strongest lines. In a non-selective cavity an energy conversion efficiency of greater than 35% is obtained with a maximum output energy of 4.6 J. Optically pumped NH₃ is shown to be a flexible and efficient system for the downconversion of CO₂ radiation to the 10-14 μm region. In other experiments, it is shown that optically pumped high pressure mixtures of NH₃ in N₂ are efficient, broadband amplifiers of pulsed CO₂ radiation. In a dilute NH₃ mixture at 6 atmospheres and 200 K, a single pass gain of 150 (21.8 dB) is measured for the 10P(34)CO₂ transition. Gain is observed in NH₃ at pressures as high as 10 atmospheres. Experimental measurements are made for a range of wavelengths in the 10.7 μm region, and the results compared with calculations based on a simplified rate-equation model. The operation of a two-step optically pumped NH₃ laser (using two CO₂ lasers) is examined. Output is obtained from 16-22 μm. Experimental measurements made at 200 K and 300 K are compared to calculations based on an extended rate-equation model. As a result of this work it was shown that a single CO₂ pump laser can be used to obtain 16-22 μm lasing at 200 K.</p>","abstract_html":"&lt;p&gt;An experimental and theoretical study of the dynamics of NH₃ lasers is presented. The significant achievements of this work are summarized below. In initial experiments, a pulsed transversely-excited CO₂ laser operating on the 9R(30) transition is used to optically pump mixtures of NH₃ in buffer gas. A simple oscillator/amplifier system allows the performance of the NH₃ amplifier in the 11 μm region to be characterized. Small-signal gain coefficients of &gt;10%/cm are measured on the aQ(3,3) transition at 10.8 μm, while pump conversion efficiencies of ~50% are shown to occur under saturation conditions. The NH₃ laser system is described by a rate-equation model, which is validated by comparison with experiment over a wide range of operating conditions. Measurements are made for NH₃ concentrations ranging from 0.05 to 0.2%, for Ar, N₂ and He buffer gas pressures from 170 to 700 Torr, and for gas temperatures from 200 to 300 K. Optically pumped NH₃ is shown to be a versatile and efficient system for the amplification of mid-infrared radiation. The rate-equation model is used to aid in the design of a simple and efficient NH₃ laser. This laser is tuned over more than 70 vibrational band transitions between 10.08 and 14.14 μm. Output energies greater than 1 J per pulse are achieved on several of the strongest lines. In a non-selective cavity an energy conversion efficiency of greater than 35% is obtained with a maximum output energy of 4.6 J. Optically pumped NH₃ is shown to be a flexible and efficient system for the downconversion of CO₂ radiation to the 10-14 μm region. In other experiments, it is shown that optically pumped high pressure mixtures of NH₃ in N₂ are efficient, broadband amplifiers of pulsed CO₂ radiation. In a dilute NH₃ mixture at 6 atmospheres and 200 K, a single pass gain of 150 (21.8 dB) is measured for the 10P(34)CO₂ transition. Gain is observed in NH₃ at pressures as high as 10 atmospheres. Experimental measurements are made for a range of wavelengths in the 10.7 μm region, and the results compared with calculations based on a simplified rate-equation model. The operation of a two-step optically pumped NH₃ laser (using two CO₂ lasers) is examined. Output is obtained from 16-22 μm. Experimental measurements made at 200 K and 300 K are compared to calculations based on an extended rate-equation model. As a result of this work it was shown that a single CO₂ pump laser can be used to obtain 16-22 μm lasing at 200 K.&lt;/p&gt;","abstract_has_math":false,"creators":["White, David Jonathon"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Engineering Physics","school":null,"contributors":[],"advisors":["Reid, J."],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-11-18T19:33:58Z","subjects":["Engineering Physics","Nuclear Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/15495"],"render_values":[{"text":"https://doi.org/10.71548/15495","href":"https://doi.org/10.71548/15495","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/3540","4557","1662362"],"render_values":[{"text":"opendissertations/3540","href":null,"code":true},{"text":"4557","href":null,"code":true},{"text":"1662362","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/8327","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/8327","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F8327","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Reid, J."]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Physics"]},{"key":"dc:creator","label":"Author","values":["White, David Jonathon"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T16:42:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-18T16:42:33Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2010-11-25"]},{"key":"dc:date.issued","label":"Date","values":["1991"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering Physics","Nuclear Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/3540","4557","1662362"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/8327","https://doi.org/10.71548/15495"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>An experimental and theoretical study of the dynamics of NH₃ lasers is presented. The significant achievements of this work are summarized below. In initial experiments, a pulsed transversely-excited CO₂ laser operating on the 9R(30) transition is used to optically pump mixtures of NH₃ in buffer gas. A simple oscillator/amplifier system allows the performance of the NH₃ amplifier in the 11 μm region to be characterized. Small-signal gain coefficients of >10%/cm are measured on the aQ(3,3) transition at 10.8 μm, while pump conversion efficiencies of ~50% are shown to occur under saturation conditions. The NH₃ laser system is described by a rate-equation model, which is validated by comparison with experiment over a wide range of operating conditions. Measurements are made for NH₃ concentrations ranging from 0.05 to 0.2%, for Ar, N₂ and He buffer gas pressures from 170 to 700 Torr, and for gas temperatures from 200 to 300 K. Optically pumped NH₃ is shown to be a versatile and efficient system for the amplification of mid-infrared radiation. The rate-equation model is used to aid in the design of a simple and efficient NH₃ laser. This laser is tuned over more than 70 vibrational band transitions between 10.08 and 14.14 μm. Output energies greater than 1 J per pulse are achieved on several of the strongest lines. In a non-selective cavity an energy conversion efficiency of greater than 35% is obtained with a maximum output energy of 4.6 J. Optically pumped NH₃ is shown to be a flexible and efficient system for the downconversion of CO₂ radiation to the 10-14 μm region. In other experiments, it is shown that optically pumped high pressure mixtures of NH₃ in N₂ are efficient, broadband amplifiers of pulsed CO₂ radiation. In a dilute NH₃ mixture at 6 atmospheres and 200 K, a single pass gain of 150 (21.8 dB) is measured for the 10P(34)CO₂ transition. Gain is observed in NH₃ at pressures as high as 10 atmospheres. Experimental measurements are made for a range of wavelengths in the 10.7 μm region, and the results compared with calculations based on a simplified rate-equation model. The operation of a two-step optically pumped NH₃ laser (using two CO₂ lasers) is examined. Output is obtained from 16-22 μm. Experimental measurements made at 200 K and 300 K are compared to calculations based on an extended rate-equation model. As a result of this work it was shown that a single CO₂ pump laser can be used to obtain 16-22 μm lasing at 200 K.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy (PhD)"]},{"key":"dc:title","label":"Title","values":["Dynamics of the ammonia laser"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Reid, J."],"dc:contributor.department":["Engineering Physics"],"dc:creator":["White, David Jonathon"],"dc:date.accessioned":["2014-06-18T16:42:33Z"],"dc:date.available":["2014-06-18T16:42:33Z"],"dc:date.created":["2010-11-25"],"dc:date.issued":["1991"],"dc:description.abstract":["<p>An experimental and theoretical study of the dynamics of NH₃ lasers is presented. The significant achievements of this work are summarized below. In initial experiments, a pulsed transversely-excited CO₂ laser operating on the 9R(30) transition is used to optically pump mixtures of NH₃ in buffer gas. A simple oscillator/amplifier system allows the performance of the NH₃ amplifier in the 11 μm region to be characterized. Small-signal gain coefficients of >10%/cm are measured on the aQ(3,3) transition at 10.8 μm, while pump conversion efficiencies of ~50% are shown to occur under saturation conditions. The NH₃ laser system is described by a rate-equation model, which is validated by comparison with experiment over a wide range of operating conditions. Measurements are made for NH₃ concentrations ranging from 0.05 to 0.2%, for Ar, N₂ and He buffer gas pressures from 170 to 700 Torr, and for gas temperatures from 200 to 300 K. Optically pumped NH₃ is shown to be a versatile and efficient system for the amplification of mid-infrared radiation. The rate-equation model is used to aid in the design of a simple and efficient NH₃ laser. This laser is tuned over more than 70 vibrational band transitions between 10.08 and 14.14 μm. Output energies greater than 1 J per pulse are achieved on several of the strongest lines. In a non-selective cavity an energy conversion efficiency of greater than 35% is obtained with a maximum output energy of 4.6 J. Optically pumped NH₃ is shown to be a flexible and efficient system for the downconversion of CO₂ radiation to the 10-14 μm region. In other experiments, it is shown that optically pumped high pressure mixtures of NH₃ in N₂ are efficient, broadband amplifiers of pulsed CO₂ radiation. In a dilute NH₃ mixture at 6 atmospheres and 200 K, a single pass gain of 150 (21.8 dB) is measured for the 10P(34)CO₂ transition. Gain is observed in NH₃ at pressures as high as 10 atmospheres. Experimental measurements are made for a range of wavelengths in the 10.7 μm region, and the results compared with calculations based on a simplified rate-equation model. The operation of a two-step optically pumped NH₃ laser (using two CO₂ lasers) is examined. Output is obtained from 16-22 μm. Experimental measurements made at 200 K and 300 K are compared to calculations based on an extended rate-equation model. As a result of this work it was shown that a single CO₂ pump laser can be used to obtain 16-22 μm lasing at 200 K.</p>"],"dc:description.degree":["Doctor of Philosophy (PhD)"],"dc:identifier.other":["opendissertations/3540","4557","1662362"],"dc:identifier.uri":["http://hdl.handle.net/11375/8327","https://doi.org/10.71548/15495"],"dc:subject":["Engineering Physics","Nuclear Engineering"],"dc:title":["Dynamics of the ammonia laser"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:33:58Z"}