{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/8419"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/8419","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Electron-Beam Gun System for Electron-Capture Rate-Coefficient Measurement","abstract":"<p>A simple, pulsed, relativistic electron-beam gun has been built to measure electron attachment rates. The high voltage pulse (100KV) is provided by a spiral generator initially charged to 10KV. The electron-beam is formed by a lead (Pb) cathode vacuum-diode. The resulting electron-beam pulse has an energy of 90KeV per electron, a peak current density at the anode center of 175 A/cm², and a duration of 12 ns (FWHM).</p> <p>The electron-beam is injected through a 26-μm thick aluminum foil into a gas mixture located in an electric field. By placing suitable screens in front of the beam, the injected electron-beam current-density is reduced to 1-2 A/cm². This results in an electron density in the plasma (produced by the primary electrons injected in an atmospheric-pressure gas mixture) which is typically 10¹³ cm⁻³. The electric field applied across the plasma is maintained constant (within 0.2%) by means of a storage capacitor (1μF). Rate coefficients of electron-capture reactions are determined by observing the temporal evolution of the induced discharge current pulse.</p> <p>The system was used to measure electron dissociative-attachment rate coefficient for HCl as a function of the reduced field E/N, in both Ar-HCl and Ar-N₂-HCl mixtures. These coefficients are 6.45±0.95 x 10⁻¹¹ cm³ s⁻¹ in Ar-HCl (99:1) and 2. 59±.25 x 10⁻¹⁰cm³ s⁻¹ in Ar-N₂-HCl (35: 64:1), for E/N 10⁻²⁰V.m². From these measurements, and from the use of a numerical solution of the Boltzmann equation for electrons, we have calibrated the relative electron dissociative-attachment cross-section measured by Abouaf and Teillet-Billy. The peak values that give the best fit to our data are 9.4 x 10⁻¹⁹ cm² for Ar-HCl and 18.0 x 10⁻¹⁹ cm² for Ar-N₂-HCl.</p>","abstract_html":"&lt;p&gt;A simple, pulsed, relativistic electron-beam gun has been built to measure electron attachment rates. The high voltage pulse (100KV) is provided by a spiral generator initially charged to 10KV. The electron-beam is formed by a lead (Pb) cathode vacuum-diode. The resulting electron-beam pulse has an energy of 90KeV per electron, a peak current density at the anode center of 175 A/cm², and a duration of 12 ns (FWHM).&lt;/p&gt; &lt;p&gt;The electron-beam is injected through a 26-μm thick aluminum foil into a gas mixture located in an electric field. By placing suitable screens in front of the beam, the injected electron-beam current-density is reduced to 1-2 A/cm². This results in an electron density in the plasma (produced by the primary electrons injected in an atmospheric-pressure gas mixture) which is typically 10¹³ cm⁻³. The electric field applied across the plasma is maintained constant (within 0.2%) by means of a storage capacitor (1μF). Rate coefficients of electron-capture reactions are determined by observing the temporal evolution of the induced discharge current pulse.&lt;/p&gt; &lt;p&gt;The system was used to measure electron dissociative-attachment rate coefficient for HCl as a function of the reduced field E/N, in both Ar-HCl and Ar-N₂-HCl mixtures. These coefficients are 6.45±0.95 x 10⁻¹¹ cm³ s⁻¹ in Ar-HCl (99:1) and 2. 59±.25 x 10⁻¹⁰cm³ s⁻¹ in Ar-N₂-HCl (35: 64:1), for E/N 10⁻²⁰V.m². From these measurements, and from the use of a numerical solution of the Boltzmann equation for electrons, we have calibrated the relative electron dissociative-attachment cross-section measured by Abouaf and Teillet-Billy. The peak values that give the best fit to our data are 9.4 x 10⁻¹⁹ cm² for Ar-HCl and 18.0 x 10⁻¹⁹ cm² for Ar-N₂-HCl.&lt;/p&gt;","abstract_has_math":false,"creators":["Olivier, Marc"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Physics","school":null,"contributors":[],"advisors":["Ballik, E.A."],"committee_chairs":[],"committee_members":[],"year":1980,"date_issued":"1980-09","date_published":"1980-09","updated_at":"2026-11-18T19:38:38Z","subjects":["Physics"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/21558"],"render_values":[{"text":"https://doi.org/10.71548/21558","href":"https://doi.org/10.71548/21558","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/3626","4643","1671348"],"render_values":[{"text":"opendissertations/3626","href":null,"code":true},{"text":"4643","href":null,"code":true},{"text":"1671348","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/8419","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/8419","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F8419","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ballik, E.A."]},{"key":"dc:contributor.department","label":"Department","values":["Physics"]},{"key":"dc:creator","label":"Author","values":["Olivier, Marc"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T16:42:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-18T16:42:51Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2010-12-05"]},{"key":"dc:date.issued","label":"Date","values":["1980-09"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/3626","4643","1671348"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/8419","https://doi.org/10.71548/21558"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>A simple, pulsed, relativistic electron-beam gun has been built to measure electron attachment rates. The high voltage pulse (100KV) is provided by a spiral generator initially charged to 10KV. The electron-beam is formed by a lead (Pb) cathode vacuum-diode. The resulting electron-beam pulse has an energy of 90KeV per electron, a peak current density at the anode center of 175 A/cm², and a duration of 12 ns (FWHM).</p> <p>The electron-beam is injected through a 26-μm thick aluminum foil into a gas mixture located in an electric field. By placing suitable screens in front of the beam, the injected electron-beam current-density is reduced to 1-2 A/cm². This results in an electron density in the plasma (produced by the primary electrons injected in an atmospheric-pressure gas mixture) which is typically 10¹³ cm⁻³. The electric field applied across the plasma is maintained constant (within 0.2%) by means of a storage capacitor (1μF). Rate coefficients of electron-capture reactions are determined by observing the temporal evolution of the induced discharge current pulse.</p> <p>The system was used to measure electron dissociative-attachment rate coefficient for HCl as a function of the reduced field E/N, in both Ar-HCl and Ar-N₂-HCl mixtures. These coefficients are 6.45±0.95 x 10⁻¹¹ cm³ s⁻¹ in Ar-HCl (99:1) and 2. 59±.25 x 10⁻¹⁰cm³ s⁻¹ in Ar-N₂-HCl (35: 64:1), for E/N 10⁻²⁰V.m². From these measurements, and from the use of a numerical solution of the Boltzmann equation for electrons, we have calibrated the relative electron dissociative-attachment cross-section measured by Abouaf and Teillet-Billy. The peak values that give the best fit to our data are 9.4 x 10⁻¹⁹ cm² for Ar-HCl and 18.0 x 10⁻¹⁹ cm² for Ar-N₂-HCl.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science (MS)"]},{"key":"dc:title","label":"Title","values":["Electron-Beam Gun System for Electron-Capture Rate-Coefficient Measurement"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Ballik, E.A."],"dc:contributor.department":["Physics"],"dc:creator":["Olivier, Marc"],"dc:date.accessioned":["2014-06-18T16:42:51Z"],"dc:date.available":["2014-06-18T16:42:51Z"],"dc:date.created":["2010-12-05"],"dc:date.issued":["1980-09"],"dc:description.abstract":["<p>A simple, pulsed, relativistic electron-beam gun has been built to measure electron attachment rates. The high voltage pulse (100KV) is provided by a spiral generator initially charged to 10KV. The electron-beam is formed by a lead (Pb) cathode vacuum-diode. The resulting electron-beam pulse has an energy of 90KeV per electron, a peak current density at the anode center of 175 A/cm², and a duration of 12 ns (FWHM).</p> <p>The electron-beam is injected through a 26-μm thick aluminum foil into a gas mixture located in an electric field. By placing suitable screens in front of the beam, the injected electron-beam current-density is reduced to 1-2 A/cm². This results in an electron density in the plasma (produced by the primary electrons injected in an atmospheric-pressure gas mixture) which is typically 10¹³ cm⁻³. The electric field applied across the plasma is maintained constant (within 0.2%) by means of a storage capacitor (1μF). Rate coefficients of electron-capture reactions are determined by observing the temporal evolution of the induced discharge current pulse.</p> <p>The system was used to measure electron dissociative-attachment rate coefficient for HCl as a function of the reduced field E/N, in both Ar-HCl and Ar-N₂-HCl mixtures. These coefficients are 6.45±0.95 x 10⁻¹¹ cm³ s⁻¹ in Ar-HCl (99:1) and 2. 59±.25 x 10⁻¹⁰cm³ s⁻¹ in Ar-N₂-HCl (35: 64:1), for E/N 10⁻²⁰V.m². From these measurements, and from the use of a numerical solution of the Boltzmann equation for electrons, we have calibrated the relative electron dissociative-attachment cross-section measured by Abouaf and Teillet-Billy. The peak values that give the best fit to our data are 9.4 x 10⁻¹⁹ cm² for Ar-HCl and 18.0 x 10⁻¹⁹ cm² for Ar-N₂-HCl.</p>"],"dc:description.degree":["Master of Science (MS)"],"dc:identifier.other":["opendissertations/3626","4643","1671348"],"dc:identifier.uri":["http://hdl.handle.net/11375/8419","https://doi.org/10.71548/21558"],"dc:subject":["Physics"],"dc:title":["Electron-Beam Gun System for Electron-Capture Rate-Coefficient Measurement"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:38:38Z"}