{"id":{"repo_id":"mcmaster","oai_identifier":"oai:macsphere.mcmaster.ca:11375/8958"},"canonical_url":"https://search.ndltd.org/etd/mcmaster/oai:macsphere.mcmaster.ca:11375/8958","repository":{"repo_id":"mcmaster","name":"McMaster University","base_url":"https://macsphere.mcmaster.ca/server/oai/request"},"display":{"title":"Development of Paper-based Devices for Diagnostics and Biosensing","abstract":"<p>Research in paper-based analytical devices has been increasing rapidly in recent years. Manyof these devices are used as low-cost alternatives for diagnostics and biosensing. In this work,two novel paper-based technologies were developed.</p> <p>The first paper-based technology achieved was measuring streaming potential on paper-based microfluidic devices. The streaming potential measurements were able to detect the presence of adsorbed polyvinylamine or potassium polyvinylsulfate in paper-based microfluidic channels.</p> <p>The measured streaming potential ranged from -80 mV to 80 mV and the polarity was sensitive to the adsorbed polymer. Furthermore, the measured streaming potential on paper treated with BSA showed a polarity switch when the pH was changed from below the pKa to above the pKa of BSA. Lastly, streaming potential measurements may provide an electronic interface for paperbased sensors.</p> <p>The second technology developed was a paper-based chromatographic pre-concentration device for biological and chemical applications. The device successfully concentrated a protein, streptavidin, via biotinylated microgels immobilized onto a selected area of the filter paper. The device was able to process a large volume of fluid with the incorporation of a passive pump made of superabsorbent polymer. The concentration factor achieved by the device was over 3000-fold. The flow dynamics through the paper was modeled using Darcy’s law. This technology could be an excellent low-cost alternative for biochemical analysis for samples thatrequire preconcentration, especially for the analysis of trace compounds in wastewater and drinking water.</p>","abstract_html":"&lt;p&gt;Research in paper-based analytical devices has been increasing rapidly in recent years. Manyof these devices are used as low-cost alternatives for diagnostics and biosensing. In this work,two novel paper-based technologies were developed.&lt;/p&gt; &lt;p&gt;The first paper-based technology achieved was measuring streaming potential on paper-based microfluidic devices. The streaming potential measurements were able to detect the presence of adsorbed polyvinylamine or potassium polyvinylsulfate in paper-based microfluidic channels.&lt;/p&gt; &lt;p&gt;The measured streaming potential ranged from -80 mV to 80 mV and the polarity was sensitive to the adsorbed polymer. Furthermore, the measured streaming potential on paper treated with BSA showed a polarity switch when the pH was changed from below the pKa to above the pKa of BSA. Lastly, streaming potential measurements may provide an electronic interface for paperbased sensors.&lt;/p&gt; &lt;p&gt;The second technology developed was a paper-based chromatographic pre-concentration device for biological and chemical applications. The device successfully concentrated a protein, streptavidin, via biotinylated microgels immobilized onto a selected area of the filter paper. The device was able to process a large volume of fluid with the incorporation of a passive pump made of superabsorbent polymer. The concentration factor achieved by the device was over 3000-fold. The flow dynamics through the paper was modeled using Darcy’s law. This technology could be an excellent low-cost alternative for biochemical analysis for samples thatrequire preconcentration, especially for the analysis of trace compounds in wastewater and drinking water.&lt;/p&gt;","abstract_has_math":false,"creators":["Leung, Vincent"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":["Filipe, Carlos","Pelton, Robert","Dr. Todd Hoare and Dr. Emily Cranston"],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-10","date_published":"2011-10","updated_at":"2026-11-18T19:33:08Z","subjects":["Paper-based devices","microfluidics","biosensors","diagnostics","Other Chemical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://doi.org/10.71548/13442"],"render_values":[{"text":"https://doi.org/10.71548/13442","href":"https://doi.org/10.71548/13442","code":true}]},{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/4123","5123","2014937"],"render_values":[{"text":"opendissertations/4123","href":null,"code":true},{"text":"5123","href":null,"code":true},{"text":"2014937","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11375/8958","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11375/8958","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://macsphere.mcmaster.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amacsphere.mcmaster.ca%3A11375%2F8958","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Filipe, Carlos","Pelton, Robert","Dr. Todd Hoare and Dr. Emily Cranston"]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Leung, Vincent"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-06-18T16:44:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-18T16:44:50Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2011-05-16"]},{"key":"dc:date.issued","label":"Date","values":["2011-10"]},{"key":"dc:type","label":"Dc Type","values":["thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Paper-based devices","microfluidics","biosensors","diagnostics","Other Chemical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["opendissertations/4123","5123","2014937"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11375/8958","https://doi.org/10.71548/13442"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["<p>Research in paper-based analytical devices has been increasing rapidly in recent years. Manyof these devices are used as low-cost alternatives for diagnostics and biosensing. In this work,two novel paper-based technologies were developed.</p> <p>The first paper-based technology achieved was measuring streaming potential on paper-based microfluidic devices. The streaming potential measurements were able to detect the presence of adsorbed polyvinylamine or potassium polyvinylsulfate in paper-based microfluidic channels.</p> <p>The measured streaming potential ranged from -80 mV to 80 mV and the polarity was sensitive to the adsorbed polymer. Furthermore, the measured streaming potential on paper treated with BSA showed a polarity switch when the pH was changed from below the pKa to above the pKa of BSA. Lastly, streaming potential measurements may provide an electronic interface for paperbased sensors.</p> <p>The second technology developed was a paper-based chromatographic pre-concentration device for biological and chemical applications. The device successfully concentrated a protein, streptavidin, via biotinylated microgels immobilized onto a selected area of the filter paper. The device was able to process a large volume of fluid with the incorporation of a passive pump made of superabsorbent polymer. The concentration factor achieved by the device was over 3000-fold. The flow dynamics through the paper was modeled using Darcy’s law. This technology could be an excellent low-cost alternative for biochemical analysis for samples thatrequire preconcentration, especially for the analysis of trace compounds in wastewater and drinking water.</p>"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Applied Science (MASc)"]},{"key":"dc:title","label":"Title","values":["Development of Paper-based Devices for Diagnostics and Biosensing"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Filipe, Carlos","Pelton, Robert","Dr. Todd Hoare and Dr. Emily Cranston"],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Leung, Vincent"],"dc:date.accessioned":["2014-06-18T16:44:50Z"],"dc:date.available":["2014-06-18T16:44:50Z"],"dc:date.created":["2011-05-16"],"dc:date.issued":["2011-10"],"dc:description.abstract":["<p>Research in paper-based analytical devices has been increasing rapidly in recent years. Manyof these devices are used as low-cost alternatives for diagnostics and biosensing. In this work,two novel paper-based technologies were developed.</p> <p>The first paper-based technology achieved was measuring streaming potential on paper-based microfluidic devices. The streaming potential measurements were able to detect the presence of adsorbed polyvinylamine or potassium polyvinylsulfate in paper-based microfluidic channels.</p> <p>The measured streaming potential ranged from -80 mV to 80 mV and the polarity was sensitive to the adsorbed polymer. Furthermore, the measured streaming potential on paper treated with BSA showed a polarity switch when the pH was changed from below the pKa to above the pKa of BSA. Lastly, streaming potential measurements may provide an electronic interface for paperbased sensors.</p> <p>The second technology developed was a paper-based chromatographic pre-concentration device for biological and chemical applications. The device successfully concentrated a protein, streptavidin, via biotinylated microgels immobilized onto a selected area of the filter paper. The device was able to process a large volume of fluid with the incorporation of a passive pump made of superabsorbent polymer. The concentration factor achieved by the device was over 3000-fold. The flow dynamics through the paper was modeled using Darcy’s law. This technology could be an excellent low-cost alternative for biochemical analysis for samples thatrequire preconcentration, especially for the analysis of trace compounds in wastewater and drinking water.</p>"],"dc:description.degree":["Master of Applied Science (MASc)"],"dc:identifier.other":["opendissertations/4123","5123","2014937"],"dc:identifier.uri":["http://hdl.handle.net/11375/8958","https://doi.org/10.71548/13442"],"dc:subject":["Paper-based devices","microfluidics","biosensors","diagnostics","Other Chemical Engineering"],"dc:title":["Development of Paper-based Devices for Diagnostics and Biosensing"],"dc:type":["thesis"],"others:access_status":["open.access"]},"updated_at":"2026-11-18T19:33:08Z"}