{"id":{"repo_id":"missouri","oai_identifier":"oai:mospace.umsystem.edu:10355/4697"},"canonical_url":"https://search.ndltd.org/etd/missouri/oai:mospace.umsystem.edu:10355/4697","repository":{"repo_id":"missouri","name":"University of Missouri","base_url":"https://mospace.umsystem.edu/oai/request"},"display":{"title":"A study of parametric excitation applied to a MEMS tuning fork gyroscope","abstract":"The current MEMS ( gyroscopes which normally use the electro static force to excite the comb drive are faced with the limitations such as low precision, coupling problem, and poor robustness. We propose to use parametric excitation to solve those problems. The advantage of the parametric excitation is that it can be externalized, thus, the fabrication process can also be simplified. A feasibility study of the parametric excitation using a two-pendulum model is presented. Governing equations are derived by Lagrange equation, and the results are simulated using MATLAB program. Two swing patterns, symmetric and anti-symmetric motion, are illustrated and investigated with different initial conditions. An experimental study of a tuning fork beam is presented. For non-contact motion analysis, an Eagle 3-D motion analysis digital camera system is employed. We discuss the practical problems such as limited shaker power, which is caused by open-loop excitation method. A governing equation including the damping effect by the lateral vibration of the tines is presented, and its analytical solution is compared with the experimental results. A good qualitative agreement is obtained. To clarify the softening nonlinearity of the tuning fork beam, the gravity effect is described for both vertical and inverted pendulum cases.","abstract_html":"The current MEMS ( gyroscopes which normally use the electro static force to excite the comb drive are faced with the limitations such as low precision, coupling problem, and poor robustness. We propose to use parametric excitation to solve those problems. The advantage of the parametric excitation is that it can be externalized, thus, the fabrication process can also be simplified. A feasibility study of the parametric excitation using a two-pendulum model is presented. Governing equations are derived by Lagrange equation, and the results are simulated using MATLAB program. Two swing patterns, symmetric and anti-symmetric motion, are illustrated and investigated with different initial conditions. An experimental study of a tuning fork beam is presented. For non-contact motion analysis, an Eagle 3-D motion analysis digital camera system is employed. We discuss the practical problems such as limited shaker power, which is caused by open-loop excitation method. A governing equation including the damping effect by the lateral vibration of the tines is presented, and its analytical solution is compared with the experimental results. A good qualitative agreement is obtained. To clarify the softening nonlinearity of the tuning fork beam, the gravity effect is described for both vertical and inverted pendulum cases.","abstract_has_math":false,"creators":["Lee, Yongsik, 1970-"],"institution":"University of Missouri--Columbia","degree_name":"Ph. D.","degree_level":"Doctoral","degree_discipline":"Mechanical and aerospace engineering (MU)","degree_department":null,"school":null,"contributors":[],"advisors":["Feng, Zaichun"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-19T09:00:01Z","subjects":["Microelectromechanical systems","Electric machinery -- Excitation systems","Parametric devices"],"languages":["eng","English"],"rights":["OpenAccess."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["182579769"],"render_values":[{"text":"182579769","href":null,"code":true}]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/4697"],"render_values":[{"text":"https://hdl.handle.net/10355/4697","href":"https://hdl.handle.net/10355/4697","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["b61477990"],"render_values":[{"text":"b61477990","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.32469/10355/4697","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.32469/10355/4697","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amissouri%3Aoai%3Amospace.umsystem.edu%3A10355%2F4697","prefix":"oai_dc"},"source_record":{"url":"https://mospace.umsystem.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amospace.umsystem.edu%3A10355%2F4697","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Feng, Zaichun"]},{"key":"dc:creator","label":"Author","values":["Lee, Yongsik, 1970-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-01-12T18:40:36Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-12T18:40:36Z"]},{"key":"dc:date.issued","label":"Date","values":["2007"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2007 Summer"]},{"key":"dc:publisher","label":"Institution","values":["University of Missouri--Columbia"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["University of Missouri--Columbia. Graduate School. Theses and Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and aerospace engineering (MU)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Missouri--Columbia"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Microelectromechanical systems","Electric machinery -- Excitation systems","Parametric devices"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["OpenAccess."]},{"key":"dc:rights.license","label":"Dc Rights License","values":["This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["b61477990"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.32469/10355/4697"]},{"key":"dc:identifier.oclc","label":"OCLC","values":["182579769"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/4697"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file.","Title from title screen of research.pdf file (viewed on November 29, 2007.","Vita.","Thesis (Ph. D.) University of Missouri-Columbia 2007."]},{"key":"dc:description.abstract","label":"Abstract","values":["The current MEMS ( gyroscopes which normally use the electro static force to excite the comb drive are faced with the limitations such as low precision, coupling problem, and poor robustness. We propose to use parametric excitation to solve those problems. The advantage of the parametric excitation is that it can be externalized, thus, the fabrication process can also be simplified. A feasibility study of the parametric excitation using a two-pendulum model is presented. Governing equations are derived by Lagrange equation, and the results are simulated using MATLAB program. Two swing patterns, symmetric and anti-symmetric motion, are illustrated and investigated with different initial conditions. An experimental study of a tuning fork beam is presented. For non-contact motion analysis, an Eagle 3-D motion analysis digital camera system is employed. We discuss the practical problems such as limited shaker power, which is caused by open-loop excitation method. A governing equation including the damping effect by the lateral vibration of the tines is presented, and its analytical solution is compared with the experimental results. A good qualitative agreement is obtained. To clarify the softening nonlinearity of the tuning fork beam, the gravity effect is described for both vertical and inverted pendulum cases."]},{"key":"dc:description.bibliography","label":"Dc Description Bibliography","values":["Includes bibliographical references."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["LeeY-072007-D8161"]},{"key":"dc:title","label":"Title","values":["A study of parametric excitation applied to a MEMS tuning fork gyroscope"]}]}],"canonical_facts":{"dc:contributor.advisor":["Feng, Zaichun"],"dc:creator":["Lee, Yongsik, 1970-"],"dc:date.accessioned":["2010-01-12T18:40:36Z"],"dc:date.available":["2010-01-12T18:40:36Z"],"dc:date.issued":["2007"],"dc:date.submitted":["2007 Summer"],"dc:description":["The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file.","Title from title screen of research.pdf file (viewed on November 29, 2007.","Vita.","Thesis (Ph. D.) University of Missouri-Columbia 2007."],"dc:description.abstract":["The current MEMS ( gyroscopes which normally use the electro static force to excite the comb drive are faced with the limitations such as low precision, coupling problem, and poor robustness. We propose to use parametric excitation to solve those problems. The advantage of the parametric excitation is that it can be externalized, thus, the fabrication process can also be simplified. A feasibility study of the parametric excitation using a two-pendulum model is presented. Governing equations are derived by Lagrange equation, and the results are simulated using MATLAB program. Two swing patterns, symmetric and anti-symmetric motion, are illustrated and investigated with different initial conditions. An experimental study of a tuning fork beam is presented. For non-contact motion analysis, an Eagle 3-D motion analysis digital camera system is employed. We discuss the practical problems such as limited shaker power, which is caused by open-loop excitation method. A governing equation including the damping effect by the lateral vibration of the tines is presented, and its analytical solution is compared with the experimental results. A good qualitative agreement is obtained. To clarify the softening nonlinearity of the tuning fork beam, the gravity effect is described for both vertical and inverted pendulum cases."],"dc:description.bibliography":["Includes bibliographical references."],"dc:description.provenance":["LeeY-072007-D8161"],"dc:identifier.bibid":["b61477990"],"dc:identifier.doi":["https://doi.org/10.32469/10355/4697"],"dc:identifier.oclc":["182579769"],"dc:identifier.uri":["https://hdl.handle.net/10355/4697"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["University of Missouri--Columbia"],"dc:relation.ispartof":["University of Missouri--Columbia. Graduate School. Theses and Dissertations"],"dc:rights":["OpenAccess."],"dc:rights.license":["This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License."],"dc:subject.lcsh":["Microelectromechanical systems","Electric machinery -- Excitation systems","Parametric devices"],"dc:title":["A study of parametric excitation applied to a MEMS tuning fork gyroscope"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical and aerospace engineering (MU)"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["University of Missouri--Columbia"]},"updated_at":"2026-11-19T09:00:01Z"}