{"id":{"repo_id":"missouri","oai_identifier":"oai:mospace.umsystem.edu:10355/6002"},"canonical_url":"https://search.ndltd.org/etd/missouri/oai:mospace.umsystem.edu:10355/6002","repository":{"repo_id":"missouri","name":"University of Missouri","base_url":"https://mospace.umsystem.edu/oai/request"},"display":{"title":"Direct contact heat exchanger development","abstract":"[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The purpose of this work was to develop tools that guide the design of a direct contact heat exchanger for small-scale commercial and/or residential HVAC applications. Experimental data was gathered with a temperature and humidity controlled wind tunnel having a 15 cm square test section that utilized flat-fan water sprays as the working fluid/surface. The data was used to develop an overall sensible heat transfer correlation. A numeric model simulating heat and mass transfer from a water spray was also developed. The correlation was found to accurately capture the fundamental behavior of the system; however, the uncertainty of predicted amount of heat transfer averaged 82%. The numeric model also trended well with the experimental data; however, the model under predicted the heat transfer by an average of 50%. Investigation into the discrepancies revealed information about droplet entrainment in the experimental system and the limiting factors of the correlation and model.","abstract_html":"[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR&#x27;S REQUEST.] The purpose of this work was to develop tools that guide the design of a direct contact heat exchanger for small-scale commercial and/or residential HVAC applications. Experimental data was gathered with a temperature and humidity controlled wind tunnel having a 15 cm square test section that utilized flat-fan water sprays as the working fluid/surface. The data was used to develop an overall sensible heat transfer correlation. A numeric model simulating heat and mass transfer from a water spray was also developed. The correlation was found to accurately capture the fundamental behavior of the system; however, the uncertainty of predicted amount of heat transfer averaged 82%. The numeric model also trended well with the experimental data; however, the model under predicted the heat transfer by an average of 50%. Investigation into the discrepancies revealed information about droplet entrainment in the experimental system and the limiting factors of the correlation and model.","abstract_has_math":false,"creators":["Hensley, Joshua L., 1980-"],"institution":"University of Missouri--Columbia","degree_name":"Ph. D.","degree_level":"Doctoral","degree_discipline":"Mechanical and aerospace engineering (MU)","degree_department":null,"school":null,"contributors":[],"advisors":["Bryan, James E., 1964-"],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-19T08:51:45Z","subjects":["Heat exchangers -- Design and construction","Heat exchangers -- Fluid dynamics"],"languages":["eng","English"],"rights":["Access to files is limited to the campuses of the University of Missouri with SSO login."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["314774050"],"render_values":[{"text":"314774050","href":null,"code":true}]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/6002"],"render_values":[{"text":"https://hdl.handle.net/10355/6002","href":"https://hdl.handle.net/10355/6002","code":true}]},{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["b66640684"],"render_values":[{"text":"b66640684","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.32469/10355/6002","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.32469/10355/6002","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amissouri%3Aoai%3Amospace.umsystem.edu%3A10355%2F6002","prefix":"oai_dc"},"source_record":{"url":"https://mospace.umsystem.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Amospace.umsystem.edu%3A10355%2F6002","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Bryan, James E., 1964-"]},{"key":"dc:creator","label":"Author","values":["Hensley, Joshua L., 1980-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-02-24T19:27:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-02-24T19:27:43Z"]},{"key":"dc:date.issued","label":"Date","values":["2007"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2007 Fall"]},{"key":"dc:publisher","label":"Institution","values":["University of Missouri--Columbia"]},{"key":"dc:relation.ispartof","label":"Dc Relation Ispartof","values":["University of Missouri--Columbia. Graduate School. Theses and Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and aerospace engineering (MU)"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Missouri--Columbia"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Heat exchangers -- Design and construction","Heat exchangers -- Fluid dynamics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Access to files is limited to the campuses of the University of Missouri with SSO login."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.bibid","label":"Dc Identifier Bibid","values":["b66640684"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.32469/10355/6002"]},{"key":"dc:identifier.oclc","label":"OCLC","values":["314774050"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10355/6002"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file.","Title from title screen of research.pdf file (viewed on March 13, 2008)","Vita.","Thesis (Ph. D.) University of Missouri-Columbia 2007."]},{"key":"dc:description.abstract","label":"Abstract","values":["[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The purpose of this work was to develop tools that guide the design of a direct contact heat exchanger for small-scale commercial and/or residential HVAC applications. Experimental data was gathered with a temperature and humidity controlled wind tunnel having a 15 cm square test section that utilized flat-fan water sprays as the working fluid/surface. The data was used to develop an overall sensible heat transfer correlation. A numeric model simulating heat and mass transfer from a water spray was also developed. The correlation was found to accurately capture the fundamental behavior of the system; however, the uncertainty of predicted amount of heat transfer averaged 82%. The numeric model also trended well with the experimental data; however, the model under predicted the heat transfer by an average of 50%. Investigation into the discrepancies revealed information about droplet entrainment in the experimental system and the limiting factors of the correlation and model."]},{"key":"dc:description.bibliography","label":"Dc Description Bibliography","values":["Includes bibliographical references."]},{"key":"dc:description.provenance","label":"Dc Description Provenance","values":["HensleyJ-030509-D8952"]},{"key":"dc:title","label":"Title","values":["Direct contact heat exchanger development"]}]}],"canonical_facts":{"dc:contributor.advisor":["Bryan, James E., 1964-"],"dc:creator":["Hensley, Joshua L., 1980-"],"dc:date.accessioned":["2010-02-24T19:27:43Z"],"dc:date.available":["2010-02-24T19:27:43Z"],"dc:date.issued":["2007"],"dc:date.submitted":["2007 Fall"],"dc:description":["The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file.","Title from title screen of research.pdf file (viewed on March 13, 2008)","Vita.","Thesis (Ph. D.) University of Missouri-Columbia 2007."],"dc:description.abstract":["[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The purpose of this work was to develop tools that guide the design of a direct contact heat exchanger for small-scale commercial and/or residential HVAC applications. Experimental data was gathered with a temperature and humidity controlled wind tunnel having a 15 cm square test section that utilized flat-fan water sprays as the working fluid/surface. The data was used to develop an overall sensible heat transfer correlation. A numeric model simulating heat and mass transfer from a water spray was also developed. The correlation was found to accurately capture the fundamental behavior of the system; however, the uncertainty of predicted amount of heat transfer averaged 82%. The numeric model also trended well with the experimental data; however, the model under predicted the heat transfer by an average of 50%. Investigation into the discrepancies revealed information about droplet entrainment in the experimental system and the limiting factors of the correlation and model."],"dc:description.bibliography":["Includes bibliographical references."],"dc:description.provenance":["HensleyJ-030509-D8952"],"dc:identifier.bibid":["b66640684"],"dc:identifier.doi":["https://doi.org/10.32469/10355/6002"],"dc:identifier.oclc":["314774050"],"dc:identifier.uri":["https://hdl.handle.net/10355/6002"],"dc:language":["English"],"dc:language.iso":["eng"],"dc:publisher":["University of Missouri--Columbia"],"dc:relation.ispartof":["University of Missouri--Columbia. Graduate School. Theses and Dissertations"],"dc:rights":["Access to files is limited to the campuses of the University of Missouri with SSO login."],"dc:subject.lcsh":["Heat exchangers -- Design and construction","Heat exchangers -- Fluid dynamics"],"dc:title":["Direct contact heat exchanger development"],"dc:type":["Thesis"],"thesis:degree_discipline":["Mechanical and aerospace engineering (MU)"],"thesis:degree_level":["Doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["University of Missouri--Columbia"]},"updated_at":"2026-11-19T08:51:45Z"}