{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/106718"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/106718","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Detecting cervical dysplasia with quantitative spectroscopic imaging","abstract":"This thesis extends quantitative spectroscopy, a form of model-based reflectance and fluorescence spectroscopy, from a small area, contact-probe implementation to wide-area quantitative spectroscopic imaging (QSI) for complete coverage of at-risk tissue. QSI uses the scanning virtual probe concept that is critical for model-based spectroscopy and offers spatial resolution advantages over conventional wide-field illumination. We develop a QSI system capable of imaging cervical dysplasia in vivo. Using the QSI system, we conduct a clinical study to train and prospectively evaluate QSI's ability to distinguish high-grade squamous intraepithelial lesions (HSIL) from non-HSILs (less severe conditions) in cervical transformation zone. This is a clinically important distinction because HSIL requires treatment. The results show measuring the per-patient normalized reduced scattering coefficient alone accurately performs the distinction. This is in good agreement with our previous contact-probe study of HSIL. Due to improved accuracy, QSI used as an adjunct to colposcopy can potentially reduce the number of unnecessary biopsies over colposcopy alone. The results also suggest a simplified optical instrument can be used to detect HSIL and this may advance cervical dysplasia detection in developing countries, where cervical cancer mortality is highest.","abstract_html":"This thesis extends quantitative spectroscopy, a form of model-based reflectance and fluorescence spectroscopy, from a small area, contact-probe implementation to wide-area quantitative spectroscopic imaging (QSI) for complete coverage of at-risk tissue. QSI uses the scanning virtual probe concept that is critical for model-based spectroscopy and offers spatial resolution advantages over conventional wide-field illumination. We develop a QSI system capable of imaging cervical dysplasia in vivo. Using the QSI system, we conduct a clinical study to train and prospectively evaluate QSI&#x27;s ability to distinguish high-grade squamous intraepithelial lesions (HSIL) from non-HSILs (less severe conditions) in cervical transformation zone. This is a clinically important distinction because HSIL requires treatment. The results show measuring the per-patient normalized reduced scattering coefficient alone accurately performs the distinction. This is in good agreement with our previous contact-probe study of HSIL. Due to improved accuracy, QSI used as an adjunct to colposcopy can potentially reduce the number of unnecessary biopsies over colposcopy alone. The results also suggest a simplified optical instrument can be used to detect HSIL and this may advance cervical dysplasia detection in developing countries, where cervical cancer mortality is highest.","abstract_has_math":false,"creators":["Lau, Condon"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Michael Feld."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-29T16:53:01Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["457047449"],"render_values":[{"text":"457047449","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/106718","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/106718","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F106718","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F106718","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Michael Feld."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Lau, Condon"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-01-30T19:15:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-01-30T19:15:18Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["457047449"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/106718"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"90923c0d-668d-46ba-a7fe-8b855540fa2b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Detecting cervical dysplasia with quantitative spectroscopic imaging</Title> <Subtitle>Detecting cervical dysplasia with QSI</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Lau, Condon</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>This thesis extends quantitative spectroscopy, a form of model-based reflectance and fluorescence spectroscopy, from a small area, contact-probe implementation to wide-area quantitative spectroscopic imaging (QSI) for complete coverage of at-risk tissue. QSI uses the scanning virtual probe concept that is critical for model-based spectroscopy and offers spatial resolution advantages over conventional wide-field illumination. We develop a QSI system capable of imaging cervical dysplasia in vivo. Using the QSI system, we conduct a clinical study to train and prospectively evaluate QSI's ability to distinguish high-grade squamous intraepithelial lesions (HSIL) from non-HSILs (less severe conditions) in cervical transformation zone. This is a clinically important distinction because HSIL requires treatment. The results show measuring the per-patient normalized reduced scattering coefficient alone accurately performs the distinction. This is in good agreement with our previous contact-probe study of HSIL. Due to improved accuracy, QSI used as an adjunct to colposcopy can potentially reduce the number of unnecessary biopsies over colposcopy alone. The results also suggest a simplified optical instrument can be used to detect HSIL and this may advance cervical dysplasia detection in developing countries, where cervical cancer mortality is highest.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.","Includes bibliographical references."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis extends quantitative spectroscopy, a form of model-based reflectance and fluorescence spectroscopy, from a small area, contact-probe implementation to wide-area quantitative spectroscopic imaging (QSI) for complete coverage of at-risk tissue. QSI uses the scanning virtual probe concept that is critical for model-based spectroscopy and offers spatial resolution advantages over conventional wide-field illumination. We develop a QSI system capable of imaging cervical dysplasia in vivo. Using the QSI system, we conduct a clinical study to train and prospectively evaluate QSI's ability to distinguish high-grade squamous intraepithelial lesions (HSIL) from non-HSILs (less severe conditions) in cervical transformation zone. This is a clinically important distinction because HSIL requires treatment. The results show measuring the per-patient normalized reduced scattering coefficient alone accurately performs the distinction. This is in good agreement with our previous contact-probe study of HSIL. Due to improved accuracy, QSI used as an adjunct to colposcopy can potentially reduce the number of unnecessary biopsies over colposcopy alone. The results also suggest a simplified optical instrument can be used to detect HSIL and this may advance cervical dysplasia detection in developing countries, where cervical cancer mortality is highest."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Condon Lau."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["146 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Detecting cervical dysplasia with quantitative spectroscopic imaging"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Detecting cervical dysplasia with QSI"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"90923c0d-668d-46ba-a7fe-8b855540fa2b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Detecting cervical dysplasia with quantitative spectroscopic imaging</Title> <Subtitle>Detecting cervical dysplasia with QSI</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Lau, Condon</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>This thesis extends quantitative spectroscopy, a form of model-based reflectance and fluorescence spectroscopy, from a small area, contact-probe implementation to wide-area quantitative spectroscopic imaging (QSI) for complete coverage of at-risk tissue. QSI uses the scanning virtual probe concept that is critical for model-based spectroscopy and offers spatial resolution advantages over conventional wide-field illumination. We develop a QSI system capable of imaging cervical dysplasia in vivo. Using the QSI system, we conduct a clinical study to train and prospectively evaluate QSI's ability to distinguish high-grade squamous intraepithelial lesions (HSIL) from non-HSILs (less severe conditions) in cervical transformation zone. This is a clinically important distinction because HSIL requires treatment. The results show measuring the per-patient normalized reduced scattering coefficient alone accurately performs the distinction. This is in good agreement with our previous contact-probe study of HSIL. Due to improved accuracy, QSI used as an adjunct to colposcopy can potentially reduce the number of unnecessary biopsies over colposcopy alone. The results also suggest a simplified optical instrument can be used to detect HSIL and this may advance cervical dysplasia detection in developing countries, where cervical cancer mortality is highest.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Michael Feld."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Mechanical Engineering."],"dc:creator":["Lau, Condon"],"dc:date.accessioned":["2017-01-30T19:15:18Z"],"dc:date.available":["2017-01-30T19:15:18Z"],"dc:date.copyright":["2009"],"dc:date.issued":["2009"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.","Includes bibliographical references."],"dc:description.abstract":["This thesis extends quantitative spectroscopy, a form of model-based reflectance and fluorescence spectroscopy, from a small area, contact-probe implementation to wide-area quantitative spectroscopic imaging (QSI) for complete coverage of at-risk tissue. QSI uses the scanning virtual probe concept that is critical for model-based spectroscopy and offers spatial resolution advantages over conventional wide-field illumination. We develop a QSI system capable of imaging cervical dysplasia in vivo. Using the QSI system, we conduct a clinical study to train and prospectively evaluate QSI's ability to distinguish high-grade squamous intraepithelial lesions (HSIL) from non-HSILs (less severe conditions) in cervical transformation zone. This is a clinically important distinction because HSIL requires treatment. The results show measuring the per-patient normalized reduced scattering coefficient alone accurately performs the distinction. This is in good agreement with our previous contact-probe study of HSIL. Due to improved accuracy, QSI used as an adjunct to colposcopy can potentially reduce the number of unnecessary biopsies over colposcopy alone. The results also suggest a simplified optical instrument can be used to detect HSIL and this may advance cervical dysplasia detection in developing countries, where cervical cancer mortality is highest."],"dc:description.degree":["Ph.D."],"dc:description.statementofresponsibility":["by Condon Lau."],"dc:format.extent":["146 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["457047449"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/106718"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Detecting cervical dysplasia with quantitative spectroscopic imaging"],"dc:title.alternative":["Detecting cervical dysplasia with QSI"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-29T16:53:01Z"}