{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/123284"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/123284","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Autonomous active ankle exo-skeleton devices provide metabolic cost reduction","abstract":"In this thesis, I designed and conducted an experiment that looks to confirm the metabolic cost decrease associated with the usage of an autonomous active ankle exoskeleton. The primary method to identify the associated metabolic costs was through the comparison of cardiovascular and respiratory activity during gait with and without the use of the exoskeleton. Rates of oxygen consumption, carbon dioxide production, and pulse were recorded for both control and experimental trials. Using these physiological responses, associated energy expenditure rates were calculated. The results of these trials suggest the presence of a quantifiable reduction in energy expenditure rate seen by the implementation of an autonomous active ankle exoskeleton in flat-terrain walking protocols. Additionally, the time to convergence, defined as the time a particular data-set takes to reach steady-state, was calculated using the same physiological responses. The results of this observation suggest that the time to convergence of metabolic indicators is much shorter than previously assumed. Finally, the potential benefits of utilizing a custom exoskeleton interface are quantified and elaborated.","abstract_html":"In this thesis, I designed and conducted an experiment that looks to confirm the metabolic cost decrease associated with the usage of an autonomous active ankle exoskeleton. The primary method to identify the associated metabolic costs was through the comparison of cardiovascular and respiratory activity during gait with and without the use of the exoskeleton. Rates of oxygen consumption, carbon dioxide production, and pulse were recorded for both control and experimental trials. Using these physiological responses, associated energy expenditure rates were calculated. The results of these trials suggest the presence of a quantifiable reduction in energy expenditure rate seen by the implementation of an autonomous active ankle exoskeleton in flat-terrain walking protocols. Additionally, the time to convergence, defined as the time a particular data-set takes to reach steady-state, was calculated using the same physiological responses. The results of this observation suggest that the time to convergence of metabolic indicators is much shorter than previously assumed. Finally, the potential benefits of utilizing a custom exoskeleton interface are quantified and elaborated.","abstract_has_math":false,"creators":["Koo, Bon Ho Brandon."],"institution":"Massachusetts Institute of Technology","degree_name":"Bachelor","degree_level":null,"degree_discipline":null,"degree_department":"MechE","school":null,"contributors":[],"advisors":["Hugh Herr."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-27T03:17:26Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1130578072"],"render_values":[{"text":"1130578072","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/123284","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/123284","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F123284","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F123284","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hugh Herr."]},{"key":"dc:contributor.department","label":"Department","values":["MechE"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Koo, Bon Ho Brandon."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-12-13T19:02:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-13T19:02:27Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Bachelor"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1130578072"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/123284"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0ad52256-d596-40f9-8d7c-e16d581a5032\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Autonomous active ankle exo-skeleton devices provide metabolic cost reduction</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <Authors> <Author> <DisplayName>Koo, Bon Ho Brandon.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>In this thesis, I designed and conducted an experiment that looks to confirm the metabolic cost decrease associated with the usage of an autonomous active ankle exoskeleton. The primary method to identify the associated metabolic costs was through the comparison of cardiovascular and respiratory activity during gait with and without the use of the exoskeleton. Rates of oxygen consumption, carbon dioxide production, and pulse were recorded for both control and experimental trials. Using these physiological responses, associated energy expenditure rates were calculated. The results of these trials suggest the presence of a quantifiable reduction in energy expenditure rate seen by the implementation of an autonomous active ankle exoskeleton in flat-terrain walking protocols. Additionally, the time to convergence, defined as the time a particular data-set takes to reach steady-state, was calculated using the same physiological responses. The results of this observation suggest that the time to convergence of metabolic indicators is much shorter than previously assumed. Finally, the potential benefits of utilizing a custom exoskeleton interface are quantified and elaborated.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2019","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 35-36)."]},{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, I designed and conducted an experiment that looks to confirm the metabolic cost decrease associated with the usage of an autonomous active ankle exoskeleton. The primary method to identify the associated metabolic costs was through the comparison of cardiovascular and respiratory activity during gait with and without the use of the exoskeleton. Rates of oxygen consumption, carbon dioxide production, and pulse were recorded for both control and experimental trials. Using these physiological responses, associated energy expenditure rates were calculated. The results of these trials suggest the presence of a quantifiable reduction in energy expenditure rate seen by the implementation of an autonomous active ankle exoskeleton in flat-terrain walking protocols. Additionally, the time to convergence, defined as the time a particular data-set takes to reach steady-state, was calculated using the same physiological responses. The results of this observation suggest that the time to convergence of metabolic indicators is much shorter than previously assumed. Finally, the potential benefits of utilizing a custom exoskeleton interface are quantified and elaborated."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.B. Massachusetts Institute of Technology, Department of Mechanical Engineering"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2019-12-13T19:02:26Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Bon Ho Brandon Koo."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["36 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Autonomous active ankle exo-skeleton devices provide metabolic cost reduction"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0ad52256-d596-40f9-8d7c-e16d581a5032\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Autonomous active ankle exo-skeleton devices provide metabolic cost reduction</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <Authors> <Author> <DisplayName>Koo, Bon Ho Brandon.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>In this thesis, I designed and conducted an experiment that looks to confirm the metabolic cost decrease associated with the usage of an autonomous active ankle exoskeleton. The primary method to identify the associated metabolic costs was through the comparison of cardiovascular and respiratory activity during gait with and without the use of the exoskeleton. Rates of oxygen consumption, carbon dioxide production, and pulse were recorded for both control and experimental trials. Using these physiological responses, associated energy expenditure rates were calculated. The results of these trials suggest the presence of a quantifiable reduction in energy expenditure rate seen by the implementation of an autonomous active ankle exoskeleton in flat-terrain walking protocols. Additionally, the time to convergence, defined as the time a particular data-set takes to reach steady-state, was calculated using the same physiological responses. The results of this observation suggest that the time to convergence of metabolic indicators is much shorter than previously assumed. Finally, the potential benefits of utilizing a custom exoskeleton interface are quantified and elaborated.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Hugh Herr."],"dc:contributor.department":["MechE"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Mechanical Engineering."],"dc:creator":["Koo, Bon Ho Brandon."],"dc:date.accessioned":["2019-12-13T19:02:27Z"],"dc:date.available":["2019-12-13T19:02:27Z"],"dc:date.copyright":["2019"],"dc:date.issued":["2019"],"dc:description":["Thesis: S.B., Massachusetts Institute of Technology, Department of Mechanical Engineering, 2019","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 35-36)."],"dc:description.abstract":["In this thesis, I designed and conducted an experiment that looks to confirm the metabolic cost decrease associated with the usage of an autonomous active ankle exoskeleton. The primary method to identify the associated metabolic costs was through the comparison of cardiovascular and respiratory activity during gait with and without the use of the exoskeleton. Rates of oxygen consumption, carbon dioxide production, and pulse were recorded for both control and experimental trials. Using these physiological responses, associated energy expenditure rates were calculated. The results of these trials suggest the presence of a quantifiable reduction in energy expenditure rate seen by the implementation of an autonomous active ankle exoskeleton in flat-terrain walking protocols. Additionally, the time to convergence, defined as the time a particular data-set takes to reach steady-state, was calculated using the same physiological responses. The results of this observation suggest that the time to convergence of metabolic indicators is much shorter than previously assumed. Finally, the potential benefits of utilizing a custom exoskeleton interface are quantified and elaborated."],"dc:description.collection":["S.B. Massachusetts Institute of Technology, Department of Mechanical Engineering"],"dc:description.degree":["S.B."],"dc:description.imported":["2019-12-13T19:02:26Z"],"dc:description.statementofresponsibility":["by Bon Ho Brandon Koo."],"dc:format.extent":["36 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1130578072"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/123284"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Autonomous active ankle exo-skeleton devices provide metabolic cost reduction"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Bachelor"]},"updated_at":"2026-11-27T03:17:26Z"}