{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/123361"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/123361","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Compact neutron sources for zero knowledge warhead verification via epithermal neutron transmission analysis","abstract":"In anarchic international environments, verification methods improve the viability of arms control agreements and disarmament measures by allowing party states to escape the security dilemma. However, warhead verification requires confident assurance of warhead authenticity while protecting design information about the interrogated object. Zeroknowledge physical cryptography provides a solution to the verification paradox by introducing system designs that do not require electronic information barriers and protect sensitive information during measurement. Compact epithermal neutron sources enable the verification process to occur on-site and minimize the security risk of transporting special nuclear material to dedicated verification facilities. Experimental results demonstrate the feasibility of a tomographic approach to zero-knowledge physical cryptography, and MC simulations offer promising results for compact epithermal neutron sources.","abstract_html":"In anarchic international environments, verification methods improve the viability of arms control agreements and disarmament measures by allowing party states to escape the security dilemma. However, warhead verification requires confident assurance of warhead authenticity while protecting design information about the interrogated object. Zeroknowledge physical cryptography provides a solution to the verification paradox by introducing system designs that do not require electronic information barriers and protect sensitive information during measurement. Compact epithermal neutron sources enable the verification process to occur on-site and minimize the security risk of transporting special nuclear material to dedicated verification facilities. Experimental results demonstrate the feasibility of a tomographic approach to zero-knowledge physical cryptography, and MC simulations offer promising results for compact epithermal neutron sources.","abstract_has_math":false,"creators":["Engel, Ezra Max."],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"NucEng","school":null,"contributors":[],"advisors":["Areg Danagoulian."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-27T07:24:40Z","subjects":["Nuclear Science and Engineering."],"languages":["en"],"rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1134768345"],"render_values":[{"text":"1134768345","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/123361","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/123361","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F123361","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F123361","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Areg Danagoulian."]},{"key":"dc:contributor.department","label":"Department","values":["NucEng"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Engel, Ezra Max."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-01-08T19:33:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-01-08T19:33:34Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1134768345"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/123361"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"412cccd0-57b3-4583-8658-6f1720b8fa33\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Compact neutron sources for zero knowledge warhead verification via epithermal neutron transmission analysis</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <Authors> <Author> <DisplayName>Engel, Ezra Max.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Nuclear Science and Engineering.</Keyword> <Abstract>In anarchic international environments, verification methods improve the viability of arms control agreements and disarmament measures by allowing party states to escape the security dilemma. However, warhead verification requires confident assurance of warhead authenticity while protecting design information about the interrogated object. Zeroknowledge physical cryptography provides a solution to the verification paradox by introducing system designs that do not require electronic information barriers and protect sensitive information during measurement. Compact epithermal neutron sources enable the verification process to occur on-site and minimize the security risk of transporting special nuclear material to dedicated verification facilities. Experimental results demonstrate the feasibility of a tomographic approach to zero-knowledge physical cryptography, and MC simulations offer promising results for compact epithermal neutron sources.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Thesis: S.M., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2019","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (pages 67-71)."]},{"key":"dc:description.abstract","label":"Abstract","values":["In anarchic international environments, verification methods improve the viability of arms control agreements and disarmament measures by allowing party states to escape the security dilemma. However, warhead verification requires confident assurance of warhead authenticity while protecting design information about the interrogated object. Zeroknowledge physical cryptography provides a solution to the verification paradox by introducing system designs that do not require electronic information barriers and protect sensitive information during measurement. Compact epithermal neutron sources enable the verification process to occur on-site and minimize the security risk of transporting special nuclear material to dedicated verification facilities. Experimental results demonstrate the feasibility of a tomographic approach to zero-knowledge physical cryptography, and MC simulations offer promising results for compact epithermal neutron sources."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.M. Massachusetts Institute of Technology, Department of Nuclear Science and Engineering"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2020-01-08T19:33:33Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Ezra Max Engel."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["71 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Compact neutron sources for zero knowledge warhead verification via epithermal neutron transmission analysis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"412cccd0-57b3-4583-8658-6f1720b8fa33\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Compact neutron sources for zero knowledge warhead verification via epithermal neutron transmission analysis</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <Authors> <Author> <DisplayName>Engel, Ezra Max.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Nuclear Science and Engineering.</Keyword> <Abstract>In anarchic international environments, verification methods improve the viability of arms control agreements and disarmament measures by allowing party states to escape the security dilemma. However, warhead verification requires confident assurance of warhead authenticity while protecting design information about the interrogated object. Zeroknowledge physical cryptography provides a solution to the verification paradox by introducing system designs that do not require electronic information barriers and protect sensitive information during measurement. Compact epithermal neutron sources enable the verification process to occur on-site and minimize the security risk of transporting special nuclear material to dedicated verification facilities. Experimental results demonstrate the feasibility of a tomographic approach to zero-knowledge physical cryptography, and MC simulations offer promising results for compact epithermal neutron sources.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Areg Danagoulian."],"dc:contributor.department":["NucEng"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Nuclear Science and Engineering."],"dc:creator":["Engel, Ezra Max."],"dc:date.accessioned":["2020-01-08T19:33:34Z"],"dc:date.available":["2020-01-08T19:33:34Z"],"dc:date.copyright":["2019"],"dc:date.issued":["2019"],"dc:description":["This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Thesis: S.M., Massachusetts Institute of Technology, Department of Nuclear Science and Engineering, 2019","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (pages 67-71)."],"dc:description.abstract":["In anarchic international environments, verification methods improve the viability of arms control agreements and disarmament measures by allowing party states to escape the security dilemma. However, warhead verification requires confident assurance of warhead authenticity while protecting design information about the interrogated object. Zeroknowledge physical cryptography provides a solution to the verification paradox by introducing system designs that do not require electronic information barriers and protect sensitive information during measurement. Compact epithermal neutron sources enable the verification process to occur on-site and minimize the security risk of transporting special nuclear material to dedicated verification facilities. Experimental results demonstrate the feasibility of a tomographic approach to zero-knowledge physical cryptography, and MC simulations offer promising results for compact epithermal neutron sources."],"dc:description.collection":["S.M. Massachusetts Institute of Technology, Department of Nuclear Science and Engineering"],"dc:description.degree":["S.M."],"dc:description.imported":["2020-01-08T19:33:33Z"],"dc:description.statementofresponsibility":["by Ezra Max Engel."],"dc:format.extent":["71 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1134768345"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/123361"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Science and Engineering."],"dc:title":["Compact neutron sources for zero knowledge warhead verification via epithermal neutron transmission analysis"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master"]},"updated_at":"2026-11-27T07:24:40Z"}