{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/124074"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/124074","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design of an advanced sEMG processor for wearable robotics applications","abstract":"This thesis presents the design and evaluation of a surface electromyography(sEMG) acquisition platform specialized for wearable robotic applications. While sEMG is one of the best ways to interpret human muscle and neural activity, the research field in wearable robotics has limitations in utilizing sEMG signals with commercially-available sEMG acquisition platforms. These limitations include a large and bulky electronics package, poor portability, insufficient electrode versatility, and limited reconfigurability. This thesis aims to present an effective design that provides solutions to these many difficulties while insuring robustness and acquisition signal quality. The thesis reasons and explains in detail every design decision and process among the system development and manufacturing. The evaluation of the manufactured system compared to a benchtop state-of-the-art sEMG recording platform is demonstrated. Practical utility of the developed sEMG measurement system is also demonstrated with a real world wearable robotic application.","abstract_html":"This thesis presents the design and evaluation of a surface electromyography(sEMG) acquisition platform specialized for wearable robotic applications. While sEMG is one of the best ways to interpret human muscle and neural activity, the research field in wearable robotics has limitations in utilizing sEMG signals with commercially-available sEMG acquisition platforms. These limitations include a large and bulky electronics package, poor portability, insufficient electrode versatility, and limited reconfigurability. This thesis aims to present an effective design that provides solutions to these many difficulties while insuring robustness and acquisition signal quality. The thesis reasons and explains in detail every design decision and process among the system development and manufacturing. The evaluation of the manufactured system compared to a benchtop state-of-the-art sEMG recording platform is demonstrated. Practical utility of the developed sEMG measurement system is also demonstrated with a real world wearable robotic application.","abstract_has_math":false,"creators":["Yeon, Seong Ho."],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"Media","school":null,"contributors":[],"advisors":["Hugh Herr."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019","date_published":"2019","updated_at":"2026-11-27T03:16:51Z","subjects":["Program in Media Arts and Sciences"],"languages":["en"],"rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1142188711"],"render_values":[{"text":"1142188711","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/124074","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/124074","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F124074","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F124074","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Hugh Herr."]},{"key":"dc:contributor.department","label":"Department","values":["Media"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Program in Media Arts and Sciences (Massachusetts Institute of Technology)"]},{"key":"dc:creator","label":"Author","values":["Yeon, Seong Ho."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-03-09T18:52:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-03-09T18:52:23Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019"]},{"key":"dc:date.issued","label":"Date","values":["2019"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Program in Media Arts and Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1142188711"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/124074"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"049d63d5-afd6-4ea6-952e-694754713ecc\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design of an advanced sEMG processor for wearable robotics applications</Title> <Subtitle>Design of an advanced surface electromyography processor for wearable robotics applications</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <Authors> <Author> <DisplayName>Yeon, Seong Ho.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Program in Media Arts and Sciences</Keyword> <Abstract>This thesis presents the design and evaluation of a surface electromyography(sEMG) acquisition platform specialized for wearable robotic applications. While sEMG is one of the best ways to interpret human muscle and neural activity, the research field in wearable robotics has limitations in utilizing sEMG signals with commercially-available sEMG acquisition platforms. These limitations include a large and bulky electronics package, poor portability, insufficient electrode versatility, and limited reconfigurability. This thesis aims to present an effective design that provides solutions to these many difficulties while insuring robustness and acquisition signal quality. The thesis reasons and explains in detail every design decision and process among the system development and manufacturing. The evaluation of the manufactured system compared to a benchtop state-of-the-art sEMG recording platform is demonstrated. Practical utility of the developed sEMG measurement system is also demonstrated with a real world wearable robotic application.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.M., Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2019","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 139-142)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the design and evaluation of a surface electromyography(sEMG) acquisition platform specialized for wearable robotic applications. While sEMG is one of the best ways to interpret human muscle and neural activity, the research field in wearable robotics has limitations in utilizing sEMG signals with commercially-available sEMG acquisition platforms. These limitations include a large and bulky electronics package, poor portability, insufficient electrode versatility, and limited reconfigurability. This thesis aims to present an effective design that provides solutions to these many difficulties while insuring robustness and acquisition signal quality. The thesis reasons and explains in detail every design decision and process among the system development and manufacturing. The evaluation of the manufactured system compared to a benchtop state-of-the-art sEMG recording platform is demonstrated. Practical utility of the developed sEMG measurement system is also demonstrated with a real world wearable robotic application."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.M. Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2020-03-09T18:52:22Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Seong Ho Yeon."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["142 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design of an advanced sEMG processor for wearable robotics applications"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Design of an advanced surface electromyography processor for wearable robotics applications"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"049d63d5-afd6-4ea6-952e-694754713ecc\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design of an advanced sEMG processor for wearable robotics applications</Title> <Subtitle>Design of an advanced surface electromyography processor for wearable robotics applications</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2019</PublicationDate> <Authors> <Author> <DisplayName>Yeon, Seong Ho.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Program in Media Arts and Sciences</Keyword> <Abstract>This thesis presents the design and evaluation of a surface electromyography(sEMG) acquisition platform specialized for wearable robotic applications. While sEMG is one of the best ways to interpret human muscle and neural activity, the research field in wearable robotics has limitations in utilizing sEMG signals with commercially-available sEMG acquisition platforms. These limitations include a large and bulky electronics package, poor portability, insufficient electrode versatility, and limited reconfigurability. This thesis aims to present an effective design that provides solutions to these many difficulties while insuring robustness and acquisition signal quality. The thesis reasons and explains in detail every design decision and process among the system development and manufacturing. The evaluation of the manufactured system compared to a benchtop state-of-the-art sEMG recording platform is demonstrated. Practical utility of the developed sEMG measurement system is also demonstrated with a real world wearable robotic application.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Hugh Herr."],"dc:contributor.department":["Media"],"dc:contributor.other":["Program in Media Arts and Sciences (Massachusetts Institute of Technology)"],"dc:creator":["Yeon, Seong Ho."],"dc:date.accessioned":["2020-03-09T18:52:23Z"],"dc:date.available":["2020-03-09T18:52:23Z"],"dc:date.copyright":["2019"],"dc:date.issued":["2019"],"dc:description":["Thesis: S.M., Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences, 2019","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 139-142)."],"dc:description.abstract":["This thesis presents the design and evaluation of a surface electromyography(sEMG) acquisition platform specialized for wearable robotic applications. While sEMG is one of the best ways to interpret human muscle and neural activity, the research field in wearable robotics has limitations in utilizing sEMG signals with commercially-available sEMG acquisition platforms. These limitations include a large and bulky electronics package, poor portability, insufficient electrode versatility, and limited reconfigurability. This thesis aims to present an effective design that provides solutions to these many difficulties while insuring robustness and acquisition signal quality. The thesis reasons and explains in detail every design decision and process among the system development and manufacturing. The evaluation of the manufactured system compared to a benchtop state-of-the-art sEMG recording platform is demonstrated. Practical utility of the developed sEMG measurement system is also demonstrated with a real world wearable robotic application."],"dc:description.collection":["S.M. Massachusetts Institute of Technology, School of Architecture and Planning, Program in Media Arts and Sciences"],"dc:description.degree":["S.M."],"dc:description.imported":["2020-03-09T18:52:22Z"],"dc:description.statementofresponsibility":["by Seong Ho Yeon."],"dc:format.extent":["142 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1142188711"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/124074"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Program in Media Arts and Sciences"],"dc:title":["Design of an advanced sEMG processor for wearable robotics applications"],"dc:title.alternative":["Design of an advanced surface electromyography processor for wearable robotics applications"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master"]},"updated_at":"2026-11-27T03:16:51Z"}