{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/127077"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/127077","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A root cause analysis of REXIS detection efficiency loss during phase E operations","abstract":"The Regolith X-ray Imaging Spectrometer (REXIS) is a student-built instrument flown on NASA's Origins, Spectral Interpretation, Resource Identification, Safety, Regolith Explorer (OSIRIS-REx) mission. During main science operations, the instrument experienced detector efficiency loss in the form of loss of iron calibration source counts, which greatly affected the science output. In this thesis, a root cause investigation is performed on the loss of iron counts, and an optical light leak onto the edge of the instrument's detectors is identified as the most likely cause. A CAST analysis is then performed to identify possible organizational and cultural causes of the design that allowed for an optical light leak, and recommendations for future similar instruments (low-cost, high-risk) are made.","abstract_html":"The Regolith X-ray Imaging Spectrometer (REXIS) is a student-built instrument flown on NASA&#x27;s Origins, Spectral Interpretation, Resource Identification, Safety, Regolith Explorer (OSIRIS-REx) mission. During main science operations, the instrument experienced detector efficiency loss in the form of loss of iron calibration source counts, which greatly affected the science output. In this thesis, a root cause investigation is performed on the loss of iron counts, and an optical light leak onto the edge of the instrument&#x27;s detectors is identified as the most likely cause. A CAST analysis is then performed to identify possible organizational and cultural causes of the design that allowed for an optical light leak, and recommendations for future similar instruments (low-cost, high-risk) are made.","abstract_has_math":false,"creators":["Lambert, Madeline(Madeline Marie)"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"Aero","school":null,"contributors":[],"advisors":["Rebecca Masterson."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-27T06:22:19Z","subjects":["Aeronautics and Astronautics."],"languages":["en"],"rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1191820963"],"render_values":[{"text":"1191820963","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/127077","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/127077","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F127077","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F127077","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rebecca Masterson."]},{"key":"dc:contributor.department","label":"Department","values":["Aero"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Aeronautics and Astronautics."]},{"key":"dc:creator","label":"Author","values":["Lambert, Madeline(Madeline Marie)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-03T17:45:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-03T17:45:46Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aeronautics and Astronautics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1191820963"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/127077"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2c976785-57d5-464c-8800-0edf2d66910b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>A root cause analysis of REXIS detection efficiency loss during phase E operations</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Lambert, Madeline(Madeline Marie)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Aeronautics and Astronautics.</Keyword> <Abstract>The Regolith X-ray Imaging Spectrometer (REXIS) is a student-built instrument flown on NASA's Origins, Spectral Interpretation, Resource Identification, Safety, Regolith Explorer (OSIRIS-REx) mission. During main science operations, the instrument experienced detector efficiency loss in the form of loss of iron calibration source counts, which greatly affected the science output. In this thesis, a root cause investigation is performed on the loss of iron counts, and an optical light leak onto the edge of the instrument's detectors is identified as the most likely cause. A CAST analysis is then performed to identify possible organizational and cultural causes of the design that allowed for an optical light leak, and recommendations for future similar instruments (low-cost, high-risk) are made.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, May, 2020","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 203-205)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The Regolith X-ray Imaging Spectrometer (REXIS) is a student-built instrument flown on NASA's Origins, Spectral Interpretation, Resource Identification, Safety, Regolith Explorer (OSIRIS-REx) mission. During main science operations, the instrument experienced detector efficiency loss in the form of loss of iron calibration source counts, which greatly affected the science output. In this thesis, a root cause investigation is performed on the loss of iron counts, and an optical light leak onto the edge of the instrument's detectors is identified as the most likely cause. A CAST analysis is then performed to identify possible organizational and cultural causes of the design that allowed for an optical light leak, and recommendations for future similar instruments (low-cost, high-risk) are made."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.M. Massachusetts Institute of Technology, Department of Aeronautics and Astronautics"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2020-09-03T17:45:46Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Madeline Lambert."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["205 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A root cause analysis of REXIS detection efficiency loss during phase E operations"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2c976785-57d5-464c-8800-0edf2d66910b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>A root cause analysis of REXIS detection efficiency loss during phase E operations</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Lambert, Madeline(Madeline Marie)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Aeronautics and Astronautics.</Keyword> <Abstract>The Regolith X-ray Imaging Spectrometer (REXIS) is a student-built instrument flown on NASA's Origins, Spectral Interpretation, Resource Identification, Safety, Regolith Explorer (OSIRIS-REx) mission. During main science operations, the instrument experienced detector efficiency loss in the form of loss of iron calibration source counts, which greatly affected the science output. In this thesis, a root cause investigation is performed on the loss of iron counts, and an optical light leak onto the edge of the instrument's detectors is identified as the most likely cause. A CAST analysis is then performed to identify possible organizational and cultural causes of the design that allowed for an optical light leak, and recommendations for future similar instruments (low-cost, high-risk) are made.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Rebecca Masterson."],"dc:contributor.department":["Aero"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Aeronautics and Astronautics."],"dc:creator":["Lambert, Madeline(Madeline Marie)"],"dc:date.accessioned":["2020-09-03T17:45:46Z"],"dc:date.available":["2020-09-03T17:45:46Z"],"dc:date.copyright":["2020"],"dc:date.issued":["2020"],"dc:description":["Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, May, 2020","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 203-205)."],"dc:description.abstract":["The Regolith X-ray Imaging Spectrometer (REXIS) is a student-built instrument flown on NASA's Origins, Spectral Interpretation, Resource Identification, Safety, Regolith Explorer (OSIRIS-REx) mission. During main science operations, the instrument experienced detector efficiency loss in the form of loss of iron calibration source counts, which greatly affected the science output. In this thesis, a root cause investigation is performed on the loss of iron counts, and an optical light leak onto the edge of the instrument's detectors is identified as the most likely cause. A CAST analysis is then performed to identify possible organizational and cultural causes of the design that allowed for an optical light leak, and recommendations for future similar instruments (low-cost, high-risk) are made."],"dc:description.collection":["S.M. Massachusetts Institute of Technology, Department of Aeronautics and Astronautics"],"dc:description.degree":["S.M."],"dc:description.imported":["2020-09-03T17:45:46Z"],"dc:description.statementofresponsibility":["by Madeline Lambert."],"dc:format.extent":["205 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1191820963"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/127077"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Aeronautics and Astronautics."],"dc:title":["A root cause analysis of REXIS detection efficiency loss during phase E operations"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master"]},"updated_at":"2026-11-27T06:22:19Z"}