{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/127081"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/127081","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Low noise magnetic fields in ultracold experiment","abstract":"Ultracold atomic and molecular experiments rely on low noise ambient magnetic fields for precision spectroscopy and studying Feshbach resonances with narrow linewidths, which can be on the order of 1 [mu] T. The ambient field is impacted by both the Earth's magnetic field and technical noise from surrounding electrical equipment, which can vary through the day. We built an apparatus using an Arduino microprocessor to record the ambient fields with magnetometers located outside the vacuum chamber containing the atoms and output transformed waveforms at 30 Hz intervals to be feed forwarded to the coils and cancel both the average field and fluctuations. We achieved an RMS of 37 nT along one axis in the magnetic fields in our test setup using this apparatus, reducing the 60 Hz component by 30 dB and the 180 Hz component by 20 dB.","abstract_html":"Ultracold atomic and molecular experiments rely on low noise ambient magnetic fields for precision spectroscopy and studying Feshbach resonances with narrow linewidths, which can be on the order of 1 [mu] T. The ambient field is impacted by both the Earth&#x27;s magnetic field and technical noise from surrounding electrical equipment, which can vary through the day. We built an apparatus using an Arduino microprocessor to record the ambient fields with magnetometers located outside the vacuum chamber containing the atoms and output transformed waveforms at 30 Hz intervals to be feed forwarded to the coils and cancel both the average field and fluctuations. We achieved an RMS of 37 nT along one axis in the magnetic fields in our test setup using this apparatus, reducing the 60 Hz component by 30 dB and the 180 Hz component by 20 dB.","abstract_has_math":false,"creators":["Nolasco-Martinez, Eber."],"institution":"Massachusetts Institute of Technology","degree_name":"Bachelor","degree_level":null,"degree_discipline":null,"degree_department":"Phys","school":null,"contributors":[],"advisors":["Wolfgang Ketterle."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-27T04:18:21Z","subjects":["Physics."],"languages":["en"],"rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1191824144"],"render_values":[{"text":"1191824144","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/127081","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/127081","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F127081","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F127081","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wolfgang Ketterle."]},{"key":"dc:contributor.department","label":"Department","values":["Phys"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Physics."]},{"key":"dc:creator","label":"Author","values":["Nolasco-Martinez, Eber."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-03T17:46:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-03T17:46:00Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Bachelor"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1191824144"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/127081"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0e758f0f-ab8e-4867-917d-34923619be9e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Low noise magnetic fields in ultracold experiment</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Nolasco-Martinez, Eber.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>Ultracold atomic and molecular experiments rely on low noise ambient magnetic fields for precision spectroscopy and studying Feshbach resonances with narrow linewidths, which can be on the order of 1 [mu] T. The ambient field is impacted by both the Earth's magnetic field and technical noise from surrounding electrical equipment, which can vary through the day. We built an apparatus using an Arduino microprocessor to record the ambient fields with magnetometers located outside the vacuum chamber containing the atoms and output transformed waveforms at 30 Hz intervals to be feed forwarded to the coils and cancel both the average field and fluctuations. We achieved an RMS of 37 nT along one axis in the magnetic fields in our test setup using this apparatus, reducing the 60 Hz component by 30 dB and the 180 Hz component by 20 dB.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.B., Massachusetts Institute of Technology, Department of Physics, 2020","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 54-55)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Ultracold atomic and molecular experiments rely on low noise ambient magnetic fields for precision spectroscopy and studying Feshbach resonances with narrow linewidths, which can be on the order of 1 [mu] T. The ambient field is impacted by both the Earth's magnetic field and technical noise from surrounding electrical equipment, which can vary through the day. We built an apparatus using an Arduino microprocessor to record the ambient fields with magnetometers located outside the vacuum chamber containing the atoms and output transformed waveforms at 30 Hz intervals to be feed forwarded to the coils and cancel both the average field and fluctuations. We achieved an RMS of 37 nT along one axis in the magnetic fields in our test setup using this apparatus, reducing the 60 Hz component by 30 dB and the 180 Hz component by 20 dB."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.B. Massachusetts Institute of Technology, Department of Physics"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2020-09-03T17:46:00Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Eber Nolasco-Martinez."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["61 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Low noise magnetic fields in ultracold experiment"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0e758f0f-ab8e-4867-917d-34923619be9e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Low noise magnetic fields in ultracold experiment</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Nolasco-Martinez, Eber.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>Ultracold atomic and molecular experiments rely on low noise ambient magnetic fields for precision spectroscopy and studying Feshbach resonances with narrow linewidths, which can be on the order of 1 [mu] T. The ambient field is impacted by both the Earth's magnetic field and technical noise from surrounding electrical equipment, which can vary through the day. We built an apparatus using an Arduino microprocessor to record the ambient fields with magnetometers located outside the vacuum chamber containing the atoms and output transformed waveforms at 30 Hz intervals to be feed forwarded to the coils and cancel both the average field and fluctuations. We achieved an RMS of 37 nT along one axis in the magnetic fields in our test setup using this apparatus, reducing the 60 Hz component by 30 dB and the 180 Hz component by 20 dB.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Wolfgang Ketterle."],"dc:contributor.department":["Phys"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Physics."],"dc:creator":["Nolasco-Martinez, Eber."],"dc:date.accessioned":["2020-09-03T17:46:00Z"],"dc:date.available":["2020-09-03T17:46:00Z"],"dc:date.copyright":["2020"],"dc:date.issued":["2020"],"dc:description":["Thesis: S.B., Massachusetts Institute of Technology, Department of Physics, 2020","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 54-55)."],"dc:description.abstract":["Ultracold atomic and molecular experiments rely on low noise ambient magnetic fields for precision spectroscopy and studying Feshbach resonances with narrow linewidths, which can be on the order of 1 [mu] T. The ambient field is impacted by both the Earth's magnetic field and technical noise from surrounding electrical equipment, which can vary through the day. We built an apparatus using an Arduino microprocessor to record the ambient fields with magnetometers located outside the vacuum chamber containing the atoms and output transformed waveforms at 30 Hz intervals to be feed forwarded to the coils and cancel both the average field and fluctuations. We achieved an RMS of 37 nT along one axis in the magnetic fields in our test setup using this apparatus, reducing the 60 Hz component by 30 dB and the 180 Hz component by 20 dB."],"dc:description.collection":["S.B. Massachusetts Institute of Technology, Department of Physics"],"dc:description.degree":["S.B."],"dc:description.imported":["2020-09-03T17:46:00Z"],"dc:description.statementofresponsibility":["by Eber Nolasco-Martinez."],"dc:format.extent":["61 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1191824144"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/127081"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Low noise magnetic fields in ultracold experiment"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Bachelor"]},"updated_at":"2026-11-27T04:18:21Z"}