{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/127111"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/127111","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Development of an automated microfluidic system for the loading and unloading of cryoprotectants from mammalian oocytes","abstract":"Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that's success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients.","abstract_html":"Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that&#x27;s success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients.","abstract_has_math":false,"creators":["Zonis, Raphael Matan."],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"MechE","school":null,"contributors":[],"advisors":["Linda Griffith and Scott Manalis."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-27T06:23:16Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1191836223"],"render_values":[{"text":"1191836223","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/127111","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/127111","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F127111","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F127111","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Linda Griffith and Scott Manalis."]},{"key":"dc:contributor.department","label":"Department","values":["MechE"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Zonis, Raphael Matan."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-09-03T17:47:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-09-03T17:47:24Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1191836223"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/127111"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"37fac834-f0ec-4ab9-a0dd-8f6b21a917a0\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Development of an automated microfluidic system for the loading and unloading of cryoprotectants from mammalian oocytes</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Zonis, Raphael Matan.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that's success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, May, 2020","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 98-112)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that's success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.M. Massachusetts Institute of Technology, Department of Mechanical Engineering"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2020-09-03T17:47:24Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Raphael Matan Zonis."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["112 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of an automated microfluidic system for the loading and unloading of cryoprotectants from mammalian oocytes"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"37fac834-f0ec-4ab9-a0dd-8f6b21a917a0\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Development of an automated microfluidic system for the loading and unloading of cryoprotectants from mammalian oocytes</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Zonis, Raphael Matan.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that's success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Linda Griffith and Scott Manalis."],"dc:contributor.department":["MechE"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Mechanical Engineering."],"dc:creator":["Zonis, Raphael Matan."],"dc:date.accessioned":["2020-09-03T17:47:24Z"],"dc:date.available":["2020-09-03T17:47:24Z"],"dc:date.copyright":["2020"],"dc:date.issued":["2020"],"dc:description":["Thesis: S.M., Massachusetts Institute of Technology, Department of Mechanical Engineering, May, 2020","Cataloged from the official PDF of thesis.","Includes bibliographical references (pages 98-112)."],"dc:description.abstract":["Oocyte cryopreservation is an assistive reproductive procedure that has allowed women to overcome infertility and enjoy increased reproductive freedom. Despite a rapid increase in oocyte cryopreservation cycles over the past seven years, success rates both between and within clinics remain highly heterogeneous, negatively impacting clinical outcomes. This is because the clinical gold standard in oocyte cryopreservation, manual vitrification, is a technically challenging procedure that's success is strongly dependent on the experience, training, and attentiveness of the operator. In this thesis, the development of an automated platform for the introduction and removal of cryoprotective agents (CPAs) to and from the oocyte is described. By combining microfluidics, automation, and optical measurement systems, the proposed system aims to overcome the challenges inherent to manual vitrification, and improve upon other existing platforms designed to perform these tasks. Development and fabrication of the microfluidic component of this proposed system is described, and is validated through a proof-of-concept experiment. This work marks the first step towards a completely automated vitrification platform, capable of removing the uncertainty in success currently plaguing clinics and their patients."],"dc:description.collection":["S.M. Massachusetts Institute of Technology, Department of Mechanical Engineering"],"dc:description.degree":["S.M."],"dc:description.imported":["2020-09-03T17:47:24Z"],"dc:description.statementofresponsibility":["by Raphael Matan Zonis."],"dc:format.extent":["112 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1191836223"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/127111"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Development of an automated microfluidic system for the loading and unloading of cryoprotectants from mammalian oocytes"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master"]},"updated_at":"2026-11-27T06:23:16Z"}