{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/128588"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/128588","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Chip-Scale quantum magnetometry via CMOS integration with diamond color centers","abstract":"There has been increasing interest in spin-based quantum systems for a wide range of applications. In particular, the nitrogen-vacancy (NV) center in diamond has demonstrated outstanding sensing and imaging capabilities. However, previous control apparatuses of these quantum systems have used discrete instrumentation to both manipulate and detect the NV's spin state. This limits potential applications. In this thesis the first chip-scale Complementary Metal Oxide Semiconductor (CMOS) platform that integrates the necessary components for NV quantum state preparation, control, and measurement is presented. A CMOS integrated system capable of the control and readout of an ensemble of NV centers in diamond for magnetic field sensing is demonstrated. Scalar magnetic field sensing with a layer of nanodiamond particles achieving 74 [mu]T/[square root]Hz sensitivity is presented. In addition, vector magnetic field sensing with a slab of single crystalline diamond with enhanced sensitivity of 32.1 [mu]T/[square root]Hz is also presented. Techniques for strong generation and efficient delivery of microwave for quantum-state control, and optical filtering/detection of spin-dependent fluorescence for quantum-state readout are introduced. This hybrid architecture is a significant step towards a highly integrated quantum system with applications in life sciences, tracking, and advanced metrology.","abstract_html":"There has been increasing interest in spin-based quantum systems for a wide range of applications. In particular, the nitrogen-vacancy (NV) center in diamond has demonstrated outstanding sensing and imaging capabilities. However, previous control apparatuses of these quantum systems have used discrete instrumentation to both manipulate and detect the NV&#x27;s spin state. This limits potential applications. In this thesis the first chip-scale Complementary Metal Oxide Semiconductor (CMOS) platform that integrates the necessary components for NV quantum state preparation, control, and measurement is presented. A CMOS integrated system capable of the control and readout of an ensemble of NV centers in diamond for magnetic field sensing is demonstrated. Scalar magnetic field sensing with a layer of nanodiamond particles achieving 74 [mu]T/[square root]Hz sensitivity is presented. In addition, vector magnetic field sensing with a slab of single crystalline diamond with enhanced sensitivity of 32.1 [mu]T/[square root]Hz is also presented. Techniques for strong generation and efficient delivery of microwave for quantum-state control, and optical filtering/detection of spin-dependent fluorescence for quantum-state readout are introduced. This hybrid architecture is a significant step towards a highly integrated quantum system with applications in life sciences, tracking, and advanced metrology.","abstract_has_math":false,"creators":["Ibrahim, Mohamed Ibrahim Mohamed."],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"EECS","school":null,"contributors":[],"advisors":["Ruonan Han."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-27T05:20:46Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1220830877"],"render_values":[{"text":"1220830877","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/128588","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/128588","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F128588","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F128588","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ruonan Han."]},{"key":"dc:contributor.department","label":"Department","values":["EECS"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Ibrahim, Mohamed Ibrahim Mohamed."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-11-23T17:40:15Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-11-23T17:40:15Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1220830877"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/128588"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"225cea78-d889-45a7-a53d-cd614be305ac\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Chip-Scale quantum magnetometry via CMOS integration with diamond color centers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Ibrahim, Mohamed Ibrahim Mohamed.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>There has been increasing interest in spin-based quantum systems for a wide range of applications. In particular, the nitrogen-vacancy (NV) center in diamond has demonstrated outstanding sensing and imaging capabilities. However, previous control apparatuses of these quantum systems have used discrete instrumentation to both manipulate and detect the NV's spin state. This limits potential applications. In this thesis the first chip-scale Complementary Metal Oxide Semiconductor (CMOS) platform that integrates the necessary components for NV quantum state preparation, control, and measurement is presented. A CMOS integrated system capable of the control and readout of an ensemble of NV centers in diamond for magnetic field sensing is demonstrated. Scalar magnetic field sensing with a layer of nanodiamond particles achieving 74 [mu]T/[square root]Hz sensitivity is presented. In addition, vector magnetic field sensing with a slab of single crystalline diamond with enhanced sensitivity of 32.1 [mu]T/[square root]Hz is also presented. Techniques for strong generation and efficient delivery of microwave for quantum-state control, and optical filtering/detection of spin-dependent fluorescence for quantum-state readout are introduced. This hybrid architecture is a significant step towards a highly integrated quantum system with applications in life sciences, tracking, and advanced metrology.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, February, 2020","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 53-56)."]},{"key":"dc:description.abstract","label":"Abstract","values":["There has been increasing interest in spin-based quantum systems for a wide range of applications. In particular, the nitrogen-vacancy (NV) center in diamond has demonstrated outstanding sensing and imaging capabilities. However, previous control apparatuses of these quantum systems have used discrete instrumentation to both manipulate and detect the NV's spin state. This limits potential applications. In this thesis the first chip-scale Complementary Metal Oxide Semiconductor (CMOS) platform that integrates the necessary components for NV quantum state preparation, control, and measurement is presented. A CMOS integrated system capable of the control and readout of an ensemble of NV centers in diamond for magnetic field sensing is demonstrated. Scalar magnetic field sensing with a layer of nanodiamond particles achieving 74 [mu]T/[square root]Hz sensitivity is presented. In addition, vector magnetic field sensing with a slab of single crystalline diamond with enhanced sensitivity of 32.1 [mu]T/[square root]Hz is also presented. Techniques for strong generation and efficient delivery of microwave for quantum-state control, and optical filtering/detection of spin-dependent fluorescence for quantum-state readout are introduced. This hybrid architecture is a significant step towards a highly integrated quantum system with applications in life sciences, tracking, and advanced metrology."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.M. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2020-11-23T17:40:14Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Mohamed Ibrahim Mohamed Ibrahim."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["56 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Chip-Scale quantum magnetometry via CMOS integration with diamond color centers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"225cea78-d889-45a7-a53d-cd614be305ac\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Chip-Scale quantum magnetometry via CMOS integration with diamond color centers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Ibrahim, Mohamed Ibrahim Mohamed.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>There has been increasing interest in spin-based quantum systems for a wide range of applications. In particular, the nitrogen-vacancy (NV) center in diamond has demonstrated outstanding sensing and imaging capabilities. However, previous control apparatuses of these quantum systems have used discrete instrumentation to both manipulate and detect the NV's spin state. This limits potential applications. In this thesis the first chip-scale Complementary Metal Oxide Semiconductor (CMOS) platform that integrates the necessary components for NV quantum state preparation, control, and measurement is presented. A CMOS integrated system capable of the control and readout of an ensemble of NV centers in diamond for magnetic field sensing is demonstrated. Scalar magnetic field sensing with a layer of nanodiamond particles achieving 74 [mu]T/[square root]Hz sensitivity is presented. In addition, vector magnetic field sensing with a slab of single crystalline diamond with enhanced sensitivity of 32.1 [mu]T/[square root]Hz is also presented. Techniques for strong generation and efficient delivery of microwave for quantum-state control, and optical filtering/detection of spin-dependent fluorescence for quantum-state readout are introduced. This hybrid architecture is a significant step towards a highly integrated quantum system with applications in life sciences, tracking, and advanced metrology.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Ruonan Han."],"dc:contributor.department":["EECS"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Ibrahim, Mohamed Ibrahim Mohamed."],"dc:date.accessioned":["2020-11-23T17:40:15Z"],"dc:date.available":["2020-11-23T17:40:15Z"],"dc:date.copyright":["2020"],"dc:date.issued":["2020"],"dc:description":["Thesis: S.M., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, February, 2020","Cataloged from PDF version of thesis.","Includes bibliographical references (pages 53-56)."],"dc:description.abstract":["There has been increasing interest in spin-based quantum systems for a wide range of applications. In particular, the nitrogen-vacancy (NV) center in diamond has demonstrated outstanding sensing and imaging capabilities. However, previous control apparatuses of these quantum systems have used discrete instrumentation to both manipulate and detect the NV's spin state. This limits potential applications. In this thesis the first chip-scale Complementary Metal Oxide Semiconductor (CMOS) platform that integrates the necessary components for NV quantum state preparation, control, and measurement is presented. A CMOS integrated system capable of the control and readout of an ensemble of NV centers in diamond for magnetic field sensing is demonstrated. Scalar magnetic field sensing with a layer of nanodiamond particles achieving 74 [mu]T/[square root]Hz sensitivity is presented. In addition, vector magnetic field sensing with a slab of single crystalline diamond with enhanced sensitivity of 32.1 [mu]T/[square root]Hz is also presented. Techniques for strong generation and efficient delivery of microwave for quantum-state control, and optical filtering/detection of spin-dependent fluorescence for quantum-state readout are introduced. This hybrid architecture is a significant step towards a highly integrated quantum system with applications in life sciences, tracking, and advanced metrology."],"dc:description.collection":["S.M. Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science"],"dc:description.degree":["S.M."],"dc:description.imported":["2020-11-23T17:40:14Z"],"dc:description.statementofresponsibility":["by Mohamed Ibrahim Mohamed Ibrahim."],"dc:format.extent":["56 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1220830877"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/128588"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Chip-Scale quantum magnetometry via CMOS integration with diamond color centers"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master"]},"updated_at":"2026-11-27T05:20:46Z"}