{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/129137"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/129137","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Quantification of compensatory torso motion in post-stroke patients using wearable inertial measurement units","abstract":"Occupational Therapy (OT) tasks performed in home or remote environments cannot be observed or assessed by a clinician. For such environments, wearable sensor technologies could provide quantitative assessment of movement strategies to support clinical evaluation via telemedicine. This work presents an algorithm for estimating torso orientation and metrics of compensatory torso motion for upper extremity OT tasks using an Inertial Measurement Unit (IMU) worn on the sternum. Two post-stroke male participants with hemiparesis and two healthy age-matched male participants were evaluated while completing a series of OT evaluations and tasks, including assessments of active range of motion, pinch strength, standing balance, the Moberg pick-up test, Nine-hole peg test, and a custom peg board grasp task.","abstract_html":"Occupational Therapy (OT) tasks performed in home or remote environments cannot be observed or assessed by a clinician. For such environments, wearable sensor technologies could provide quantitative assessment of movement strategies to support clinical evaluation via telemedicine. This work presents an algorithm for estimating torso orientation and metrics of compensatory torso motion for upper extremity OT tasks using an Inertial Measurement Unit (IMU) worn on the sternum. Two post-stroke male participants with hemiparesis and two healthy age-matched male participants were evaluated while completing a series of OT evaluations and tasks, including assessments of active range of motion, pinch strength, standing balance, the Moberg pick-up test, Nine-hole peg test, and a custom peg board grasp task.","abstract_has_math":false,"creators":["Nguyen, Golda(Golda Minh Ý.)"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":"Aero","school":null,"contributors":[],"advisors":["Leia Stirling."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-27T23:31:10Z","subjects":["Aeronautics and Astronautics."],"languages":["en"],"rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1227503908"],"render_values":[{"text":"1227503908","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/129137","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/129137","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F129137","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F129137","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Leia Stirling."]},{"key":"dc:contributor.department","label":"Department","values":["Aero"]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Aeronautics and Astronautics."]},{"key":"dc:creator","label":"Author","values":["Nguyen, Golda(Golda Minh Ý.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2021-01-06T18:30:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2021-01-06T18:30:55Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aeronautics and Astronautics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["1227503908"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/129137"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4f22f268-f39e-4af1-a7fe-f685a8a4d4d8\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Quantification of compensatory torso motion in post-stroke patients using wearable inertial measurement units</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Nguyen, Golda(Golda Minh Ý.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Aeronautics and Astronautics.</Keyword> <Abstract>Occupational Therapy (OT) tasks performed in home or remote environments cannot be observed or assessed by a clinician. For such environments, wearable sensor technologies could provide quantitative assessment of movement strategies to support clinical evaluation via telemedicine. This work presents an algorithm for estimating torso orientation and metrics of compensatory torso motion for upper extremity OT tasks using an Inertial Measurement Unit (IMU) worn on the sternum. Two post-stroke male participants with hemiparesis and two healthy age-matched male participants were evaluated while completing a series of OT evaluations and tasks, including assessments of active range of motion, pinch strength, standing balance, the Moberg pick-up test, Nine-hole peg test, and a custom peg board grasp task.</Abstract> <Abstract>Torso orientation was estimated by decomposing sternum IMU orientation into angles (pitch, roll, yaw) in each anatomical plane (sagittal, coronal, transverse) and referenced against a standing balance posture. Orientation was measured as the participants completed tasks with their unaffected and affected sides (for stroke participants) or dominant and non-dominant sides (for healthy participants). Estimations of sternum IMU orientation were also compared against estimations from a Vicon optical motion capture system, and differences in estimations were not found to be operationally significant. IMU sensitivity to sensor to torso alignment was also evaluated and demonstrated the interaction between pitch and roll estimation. A threshold of nominal torso motion for each participant was created from the variance in torso orientation for tasks where the participant used their dominant or unaffected arm.</Abstract> <Abstract>A metric of percentage of time out of the range of natural variation was defined to assess operationally relevant differences that could inform clinical decision making. These case studies support the use of wearable IMUs to quantitatively assess compensatory torso motions and convey operationally relevant information about movement strategy to a clinician without the use of visual observation.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, September, 2020","Cataloged from student-submitted PDF of thesis.","Includes bibliographical references (pages 101-105)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Occupational Therapy (OT) tasks performed in home or remote environments cannot be observed or assessed by a clinician. For such environments, wearable sensor technologies could provide quantitative assessment of movement strategies to support clinical evaluation via telemedicine. This work presents an algorithm for estimating torso orientation and metrics of compensatory torso motion for upper extremity OT tasks using an Inertial Measurement Unit (IMU) worn on the sternum. Two post-stroke male participants with hemiparesis and two healthy age-matched male participants were evaluated while completing a series of OT evaluations and tasks, including assessments of active range of motion, pinch strength, standing balance, the Moberg pick-up test, Nine-hole peg test, and a custom peg board grasp task.","Torso orientation was estimated by decomposing sternum IMU orientation into angles (pitch, roll, yaw) in each anatomical plane (sagittal, coronal, transverse) and referenced against a standing balance posture. Orientation was measured as the participants completed tasks with their unaffected and affected sides (for stroke participants) or dominant and non-dominant sides (for healthy participants). Estimations of sternum IMU orientation were also compared against estimations from a Vicon optical motion capture system, and differences in estimations were not found to be operationally significant. IMU sensitivity to sensor to torso alignment was also evaluated and demonstrated the interaction between pitch and roll estimation. A threshold of nominal torso motion for each participant was created from the variance in torso orientation for tasks where the participant used their dominant or unaffected arm.","A metric of percentage of time out of the range of natural variation was defined to assess operationally relevant differences that could inform clinical decision making. These case studies support the use of wearable IMUs to quantitatively assess compensatory torso motions and convey operationally relevant information about movement strategy to a clinician without the use of visual observation."]},{"key":"dc:description.collection","label":"Dc Description Collection","values":["S.M. Massachusetts Institute of Technology, Department of Aeronautics and Astronautics"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.imported","label":"Dc Description Imported","values":["2021-01-06T18:30:54Z"]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Golda Nguyen."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["105 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Quantification of compensatory torso motion in post-stroke patients using wearable inertial measurement units"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4f22f268-f39e-4af1-a7fe-f685a8a4d4d8\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Quantification of compensatory torso motion in post-stroke patients using wearable inertial measurement units</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2020</PublicationDate> <Authors> <Author> <DisplayName>Nguyen, Golda(Golda Minh Ý.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Aeronautics and Astronautics.</Keyword> <Abstract>Occupational Therapy (OT) tasks performed in home or remote environments cannot be observed or assessed by a clinician. For such environments, wearable sensor technologies could provide quantitative assessment of movement strategies to support clinical evaluation via telemedicine. This work presents an algorithm for estimating torso orientation and metrics of compensatory torso motion for upper extremity OT tasks using an Inertial Measurement Unit (IMU) worn on the sternum. Two post-stroke male participants with hemiparesis and two healthy age-matched male participants were evaluated while completing a series of OT evaluations and tasks, including assessments of active range of motion, pinch strength, standing balance, the Moberg pick-up test, Nine-hole peg test, and a custom peg board grasp task.</Abstract> <Abstract>Torso orientation was estimated by decomposing sternum IMU orientation into angles (pitch, roll, yaw) in each anatomical plane (sagittal, coronal, transverse) and referenced against a standing balance posture. Orientation was measured as the participants completed tasks with their unaffected and affected sides (for stroke participants) or dominant and non-dominant sides (for healthy participants). Estimations of sternum IMU orientation were also compared against estimations from a Vicon optical motion capture system, and differences in estimations were not found to be operationally significant. IMU sensitivity to sensor to torso alignment was also evaluated and demonstrated the interaction between pitch and roll estimation. A threshold of nominal torso motion for each participant was created from the variance in torso orientation for tasks where the participant used their dominant or unaffected arm.</Abstract> <Abstract>A metric of percentage of time out of the range of natural variation was defined to assess operationally relevant differences that could inform clinical decision making. These case studies support the use of wearable IMUs to quantitatively assess compensatory torso motions and convey operationally relevant information about movement strategy to a clinician without the use of visual observation.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Leia Stirling."],"dc:contributor.department":["Aero"],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Aeronautics and Astronautics."],"dc:creator":["Nguyen, Golda(Golda Minh Ý.)"],"dc:date.accessioned":["2021-01-06T18:30:55Z"],"dc:date.available":["2021-01-06T18:30:55Z"],"dc:date.copyright":["2020"],"dc:date.issued":["2020"],"dc:description":["Thesis: S.M., Massachusetts Institute of Technology, Department of Aeronautics and Astronautics, September, 2020","Cataloged from student-submitted PDF of thesis.","Includes bibliographical references (pages 101-105)."],"dc:description.abstract":["Occupational Therapy (OT) tasks performed in home or remote environments cannot be observed or assessed by a clinician. For such environments, wearable sensor technologies could provide quantitative assessment of movement strategies to support clinical evaluation via telemedicine. This work presents an algorithm for estimating torso orientation and metrics of compensatory torso motion for upper extremity OT tasks using an Inertial Measurement Unit (IMU) worn on the sternum. Two post-stroke male participants with hemiparesis and two healthy age-matched male participants were evaluated while completing a series of OT evaluations and tasks, including assessments of active range of motion, pinch strength, standing balance, the Moberg pick-up test, Nine-hole peg test, and a custom peg board grasp task.","Torso orientation was estimated by decomposing sternum IMU orientation into angles (pitch, roll, yaw) in each anatomical plane (sagittal, coronal, transverse) and referenced against a standing balance posture. Orientation was measured as the participants completed tasks with their unaffected and affected sides (for stroke participants) or dominant and non-dominant sides (for healthy participants). Estimations of sternum IMU orientation were also compared against estimations from a Vicon optical motion capture system, and differences in estimations were not found to be operationally significant. IMU sensitivity to sensor to torso alignment was also evaluated and demonstrated the interaction between pitch and roll estimation. A threshold of nominal torso motion for each participant was created from the variance in torso orientation for tasks where the participant used their dominant or unaffected arm.","A metric of percentage of time out of the range of natural variation was defined to assess operationally relevant differences that could inform clinical decision making. These case studies support the use of wearable IMUs to quantitatively assess compensatory torso motions and convey operationally relevant information about movement strategy to a clinician without the use of visual observation."],"dc:description.collection":["S.M. Massachusetts Institute of Technology, Department of Aeronautics and Astronautics"],"dc:description.degree":["S.M."],"dc:description.imported":["2021-01-06T18:30:54Z"],"dc:description.statementofresponsibility":["by Golda Nguyen."],"dc:format.extent":["105 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["1227503908"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/129137"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Aeronautics and Astronautics."],"dc:title":["Quantification of compensatory torso motion in post-stroke patients using wearable inertial measurement units"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master"]},"updated_at":"2026-11-27T23:31:10Z"}