{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/147506"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/147506","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Interferometric, acousto-optic modulated diffuse correlation spectroscopy @ 1064 nm (AOM-iDCS) toward higher sensitivity, non-invasive measurement of cerebral blood flow","abstract":"Continuous, bedside monitoring of cerebral blood flow in patients at risk for neurovascular complications has the potential to decrease morbidity and mortality. While measures of systemic physiology can be used to infer cerebral perfusion, a technology that directly and continuously measures cerebral blood flow (CBF) is needed to properly manage treatment. Diffuse Correlation Spectroscopy (DCS) is an established optical technique that enables continuous, non-invasive, and direct measurements of CBF. The effectiveness of DCS in measuring CBF is hampered in adults by extracerebral contamination and limited depth sensitivity. The goal of this dissertation is to extend the usefulness of DCS in the adult population through the development of new techniques, including the use of longer wavelengths (1064 nm), acousto-optic modulation, and heterodyne detection to enhance CBF sensitivity and reduce extracerebral contamination. In each domain of improvement, we develop theory to describe the detected optical signals, advance hardware to enable measurements, and characterize the performance of the developed systems in phantom and human subject experiments. Each different improvement - wavelength extension, ultrasound sonification, heterodyne detection, and time-resolved detection - has its own advantage in terms of depth sensitivity, signal-to-noise ratio, and hardware/software complexity. As such, the techniques have the potential to be mixed and matched to increase sensitivity to CBF and dramatically improve the SNR of the measurement to enable non-invasive, bedside measurements.","abstract_html":"Continuous, bedside monitoring of cerebral blood flow in patients at risk for neurovascular complications has the potential to decrease morbidity and mortality. While measures of systemic physiology can be used to infer cerebral perfusion, a technology that directly and continuously measures cerebral blood flow (CBF) is needed to properly manage treatment. Diffuse Correlation Spectroscopy (DCS) is an established optical technique that enables continuous, non-invasive, and direct measurements of CBF. The effectiveness of DCS in measuring CBF is hampered in adults by extracerebral contamination and limited depth sensitivity. The goal of this dissertation is to extend the usefulness of DCS in the adult population through the development of new techniques, including the use of longer wavelengths (1064 nm), acousto-optic modulation, and heterodyne detection to enhance CBF sensitivity and reduce extracerebral contamination. In each domain of improvement, we develop theory to describe the detected optical signals, advance hardware to enable measurements, and characterize the performance of the developed systems in phantom and human subject experiments. Each different improvement - wavelength extension, ultrasound sonification, heterodyne detection, and time-resolved detection - has its own advantage in terms of depth sensitivity, signal-to-noise ratio, and hardware/software complexity. As such, the techniques have the potential to be mixed and matched to increase sensitivity to CBF and dramatically improve the SNR of the measurement to enable non-invasive, bedside measurements.","abstract_has_math":false,"creators":["Robinson, Mitchell Burrows"],"institution":"Massachusetts Institute of Technology","degree_name":"Doctoral","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Franceschini, Maria Angela"],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-09","date_published":"2022-09","updated_at":"2026-11-27T23:27:43Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["https://orcid.org/0000-0001-5810-0459"],"render_values":[{"text":"0000-0001-5810-0459","href":"https://orcid.org/0000-0001-5810-0459","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/147506","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/147506","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F147506","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F147506","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Franceschini, Maria Angela"]},{"key":"dc:creator","label":"Author","values":["Robinson, Mitchell Burrows"]},{"key":"dc:identifier.orcid","label":"ORCID","values":["https://orcid.org/0000-0001-5810-0459"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-01-19T19:54:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-01-19T19:54:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2022-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2022-09-16T18:25:46.873Z"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctoral","Doctor of Philosophy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/147506"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4bc56bbf-0b35-44de-92ad-2725b12aada5\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Interferometric, acousto-optic modulated diffuse correlation spectroscopy @ 1064 nm (AOM-iDCS) toward higher sensitivity, non-invasive measurement of cerebral blood flow</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-09</PublicationDate> <Authors> <Author> <DisplayName>Robinson, Mitchell Burrows</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Continuous, bedside monitoring of cerebral blood flow in patients at risk for neurovascular complications has the potential to decrease morbidity and mortality. While measures of systemic physiology can be used to infer cerebral perfusion, a technology that directly and continuously measures cerebral blood flow (CBF) is needed to properly manage treatment. Diffuse Correlation Spectroscopy (DCS) is an established optical technique that enables continuous, non-invasive, and direct measurements of CBF. The effectiveness of DCS in measuring CBF is hampered in adults by extracerebral contamination and limited depth sensitivity. The goal of this dissertation is to extend the usefulness of DCS in the adult population through the development of new techniques, including the use of longer wavelengths (1064 nm), acousto-optic modulation, and heterodyne detection to enhance CBF sensitivity and reduce extracerebral contamination. In each domain of improvement, we develop theory to describe the detected optical signals, advance hardware to enable measurements, and characterize the performance of the developed systems in phantom and human subject experiments. Each different improvement - wavelength extension, ultrasound sonification, heterodyne detection, and time-resolved detection - has its own advantage in terms of depth sensitivity, signal-to-noise ratio, and hardware/software complexity. As such, the techniques have the potential to be mixed and matched to increase sensitivity to CBF and dramatically improve the SNR of the measurement to enable non-invasive, bedside measurements.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description.abstract","label":"Abstract","values":["Continuous, bedside monitoring of cerebral blood flow in patients at risk for neurovascular complications has the potential to decrease morbidity and mortality. While measures of systemic physiology can be used to infer cerebral perfusion, a technology that directly and continuously measures cerebral blood flow (CBF) is needed to properly manage treatment. Diffuse Correlation Spectroscopy (DCS) is an established optical technique that enables continuous, non-invasive, and direct measurements of CBF. The effectiveness of DCS in measuring CBF is hampered in adults by extracerebral contamination and limited depth sensitivity. The goal of this dissertation is to extend the usefulness of DCS in the adult population through the development of new techniques, including the use of longer wavelengths (1064 nm), acousto-optic modulation, and heterodyne detection to enhance CBF sensitivity and reduce extracerebral contamination. In each domain of improvement, we develop theory to describe the detected optical signals, advance hardware to enable measurements, and characterize the performance of the developed systems in phantom and human subject experiments. Each different improvement - wavelength extension, ultrasound sonification, heterodyne detection, and time-resolved detection - has its own advantage in terms of depth sensitivity, signal-to-noise ratio, and hardware/software complexity. As such, the techniques have the potential to be mixed and matched to increase sensitivity to CBF and dramatically improve the SNR of the measurement to enable non-invasive, bedside measurements."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Interferometric, acousto-optic modulated diffuse correlation spectroscopy @ 1064 nm (AOM-iDCS) toward higher sensitivity, non-invasive measurement of cerebral blood flow"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4bc56bbf-0b35-44de-92ad-2725b12aada5\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Interferometric, acousto-optic modulated diffuse correlation spectroscopy @ 1064 nm (AOM-iDCS) toward higher sensitivity, non-invasive measurement of cerebral blood flow</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2022-09</PublicationDate> <Authors> <Author> <DisplayName>Robinson, Mitchell Burrows</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Continuous, bedside monitoring of cerebral blood flow in patients at risk for neurovascular complications has the potential to decrease morbidity and mortality. While measures of systemic physiology can be used to infer cerebral perfusion, a technology that directly and continuously measures cerebral blood flow (CBF) is needed to properly manage treatment. Diffuse Correlation Spectroscopy (DCS) is an established optical technique that enables continuous, non-invasive, and direct measurements of CBF. The effectiveness of DCS in measuring CBF is hampered in adults by extracerebral contamination and limited depth sensitivity. The goal of this dissertation is to extend the usefulness of DCS in the adult population through the development of new techniques, including the use of longer wavelengths (1064 nm), acousto-optic modulation, and heterodyne detection to enhance CBF sensitivity and reduce extracerebral contamination. In each domain of improvement, we develop theory to describe the detected optical signals, advance hardware to enable measurements, and characterize the performance of the developed systems in phantom and human subject experiments. Each different improvement - wavelength extension, ultrasound sonification, heterodyne detection, and time-resolved detection - has its own advantage in terms of depth sensitivity, signal-to-noise ratio, and hardware/software complexity. As such, the techniques have the potential to be mixed and matched to increase sensitivity to CBF and dramatically improve the SNR of the measurement to enable non-invasive, bedside measurements.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Franceschini, Maria Angela"],"dc:creator":["Robinson, Mitchell Burrows"],"dc:date.accessioned":["2023-01-19T19:54:52Z"],"dc:date.available":["2023-01-19T19:54:52Z"],"dc:date.issued":["2022-09"],"dc:date.submitted":["2022-09-16T18:25:46.873Z"],"dc:description.abstract":["Continuous, bedside monitoring of cerebral blood flow in patients at risk for neurovascular complications has the potential to decrease morbidity and mortality. While measures of systemic physiology can be used to infer cerebral perfusion, a technology that directly and continuously measures cerebral blood flow (CBF) is needed to properly manage treatment. Diffuse Correlation Spectroscopy (DCS) is an established optical technique that enables continuous, non-invasive, and direct measurements of CBF. The effectiveness of DCS in measuring CBF is hampered in adults by extracerebral contamination and limited depth sensitivity. The goal of this dissertation is to extend the usefulness of DCS in the adult population through the development of new techniques, including the use of longer wavelengths (1064 nm), acousto-optic modulation, and heterodyne detection to enhance CBF sensitivity and reduce extracerebral contamination. In each domain of improvement, we develop theory to describe the detected optical signals, advance hardware to enable measurements, and characterize the performance of the developed systems in phantom and human subject experiments. Each different improvement - wavelength extension, ultrasound sonification, heterodyne detection, and time-resolved detection - has its own advantage in terms of depth sensitivity, signal-to-noise ratio, and hardware/software complexity. As such, the techniques have the potential to be mixed and matched to increase sensitivity to CBF and dramatically improve the SNR of the measurement to enable non-invasive, bedside measurements."],"dc:description.degree":["Ph.D."],"dc:format.mimetype":["application/pdf"],"dc:identifier.orcid":["https://orcid.org/0000-0001-5810-0459"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/147506"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["Interferometric, acousto-optic modulated diffuse correlation spectroscopy @ 1064 nm (AOM-iDCS) toward higher sensitivity, non-invasive measurement of cerebral blood flow"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Doctoral","Doctor of Philosophy"]},"updated_at":"2026-11-27T23:27:43Z"}