{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/151930"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/151930","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Characterizing Failure Modes in Continuous Flow Microfluidic Pumps","abstract":"Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures.","abstract_html":"Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures.","abstract_has_math":false,"creators":["Jia, Delace (Delace L.)"],"institution":"Massachusetts Institute of Technology","degree_name":"Bachelor","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Kamm, Roger D."],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-06","date_published":"2023-06","updated_at":"2026-11-27T06:22:13Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/151930","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/151930","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F151930","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F151930","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kamm, Roger D."]},{"key":"dc:creator","label":"Author","values":["Jia, Delace (Delace L.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-08-23T16:19:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-23T16:19:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-06"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2023-07-18T16:17:20.327Z"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Bachelor","Bachelor of Science in Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/151930"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2b5bf2f6-79f5-4689-9c92-1904805c78c8\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Characterizing Failure Modes in Continuous Flow Microfluidic Pumps</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-06</PublicationDate> <Authors> <Author> <DisplayName>Jia, Delace (Delace L.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description.abstract","label":"Abstract","values":["Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterizing Failure Modes in Continuous Flow Microfluidic Pumps"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2b5bf2f6-79f5-4689-9c92-1904805c78c8\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Characterizing Failure Modes in Continuous Flow Microfluidic Pumps</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2023-06</PublicationDate> <Authors> <Author> <DisplayName>Jia, Delace (Delace L.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Kamm, Roger D."],"dc:creator":["Jia, Delace (Delace L.)"],"dc:date.accessioned":["2023-08-23T16:19:50Z"],"dc:date.available":["2023-08-23T16:19:50Z"],"dc:date.issued":["2023-06"],"dc:date.submitted":["2023-07-18T16:17:20.327Z"],"dc:description.abstract":["Microphysiological systems provide novel platforms for drug testing and therapeutic target discovery, through their three-dimensional morphologies that mimic specific tissues and organs. In concurrence with these systems, microfluidic channels allow for a sufficient supply of nutrients to the cell culture; by creating pressure gradients across the system, they allow for fluid flow through the tissue medium. A microfluidic pump, Microheart, for continuous flow through microphysiological systems was presented in Offeddu, 2021. The design introduced a novel, low-cost method of delivering cell culture media at low flow rates. While the Microheart pumps in practice have qualitatively provided an indication of media flow through microphysiological systems, the yield rate of production, and efficacy of their function have not been fully characterized. The following study explores the potential failure modes of the Microheart pump, and characterizes the pump consistency over the standard time of function with cell cultures."],"dc:description.degree":["S.B."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/151930"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["Characterizing Failure Modes in Continuous Flow Microfluidic Pumps"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Bachelor","Bachelor of Science in Mechanical Engineering"]},"updated_at":"2026-11-27T06:22:13Z"}