{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/155875"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/155875","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design Exploration for Biological Fluid Sampling Platform","abstract":"This work explores the design of an implantable, peristaltic pumping platform for chronic sampling of neuropeptides. The project drew inspiration from a pumping platform previously developed in the Cima Lab. Users have reported that the previous platform is difficult to use. The pump is also nearly 47x too large to be implanted in rats, which restricts its use to sedated or tethered animals. The project aimed to improve usability and enable implantation. Alternative fluidic junction methods and alternative actuation modes were investigated. The new junction design improves usability by enabling repeated, reversible attachment to the pump. The new, more efficient pump design reduces the pump volume by 49x, enabling implantation.","abstract_html":"This work explores the design of an implantable, peristaltic pumping platform for chronic sampling of neuropeptides. The project drew inspiration from a pumping platform previously developed in the Cima Lab. Users have reported that the previous platform is difficult to use. The pump is also nearly 47x too large to be implanted in rats, which restricts its use to sedated or tethered animals. The project aimed to improve usability and enable implantation. Alternative fluidic junction methods and alternative actuation modes were investigated. The new junction design improves usability by enabling repeated, reversible attachment to the pump. The new, more efficient pump design reduces the pump volume by 49x, enabling implantation.","abstract_has_math":false,"creators":["Higginbotham, Haley O'Hara"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Cima, Michael J."],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-05","date_published":"2024-05","updated_at":"2026-11-29T16:52:35Z","subjects":[],"languages":[],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)","Copyright retained by author(s)"],"rights_urls":["https://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0001-7687-3754"],"render_values":[{"text":"0000-0001-7687-3754","href":"https://orcid.org/0000-0001-7687-3754","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/155875","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/155875","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F155875","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F155875","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Cima, Michael J."]},{"key":"dc:creator","label":"Author","values":["Higginbotham, Haley O'Hara"]},{"key":"dc:identifier.orcid","label":"ORCID","values":["0000-0001-7687-3754"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-08-01T19:02:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-08-01T19:02:52Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2024-06-13T16:46:39.083Z"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master","Master of Science in Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://creativecommons.org/licenses/by-nc-nd/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/155875"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"8c05e856-55a7-4f13-8459-0aa4be301c25\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Design Exploration for Biological Fluid Sampling Platform</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2024-05</PublicationDate> <Authors> <Author> <DisplayName>Higginbotham, Haley O'Hara</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nc-nd/4.0/</License> <Abstract>This work explores the design of an implantable, peristaltic pumping platform for chronic sampling of neuropeptides. The project drew inspiration from a pumping platform previously developed in the Cima Lab. Users have reported that the previous platform is difficult to use. The pump is also nearly 47x too large to be implanted in rats, which restricts its use to sedated or tethered animals. The project aimed to improve usability and enable implantation. Alternative fluidic junction methods and alternative actuation modes were investigated. The new junction design improves usability by enabling repeated, reversible attachment to the pump. The new, more efficient pump design reduces the pump volume by 49x, enabling implantation.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description.abstract","label":"Abstract","values":["This work explores the design of an implantable, peristaltic pumping platform for chronic sampling of neuropeptides. The project drew inspiration from a pumping platform previously developed in the Cima Lab. Users have reported that the previous platform is difficult to use. The pump is also nearly 47x too large to be implanted in rats, which restricts its use to sedated or tethered animals. The project aimed to improve usability and enable implantation. Alternative fluidic junction methods and alternative actuation modes were investigated. The new junction design improves usability by enabling repeated, reversible attachment to the pump. The new, more efficient pump design reduces the pump volume by 49x, enabling implantation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design Exploration for Biological Fluid Sampling Platform"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"8c05e856-55a7-4f13-8459-0aa4be301c25\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Design Exploration for Biological Fluid Sampling Platform</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2024-05</PublicationDate> <Authors> <Author> <DisplayName>Higginbotham, Haley O'Hara</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://creativecommons.org/licenses/by-nc-nd/4.0/</License> <Abstract>This work explores the design of an implantable, peristaltic pumping platform for chronic sampling of neuropeptides. The project drew inspiration from a pumping platform previously developed in the Cima Lab. Users have reported that the previous platform is difficult to use. The pump is also nearly 47x too large to be implanted in rats, which restricts its use to sedated or tethered animals. The project aimed to improve usability and enable implantation. Alternative fluidic junction methods and alternative actuation modes were investigated. The new junction design improves usability by enabling repeated, reversible attachment to the pump. The new, more efficient pump design reduces the pump volume by 49x, enabling implantation.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Cima, Michael J."],"dc:creator":["Higginbotham, Haley O'Hara"],"dc:date.accessioned":["2024-08-01T19:02:52Z"],"dc:date.available":["2024-08-01T19:02:52Z"],"dc:date.issued":["2024-05"],"dc:date.submitted":["2024-06-13T16:46:39.083Z"],"dc:description.abstract":["This work explores the design of an implantable, peristaltic pumping platform for chronic sampling of neuropeptides. The project drew inspiration from a pumping platform previously developed in the Cima Lab. Users have reported that the previous platform is difficult to use. The pump is also nearly 47x too large to be implanted in rats, which restricts its use to sedated or tethered animals. The project aimed to improve usability and enable implantation. Alternative fluidic junction methods and alternative actuation modes were investigated. The new junction design improves usability by enabling repeated, reversible attachment to the pump. The new, more efficient pump design reduces the pump volume by 49x, enabling implantation."],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.orcid":["0000-0001-7687-3754"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/155875"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0)","Copyright retained by author(s)"],"dc:rights.uri":["https://creativecommons.org/licenses/by-nc-nd/4.0/"],"dc:title":["Design Exploration for Biological Fluid Sampling Platform"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master","Master of Science in Mechanical Engineering"]},"updated_at":"2026-11-29T16:52:35Z"}