{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/157733"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/157733","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Towards a Single Bio-molecule Detector Based on CMOS Nanofluidic Platform","abstract":"Cytokines secretion is a core component of the function of many cell therapy products: It affects the tissue repair capacity of induced Pluripotent Stem Cells (iPSCs) and Mesenchymal Stem cells (MSCs) and the tumorigenicity of Chimeric Antigen Receptor (CAR) T-cell therapies. Ideally, we would be able to continuously monitor the secretome of these cell therapies as they are transformed and expanded in manufacturing.However, state-of-theart techniques for monitoring typically low concentrations of cytokines require either Mass Spectroscopy (MS) or immunoassays like Enzyme-linked Immunosorbent Assay (ELISA). We propose the use of CMOS technology to build a proteomic platform with a single biomolecule resolution. A prototype chip has been designed and fabricated using standard foundary process incorporating a new implementation of a Solid State Nanopore (SSN) of size 55nm×162nm×100nm (w×l×h) with nanofluidic access channels that bridge the buffer solution between the assay space in the packaging structure – a poly carbonate/Polydimethylsiloxane (PDMS) package- and the nanopore on the chip. A silicon Single Photon Avalanche Detectors (SPADs) was also implemented and placed near the nanochannels to utilize fluorescence labeling imaging techniques. In addition, a read-out amplifier that achieves a midband gain of 36.2 dB at a 3 dB bandwidth of 0.1-3.6 MHz is also implemented on the same silicon die, paving the way to superior performance compared to ionic current read-out systems used earlier for electrical biomolecule detection, thanks to low parasitics as a result of integration. The aforementioned modalities integrated on a single chip open the space for the use of CMOS platforms in the electrical and optical interrogation of biomolecules, opening a new horizon for near real-time biomarker assays. The following thesis builds on earlier work that was performed in [1][2] with the objective of expanding on different techniques to interface and characterize the performance of these modalities, especially after post-processing the chips with the aid of tools at MIT.nano. The thesis explores the further deployment of integrated SPAD in a Fluorescence Lifetime Imaging (FLIM) system to image fluorescence-labeled molecules, showcasing the capabilities of the CMOS nanofluidic platform to detect biomarkers such as cytokines.","abstract_html":"Cytokines secretion is a core component of the function of many cell therapy products: It affects the tissue repair capacity of induced Pluripotent Stem Cells (iPSCs) and Mesenchymal Stem cells (MSCs) and the tumorigenicity of Chimeric Antigen Receptor (CAR) T-cell therapies. Ideally, we would be able to continuously monitor the secretome of these cell therapies as they are transformed and expanded in manufacturing.However, state-of-theart techniques for monitoring typically low concentrations of cytokines require either Mass Spectroscopy (MS) or immunoassays like Enzyme-linked Immunosorbent Assay (ELISA). We propose the use of CMOS technology to build a proteomic platform with a single biomolecule resolution. A prototype chip has been designed and fabricated using standard foundary process incorporating a new implementation of a Solid State Nanopore (SSN) of size 55nm×162nm×100nm (w×l×h) with nanofluidic access channels that bridge the buffer solution between the assay space in the packaging structure – a poly carbonate/Polydimethylsiloxane (PDMS) package- and the nanopore on the chip. A silicon Single Photon Avalanche Detectors (SPADs) was also implemented and placed near the nanochannels to utilize fluorescence labeling imaging techniques. In addition, a read-out amplifier that achieves a midband gain of 36.2 dB at a 3 dB bandwidth of 0.1-3.6 MHz is also implemented on the same silicon die, paving the way to superior performance compared to ionic current read-out systems used earlier for electrical biomolecule detection, thanks to low parasitics as a result of integration. The aforementioned modalities integrated on a single chip open the space for the use of CMOS platforms in the electrical and optical interrogation of biomolecules, opening a new horizon for near real-time biomarker assays. The following thesis builds on earlier work that was performed in [1][2] with the objective of expanding on different techniques to interface and characterize the performance of these modalities, especially after post-processing the chips with the aid of tools at MIT.nano. The thesis explores the further deployment of integrated SPAD in a Fluorescence Lifetime Imaging (FLIM) system to image fluorescence-labeled molecules, showcasing the capabilities of the CMOS nanofluidic platform to detect biomarkers such as cytokines.","abstract_has_math":false,"creators":["Zikrallah, Ahmed S."],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ram, Rajeev J."],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-09","date_published":"2024-09","updated_at":"2026-11-27T07:24:52Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[],"person_identifier_entries":[{"key":"dc:identifier.orcid","label":"ORCID","values":["https://orcid.org/0009-0007-6842-5397"],"render_values":[{"text":"0009-0007-6842-5397","href":"https://orcid.org/0009-0007-6842-5397","code":true}]}]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/157733","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/157733","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F157733","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F157733","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ram, Rajeev J."]},{"key":"dc:creator","label":"Author","values":["Zikrallah, Ahmed S."]},{"key":"dc:identifier.orcid","label":"ORCID","values":["https://orcid.org/0009-0007-6842-5397"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-12-02T21:15:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-12-02T21:15:46Z"]},{"key":"dc:date.issued","label":"Date","values":["2024-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2024-11-19T19:17:23.295Z"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master","Master of Science in Media Arts and Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/157733"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"42acd5a3-22c7-40db-a7ab-c4692b47266c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Towards a Single Bio-molecule Detector Based on CMOS Nanofluidic Platform</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2024-09</PublicationDate> <Authors> <Author> <DisplayName>Zikrallah, Ahmed S.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Cytokines secretion is a core component of the function of many cell therapy products: It affects the tissue repair capacity of induced Pluripotent Stem Cells (iPSCs) and Mesenchymal Stem cells (MSCs) and the tumorigenicity of Chimeric Antigen Receptor (CAR) T-cell therapies. Ideally, we would be able to continuously monitor the secretome of these cell therapies as they are transformed and expanded in manufacturing.However, state-of-theart techniques for monitoring typically low concentrations of cytokines require either Mass Spectroscopy (MS) or immunoassays like Enzyme-linked Immunosorbent Assay (ELISA). We propose the use of CMOS technology to build a proteomic platform with a single biomolecule resolution. A prototype chip has been designed and fabricated using standard foundary process incorporating a new implementation of a Solid State Nanopore (SSN) of size 55nm×162nm×100nm (w×l×h) with nanofluidic access channels that bridge the buffer solution between the assay space in the packaging structure – a poly carbonate/Polydimethylsiloxane (PDMS) package- and the nanopore on the chip. A silicon Single Photon Avalanche Detectors (SPADs) was also implemented and placed near the nanochannels to utilize fluorescence labeling imaging techniques. In addition, a read-out amplifier that achieves a midband gain of 36.2 dB at a 3 dB bandwidth of 0.1-3.6 MHz is also implemented on the same silicon die, paving the way to superior performance compared to ionic current read-out systems used earlier for electrical biomolecule detection, thanks to low parasitics as a result of integration. The aforementioned modalities integrated on a single chip open the space for the use of CMOS platforms in the electrical and optical interrogation of biomolecules, opening a new horizon for near real-time biomarker assays. The following thesis builds on earlier work that was performed in [1][2] with the objective of expanding on different techniques to interface and characterize the performance of these modalities, especially after post-processing the chips with the aid of tools at MIT.nano. The thesis explores the further deployment of integrated SPAD in a Fluorescence Lifetime Imaging (FLIM) system to image fluorescence-labeled molecules, showcasing the capabilities of the CMOS nanofluidic platform to detect biomarkers such as cytokines.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description.abstract","label":"Abstract","values":["Cytokines secretion is a core component of the function of many cell therapy products: It affects the tissue repair capacity of induced Pluripotent Stem Cells (iPSCs) and Mesenchymal Stem cells (MSCs) and the tumorigenicity of Chimeric Antigen Receptor (CAR) T-cell therapies. Ideally, we would be able to continuously monitor the secretome of these cell therapies as they are transformed and expanded in manufacturing.However, state-of-theart techniques for monitoring typically low concentrations of cytokines require either Mass Spectroscopy (MS) or immunoassays like Enzyme-linked Immunosorbent Assay (ELISA). We propose the use of CMOS technology to build a proteomic platform with a single biomolecule resolution. A prototype chip has been designed and fabricated using standard foundary process incorporating a new implementation of a Solid State Nanopore (SSN) of size 55nm×162nm×100nm (w×l×h) with nanofluidic access channels that bridge the buffer solution between the assay space in the packaging structure – a poly carbonate/Polydimethylsiloxane (PDMS) package- and the nanopore on the chip. A silicon Single Photon Avalanche Detectors (SPADs) was also implemented and placed near the nanochannels to utilize fluorescence labeling imaging techniques. In addition, a read-out amplifier that achieves a midband gain of 36.2 dB at a 3 dB bandwidth of 0.1-3.6 MHz is also implemented on the same silicon die, paving the way to superior performance compared to ionic current read-out systems used earlier for electrical biomolecule detection, thanks to low parasitics as a result of integration. The aforementioned modalities integrated on a single chip open the space for the use of CMOS platforms in the electrical and optical interrogation of biomolecules, opening a new horizon for near real-time biomarker assays. The following thesis builds on earlier work that was performed in [1][2] with the objective of expanding on different techniques to interface and characterize the performance of these modalities, especially after post-processing the chips with the aid of tools at MIT.nano. The thesis explores the further deployment of integrated SPAD in a Fluorescence Lifetime Imaging (FLIM) system to image fluorescence-labeled molecules, showcasing the capabilities of the CMOS nanofluidic platform to detect biomarkers such as cytokines."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Towards a Single Bio-molecule Detector Based on CMOS Nanofluidic Platform"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"42acd5a3-22c7-40db-a7ab-c4692b47266c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Towards a Single Bio-molecule Detector Based on CMOS Nanofluidic Platform</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2024-09</PublicationDate> <Authors> <Author> <DisplayName>Zikrallah, Ahmed S.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Cytokines secretion is a core component of the function of many cell therapy products: It affects the tissue repair capacity of induced Pluripotent Stem Cells (iPSCs) and Mesenchymal Stem cells (MSCs) and the tumorigenicity of Chimeric Antigen Receptor (CAR) T-cell therapies. Ideally, we would be able to continuously monitor the secretome of these cell therapies as they are transformed and expanded in manufacturing.However, state-of-theart techniques for monitoring typically low concentrations of cytokines require either Mass Spectroscopy (MS) or immunoassays like Enzyme-linked Immunosorbent Assay (ELISA). We propose the use of CMOS technology to build a proteomic platform with a single biomolecule resolution. A prototype chip has been designed and fabricated using standard foundary process incorporating a new implementation of a Solid State Nanopore (SSN) of size 55nm×162nm×100nm (w×l×h) with nanofluidic access channels that bridge the buffer solution between the assay space in the packaging structure – a poly carbonate/Polydimethylsiloxane (PDMS) package- and the nanopore on the chip. A silicon Single Photon Avalanche Detectors (SPADs) was also implemented and placed near the nanochannels to utilize fluorescence labeling imaging techniques. In addition, a read-out amplifier that achieves a midband gain of 36.2 dB at a 3 dB bandwidth of 0.1-3.6 MHz is also implemented on the same silicon die, paving the way to superior performance compared to ionic current read-out systems used earlier for electrical biomolecule detection, thanks to low parasitics as a result of integration. The aforementioned modalities integrated on a single chip open the space for the use of CMOS platforms in the electrical and optical interrogation of biomolecules, opening a new horizon for near real-time biomarker assays. The following thesis builds on earlier work that was performed in [1][2] with the objective of expanding on different techniques to interface and characterize the performance of these modalities, especially after post-processing the chips with the aid of tools at MIT.nano. The thesis explores the further deployment of integrated SPAD in a Fluorescence Lifetime Imaging (FLIM) system to image fluorescence-labeled molecules, showcasing the capabilities of the CMOS nanofluidic platform to detect biomarkers such as cytokines.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Ram, Rajeev J."],"dc:creator":["Zikrallah, Ahmed S."],"dc:date.accessioned":["2024-12-02T21:15:46Z"],"dc:date.available":["2024-12-02T21:15:46Z"],"dc:date.issued":["2024-09"],"dc:date.submitted":["2024-11-19T19:17:23.295Z"],"dc:description.abstract":["Cytokines secretion is a core component of the function of many cell therapy products: It affects the tissue repair capacity of induced Pluripotent Stem Cells (iPSCs) and Mesenchymal Stem cells (MSCs) and the tumorigenicity of Chimeric Antigen Receptor (CAR) T-cell therapies. Ideally, we would be able to continuously monitor the secretome of these cell therapies as they are transformed and expanded in manufacturing.However, state-of-theart techniques for monitoring typically low concentrations of cytokines require either Mass Spectroscopy (MS) or immunoassays like Enzyme-linked Immunosorbent Assay (ELISA). We propose the use of CMOS technology to build a proteomic platform with a single biomolecule resolution. A prototype chip has been designed and fabricated using standard foundary process incorporating a new implementation of a Solid State Nanopore (SSN) of size 55nm×162nm×100nm (w×l×h) with nanofluidic access channels that bridge the buffer solution between the assay space in the packaging structure – a poly carbonate/Polydimethylsiloxane (PDMS) package- and the nanopore on the chip. A silicon Single Photon Avalanche Detectors (SPADs) was also implemented and placed near the nanochannels to utilize fluorescence labeling imaging techniques. In addition, a read-out amplifier that achieves a midband gain of 36.2 dB at a 3 dB bandwidth of 0.1-3.6 MHz is also implemented on the same silicon die, paving the way to superior performance compared to ionic current read-out systems used earlier for electrical biomolecule detection, thanks to low parasitics as a result of integration. The aforementioned modalities integrated on a single chip open the space for the use of CMOS platforms in the electrical and optical interrogation of biomolecules, opening a new horizon for near real-time biomarker assays. The following thesis builds on earlier work that was performed in [1][2] with the objective of expanding on different techniques to interface and characterize the performance of these modalities, especially after post-processing the chips with the aid of tools at MIT.nano. The thesis explores the further deployment of integrated SPAD in a Fluorescence Lifetime Imaging (FLIM) system to image fluorescence-labeled molecules, showcasing the capabilities of the CMOS nanofluidic platform to detect biomarkers such as cytokines."],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.orcid":["https://orcid.org/0009-0007-6842-5397"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/157733"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["Towards a Single Bio-molecule Detector Based on CMOS Nanofluidic Platform"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master","Master of Science in Media Arts and Sciences"]},"updated_at":"2026-11-27T07:24:52Z"}