{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/163342"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/163342","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A Techno-Economic Assessment of Hybrid Renewable Energy and Battery Storage Systems for Data Centers","abstract":"As the demand for data centers continues to grow, so does their energy consumption, making it increasingly important to develop sustainable and cost-effective strategies for powering them with carbon-free electricity. This thesis explores a techno-economic modeling framework that evaluates combinations of solar, wind, and battery energy storage systems to assess their ability to meet a data center’s electricity demand with on-site renewable generation. The model fills a gap in current literature by focusing on real-time energy matching using co-located infrastructure, rather than traditional off-site procurement methods like power purchase agreements and renewable energy credits. Using real-world weather and price data, the simulation calculates hourly generation, storage behavior, and grid interactions across a 20-year period. A financial model then calculates the levelized cost of energy (LCOE) for each system configuration. Results show that wind energy generally provides the lowest-cost renewable supply option, while hybrid solar and wind configurations improve renewable penetration. Battery storage plays a key role in shifting excess generation to periods of undersupply, but its economic viability depends on system sizing. Across different system configurations, renewable penetration ranged from 31.3% to 97.8%, while LCOE varied from $27.5/MWh to over $100/MWh, illustrating the trade-offs between cost and grid independence. By providing a structured analysis of the trade-offs between renewable penetration and cost, this research offers insight into how data centers and other energy-intensive facilities can design dedicated carbon-free energy systems. The findings underscore the importance of balancing resource diversity and storage investment to achieve decarbonization goals while maintaining economic viability.","abstract_html":"As the demand for data centers continues to grow, so does their energy consumption, making it increasingly important to develop sustainable and cost-effective strategies for powering them with carbon-free electricity. This thesis explores a techno-economic modeling framework that evaluates combinations of solar, wind, and battery energy storage systems to assess their ability to meet a data center’s electricity demand with on-site renewable generation. The model fills a gap in current literature by focusing on real-time energy matching using co-located infrastructure, rather than traditional off-site procurement methods like power purchase agreements and renewable energy credits. Using real-world weather and price data, the simulation calculates hourly generation, storage behavior, and grid interactions across a 20-year period. A financial model then calculates the levelized cost of energy (LCOE) for each system configuration. Results show that wind energy generally provides the lowest-cost renewable supply option, while hybrid solar and wind configurations improve renewable penetration. Battery storage plays a key role in shifting excess generation to periods of undersupply, but its economic viability depends on system sizing. Across different system configurations, renewable penetration ranged from 31.3% to 97.8%, while LCOE varied from $27.5/MWh to over $100/MWh, illustrating the trade-offs between cost and grid independence. By providing a structured analysis of the trade-offs between renewable penetration and cost, this research offers insight into how data centers and other energy-intensive facilities can design dedicated carbon-free energy systems. The findings underscore the importance of balancing resource diversity and storage investment to achieve decarbonization goals while maintaining economic viability.","abstract_has_math":true,"creators":["Sirgo, Alex"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Parsons, John","Deng, Sili"],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-05","date_published":"2025-05","updated_at":"2026-11-29T16:51:21Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/163342","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/163342","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F163342","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F163342","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Parsons, John","Deng, Sili"]},{"key":"dc:creator","label":"Author","values":["Sirgo, Alex"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-10-21T13:20:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-10-21T13:20:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-06-23T17:08:44.492Z"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master","Master of Science in Mechanical Engineering","Master of Business Administration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/163342"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"81452b6d-c787-4c32-acbd-fa7dd8e8bee9\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>A Techno-Economic Assessment of Hybrid Renewable Energy and Battery Storage Systems for Data Centers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-05</PublicationDate> <Authors> <Author> <DisplayName>Sirgo, Alex</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>As the demand for data centers continues to grow, so does their energy consumption, making it increasingly important to develop sustainable and cost-effective strategies for powering them with carbon-free electricity. This thesis explores a techno-economic modeling framework that evaluates combinations of solar, wind, and battery energy storage systems to assess their ability to meet a data center’s electricity demand with on-site renewable generation. The model fills a gap in current literature by focusing on real-time energy matching using co-located infrastructure, rather than traditional off-site procurement methods like power purchase agreements and renewable energy credits. Using real-world weather and price data, the simulation calculates hourly generation, storage behavior, and grid interactions across a 20-year period. A financial model then calculates the levelized cost of energy (LCOE) for each system configuration. Results show that wind energy generally provides the lowest-cost renewable supply option, while hybrid solar and wind configurations improve renewable penetration. Battery storage plays a key role in shifting excess generation to periods of undersupply, but its economic viability depends on system sizing. Across different system configurations, renewable penetration ranged from 31.3% to 97.8%, while LCOE varied from $27.5/MWh to over $100/MWh, illustrating the trade-offs between cost and grid independence. By providing a structured analysis of the trade-offs between renewable penetration and cost, this research offers insight into how data centers and other energy-intensive facilities can design dedicated carbon-free energy systems. The findings underscore the importance of balancing resource diversity and storage investment to achieve decarbonization goals while maintaining economic viability.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description.abstract","label":"Abstract","values":["As the demand for data centers continues to grow, so does their energy consumption, making it increasingly important to develop sustainable and cost-effective strategies for powering them with carbon-free electricity. This thesis explores a techno-economic modeling framework that evaluates combinations of solar, wind, and battery energy storage systems to assess their ability to meet a data center’s electricity demand with on-site renewable generation. The model fills a gap in current literature by focusing on real-time energy matching using co-located infrastructure, rather than traditional off-site procurement methods like power purchase agreements and renewable energy credits. Using real-world weather and price data, the simulation calculates hourly generation, storage behavior, and grid interactions across a 20-year period. A financial model then calculates the levelized cost of energy (LCOE) for each system configuration. Results show that wind energy generally provides the lowest-cost renewable supply option, while hybrid solar and wind configurations improve renewable penetration. Battery storage plays a key role in shifting excess generation to periods of undersupply, but its economic viability depends on system sizing. Across different system configurations, renewable penetration ranged from 31.3% to 97.8%, while LCOE varied from $27.5/MWh to over $100/MWh, illustrating the trade-offs between cost and grid independence. By providing a structured analysis of the trade-offs between renewable penetration and cost, this research offers insight into how data centers and other energy-intensive facilities can design dedicated carbon-free energy systems. The findings underscore the importance of balancing resource diversity and storage investment to achieve decarbonization goals while maintaining economic viability."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M.","M.B.A."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Techno-Economic Assessment of Hybrid Renewable Energy and Battery Storage Systems for Data Centers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"81452b6d-c787-4c32-acbd-fa7dd8e8bee9\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>A Techno-Economic Assessment of Hybrid Renewable Energy and Battery Storage Systems for Data Centers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-05</PublicationDate> <Authors> <Author> <DisplayName>Sirgo, Alex</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>As the demand for data centers continues to grow, so does their energy consumption, making it increasingly important to develop sustainable and cost-effective strategies for powering them with carbon-free electricity. This thesis explores a techno-economic modeling framework that evaluates combinations of solar, wind, and battery energy storage systems to assess their ability to meet a data center’s electricity demand with on-site renewable generation. The model fills a gap in current literature by focusing on real-time energy matching using co-located infrastructure, rather than traditional off-site procurement methods like power purchase agreements and renewable energy credits. Using real-world weather and price data, the simulation calculates hourly generation, storage behavior, and grid interactions across a 20-year period. A financial model then calculates the levelized cost of energy (LCOE) for each system configuration. Results show that wind energy generally provides the lowest-cost renewable supply option, while hybrid solar and wind configurations improve renewable penetration. Battery storage plays a key role in shifting excess generation to periods of undersupply, but its economic viability depends on system sizing. Across different system configurations, renewable penetration ranged from 31.3% to 97.8%, while LCOE varied from $27.5/MWh to over $100/MWh, illustrating the trade-offs between cost and grid independence. By providing a structured analysis of the trade-offs between renewable penetration and cost, this research offers insight into how data centers and other energy-intensive facilities can design dedicated carbon-free energy systems. The findings underscore the importance of balancing resource diversity and storage investment to achieve decarbonization goals while maintaining economic viability.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Parsons, John","Deng, Sili"],"dc:creator":["Sirgo, Alex"],"dc:date.accessioned":["2025-10-21T13:20:16Z"],"dc:date.available":["2025-10-21T13:20:16Z"],"dc:date.issued":["2025-05"],"dc:date.submitted":["2025-06-23T17:08:44.492Z"],"dc:description.abstract":["As the demand for data centers continues to grow, so does their energy consumption, making it increasingly important to develop sustainable and cost-effective strategies for powering them with carbon-free electricity. This thesis explores a techno-economic modeling framework that evaluates combinations of solar, wind, and battery energy storage systems to assess their ability to meet a data center’s electricity demand with on-site renewable generation. The model fills a gap in current literature by focusing on real-time energy matching using co-located infrastructure, rather than traditional off-site procurement methods like power purchase agreements and renewable energy credits. Using real-world weather and price data, the simulation calculates hourly generation, storage behavior, and grid interactions across a 20-year period. A financial model then calculates the levelized cost of energy (LCOE) for each system configuration. Results show that wind energy generally provides the lowest-cost renewable supply option, while hybrid solar and wind configurations improve renewable penetration. Battery storage plays a key role in shifting excess generation to periods of undersupply, but its economic viability depends on system sizing. Across different system configurations, renewable penetration ranged from 31.3% to 97.8%, while LCOE varied from $27.5/MWh to over $100/MWh, illustrating the trade-offs between cost and grid independence. By providing a structured analysis of the trade-offs between renewable penetration and cost, this research offers insight into how data centers and other energy-intensive facilities can design dedicated carbon-free energy systems. The findings underscore the importance of balancing resource diversity and storage investment to achieve decarbonization goals while maintaining economic viability."],"dc:description.degree":["S.M.","M.B.A."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/163342"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["A Techno-Economic Assessment of Hybrid Renewable Energy and Battery Storage Systems for Data Centers"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master","Master of Science in Mechanical Engineering","Master of Business Administration"]},"updated_at":"2026-11-29T16:51:21Z"}