{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/165177"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/165177","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Integrated Materials for Ion Transport Management in Anion Exchange Membrane Electrolyzers","abstract":"Electrochemical CO₂ separation systems leveraging anion exchange membranes (AEMs) offer significant energetic advantages over traditional bipolar membrane electrodialysis (BPMED), but suffer from hydroxide crossover, which reduces current efficiency (CE) and system performance. This work explores the transport dynamics of carbonate and hydroxide ions in AEM systems and introduces a hybrid PES-AEM bilayer membrane architecture to mitigate hydroxide crossover while preserving sufficient CO₂ recovery. We demonstrate that the bilayer system achieves a reduced relative transport factor (R = 1.4) and enables up to 3.8x improvement in CE compared to conventional AEM systems at realistic capture conditions. Further analysis reveals that transport properties in the least conductive domain of a multi-membrane system dominate overall behavior, allowing non-selective, low-conductivity materials such as porous PES to reduce hydroxide crossover effects. This study outlines key membrane material parameters influencing relative ionic transport and highlights the potential of hybrid architectures to unlock energy-efficient CO₂ electrochemical regeneration for direct air capture (DAC) integration.","abstract_html":"Electrochemical CO₂ separation systems leveraging anion exchange membranes (AEMs) offer significant energetic advantages over traditional bipolar membrane electrodialysis (BPMED), but suffer from hydroxide crossover, which reduces current efficiency (CE) and system performance. This work explores the transport dynamics of carbonate and hydroxide ions in AEM systems and introduces a hybrid PES-AEM bilayer membrane architecture to mitigate hydroxide crossover while preserving sufficient CO₂ recovery. We demonstrate that the bilayer system achieves a reduced relative transport factor (R = 1.4) and enables up to 3.8x improvement in CE compared to conventional AEM systems at realistic capture conditions. Further analysis reveals that transport properties in the least conductive domain of a multi-membrane system dominate overall behavior, allowing non-selective, low-conductivity materials such as porous PES to reduce hydroxide crossover effects. This study outlines key membrane material parameters influencing relative ionic transport and highlights the potential of hybrid architectures to unlock energy-efficient CO₂ electrochemical regeneration for direct air capture (DAC) integration.","abstract_has_math":false,"creators":["Aamer, Zara"],"institution":"Massachusetts Institute of Technology","degree_name":"Master","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Varanasi, Kripa K."],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025-09","date_published":"2025-09","updated_at":"2026-11-27T04:18:51Z","subjects":[],"languages":[],"rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"rights_urls":["https://rightsstatements.org/page/InC-EDU/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/165177","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/165177","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F165177","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F165177","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Varanasi, Kripa K."]},{"key":"dc:creator","label":"Author","values":["Aamer, Zara"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-16T15:47:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-03-16T15:47:34Z"]},{"key":"dc:date.issued","label":"Date","values":["2025-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2025-09-18T13:55:07.129Z"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master","Master of Science in Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"]},{"key":"dc:rights.uri","label":"Rights URI","values":["https://rightsstatements.org/page/InC-EDU/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/1721.1/165177"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1241ad9d-1e84-4d08-8e35-2294d798f348\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Integrated Materials for Ion Transport Management in Anion Exchange Membrane Electrolyzers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-09</PublicationDate> <Authors> <Author> <DisplayName>Aamer, Zara</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Electrochemical CO₂ separation systems leveraging anion exchange membranes (AEMs) offer significant energetic advantages over traditional bipolar membrane electrodialysis (BPMED), but suffer from hydroxide crossover, which reduces current efficiency (CE) and system performance. This work explores the transport dynamics of carbonate and hydroxide ions in AEM systems and introduces a hybrid PES-AEM bilayer membrane architecture to mitigate hydroxide crossover while preserving sufficient CO₂ recovery. We demonstrate that the bilayer system achieves a reduced relative transport factor (R = 1.4) and enables up to 3.8x improvement in CE compared to conventional AEM systems at realistic capture conditions. Further analysis reveals that transport properties in the least conductive domain of a multi-membrane system dominate overall behavior, allowing non-selective, low-conductivity materials such as porous PES to reduce hydroxide crossover effects. This study outlines key membrane material parameters influencing relative ionic transport and highlights the potential of hybrid architectures to unlock energy-efficient CO₂ electrochemical regeneration for direct air capture (DAC) integration.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description.abstract","label":"Abstract","values":["Electrochemical CO₂ separation systems leveraging anion exchange membranes (AEMs) offer significant energetic advantages over traditional bipolar membrane electrodialysis (BPMED), but suffer from hydroxide crossover, which reduces current efficiency (CE) and system performance. This work explores the transport dynamics of carbonate and hydroxide ions in AEM systems and introduces a hybrid PES-AEM bilayer membrane architecture to mitigate hydroxide crossover while preserving sufficient CO₂ recovery. We demonstrate that the bilayer system achieves a reduced relative transport factor (R = 1.4) and enables up to 3.8x improvement in CE compared to conventional AEM systems at realistic capture conditions. Further analysis reveals that transport properties in the least conductive domain of a multi-membrane system dominate overall behavior, allowing non-selective, low-conductivity materials such as porous PES to reduce hydroxide crossover effects. This study outlines key membrane material parameters influencing relative ionic transport and highlights the potential of hybrid architectures to unlock energy-efficient CO₂ electrochemical regeneration for direct air capture (DAC) integration."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Integrated Materials for Ion Transport Management in Anion Exchange Membrane Electrolyzers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1241ad9d-1e84-4d08-8e35-2294d798f348\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Title>Integrated Materials for Ion Transport Management in Anion Exchange Membrane Electrolyzers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2025-09</PublicationDate> <Authors> <Author> <DisplayName>Aamer, Zara</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>https://rightsstatements.org/page/InC-EDU/1.0/</License> <Abstract>Electrochemical CO₂ separation systems leveraging anion exchange membranes (AEMs) offer significant energetic advantages over traditional bipolar membrane electrodialysis (BPMED), but suffer from hydroxide crossover, which reduces current efficiency (CE) and system performance. This work explores the transport dynamics of carbonate and hydroxide ions in AEM systems and introduces a hybrid PES-AEM bilayer membrane architecture to mitigate hydroxide crossover while preserving sufficient CO₂ recovery. We demonstrate that the bilayer system achieves a reduced relative transport factor (R = 1.4) and enables up to 3.8x improvement in CE compared to conventional AEM systems at realistic capture conditions. Further analysis reveals that transport properties in the least conductive domain of a multi-membrane system dominate overall behavior, allowing non-selective, low-conductivity materials such as porous PES to reduce hydroxide crossover effects. This study outlines key membrane material parameters influencing relative ionic transport and highlights the potential of hybrid architectures to unlock energy-efficient CO₂ electrochemical regeneration for direct air capture (DAC) integration.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Varanasi, Kripa K."],"dc:creator":["Aamer, Zara"],"dc:date.accessioned":["2026-03-16T15:47:34Z"],"dc:date.available":["2026-03-16T15:47:34Z"],"dc:date.issued":["2025-09"],"dc:date.submitted":["2025-09-18T13:55:07.129Z"],"dc:description.abstract":["Electrochemical CO₂ separation systems leveraging anion exchange membranes (AEMs) offer significant energetic advantages over traditional bipolar membrane electrodialysis (BPMED), but suffer from hydroxide crossover, which reduces current efficiency (CE) and system performance. This work explores the transport dynamics of carbonate and hydroxide ions in AEM systems and introduces a hybrid PES-AEM bilayer membrane architecture to mitigate hydroxide crossover while preserving sufficient CO₂ recovery. We demonstrate that the bilayer system achieves a reduced relative transport factor (R = 1.4) and enables up to 3.8x improvement in CE compared to conventional AEM systems at realistic capture conditions. Further analysis reveals that transport properties in the least conductive domain of a multi-membrane system dominate overall behavior, allowing non-selective, low-conductivity materials such as porous PES to reduce hydroxide crossover effects. This study outlines key membrane material parameters influencing relative ionic transport and highlights the potential of hybrid architectures to unlock energy-efficient CO₂ electrochemical regeneration for direct air capture (DAC) integration."],"dc:description.degree":["S.M."],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/1721.1/165177"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["In Copyright - Educational Use Permitted","Copyright retained by author(s)"],"dc:rights.uri":["https://rightsstatements.org/page/InC-EDU/1.0/"],"dc:title":["Integrated Materials for Ion Transport Management in Anion Exchange Membrane Electrolyzers"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"],"thesis:degree_name":["Master","Master of Science in Mechanical Engineering"]},"updated_at":"2026-11-27T04:18:51Z"}