{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/17499"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/17499","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Boiling heat transfer characteristics of steam generator U-tube fouling","abstract":"The boiling heat transfer characteristics of steam generator u-tube fouling deposits were identified by developing a boiling heat transfer model and determining its accuracy through the comparison of calculated and experimental results. Magnetite deposits were fabricated in the laboratory and were characterized using a variety of techniques. Heat transfer measurements were then taken, so that the effect of deposit parameters, including pore size distribution, porosity, permeability and thickness, as well as the effect of mass flux, heat flux and steam quality were investigated. The model predictions were consistent with the experimental results, differing by an average of ±17.5%. Over the range of parameters studied, pore size distribution dominated the deposit heat transfer. It was found that some fabricated deposits improved the heat transfer of the u-tubes, whereas others hindered it. The data were consistent with that of fouled u-tubes pulled from CANDU steam generators. The conditions of the heat transfer measurements and the fabricated deposits were similar to those of US and Canadian steam generators. Therefore, the conclusions drawn in this study are presumed to apply to the steam generators used in the Canadian and US industries.","abstract_html":"The boiling heat transfer characteristics of steam generator u-tube fouling deposits were identified by developing a boiling heat transfer model and determining its accuracy through the comparison of calculated and experimental results. Magnetite deposits were fabricated in the laboratory and were characterized using a variety of techniques. Heat transfer measurements were then taken, so that the effect of deposit parameters, including pore size distribution, porosity, permeability and thickness, as well as the effect of mass flux, heat flux and steam quality were investigated. The model predictions were consistent with the experimental results, differing by an average of ±17.5%. Over the range of parameters studied, pore size distribution dominated the deposit heat transfer. It was found that some fabricated deposits improved the heat transfer of the u-tubes, whereas others hindered it. The data were consistent with that of fouled u-tubes pulled from CANDU steam generators. The conditions of the heat transfer measurements and the fabricated deposits were similar to those of US and Canadian steam generators. Therefore, the conclusions drawn in this study are presumed to apply to the steam generators used in the Canadian and US industries.","abstract_has_math":false,"creators":["Uhle, Jennifer Lee"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ronald M. Latanision and Neil E. Todreas."],"committee_chairs":[],"committee_members":[],"year":1997,"date_issued":"1997","date_published":"1997","updated_at":"2026-11-27T07:24:42Z","subjects":["Nuclear Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["48181481"],"render_values":[{"text":"48181481","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/17499","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/17499","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F17499","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F17499","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ronald M. Latanision and Neil E. Todreas."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Nuclear Engineering."]},{"key":"dc:creator","label":"Author","values":["Uhle, Jennifer Lee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-07-01T19:22:32Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-07-01T19:22:32Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["1997"]},{"key":"dc:date.issued","label":"Date","values":["1997"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Nuclear Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["48181481"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/17499"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"41bdcf7d-4163-4edd-9072-909b3ea31779\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Boiling heat transfer characteristics of steam generator U-tube fouling</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>1997</PublicationDate> <Authors> <Author> <DisplayName>Uhle, Jennifer Lee</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Nuclear Engineering.</Keyword> <Abstract>The boiling heat transfer characteristics of steam generator u-tube fouling deposits were identified by developing a boiling heat transfer model and determining its accuracy through the comparison of calculated and experimental results. Magnetite deposits were fabricated in the laboratory and were characterized using a variety of techniques. Heat transfer measurements were then taken, so that the effect of deposit parameters, including pore size distribution, porosity, permeability and thickness, as well as the effect of mass flux, heat flux and steam quality were investigated. The model predictions were consistent with the experimental results, differing by an average of ±17.5%. Over the range of parameters studied, pore size distribution dominated the deposit heat transfer. It was found that some fabricated deposits improved the heat transfer of the u-tubes, whereas others hindered it. The data were consistent with that of fouled u-tubes pulled from CANDU steam generators. The conditions of the heat transfer measurements and the fabricated deposits were similar to those of US and Canadian steam generators. Therefore, the conclusions drawn in this study are presumed to apply to the steam generators used in the Canadian and US industries.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (Ph.D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 1997.","Includes bibliographical references (leaves 109-111)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The boiling heat transfer characteristics of steam generator u-tube fouling deposits were identified by developing a boiling heat transfer model and determining its accuracy through the comparison of calculated and experimental results. Magnetite deposits were fabricated in the laboratory and were characterized using a variety of techniques. Heat transfer measurements were then taken, so that the effect of deposit parameters, including pore size distribution, porosity, permeability and thickness, as well as the effect of mass flux, heat flux and steam quality were investigated. The model predictions were consistent with the experimental results, differing by an average of ±17.5%. Over the range of parameters studied, pore size distribution dominated the deposit heat transfer. It was found that some fabricated deposits improved the heat transfer of the u-tubes, whereas others hindered it. The data were consistent with that of fouled u-tubes pulled from CANDU steam generators. The conditions of the heat transfer measurements and the fabricated deposits were similar to those of US and Canadian steam generators. Therefore, the conclusions drawn in this study are presumed to apply to the steam generators used in the Canadian and US industries."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Jennifer L. Uhle."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["141 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Boiling heat transfer characteristics of steam generator U-tube fouling"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"41bdcf7d-4163-4edd-9072-909b3ea31779\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Boiling heat transfer characteristics of steam generator U-tube fouling</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>1997</PublicationDate> <Authors> <Author> <DisplayName>Uhle, Jennifer Lee</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Nuclear Engineering.</Keyword> <Abstract>The boiling heat transfer characteristics of steam generator u-tube fouling deposits were identified by developing a boiling heat transfer model and determining its accuracy through the comparison of calculated and experimental results. Magnetite deposits were fabricated in the laboratory and were characterized using a variety of techniques. Heat transfer measurements were then taken, so that the effect of deposit parameters, including pore size distribution, porosity, permeability and thickness, as well as the effect of mass flux, heat flux and steam quality were investigated. The model predictions were consistent with the experimental results, differing by an average of ±17.5%. Over the range of parameters studied, pore size distribution dominated the deposit heat transfer. It was found that some fabricated deposits improved the heat transfer of the u-tubes, whereas others hindered it. The data were consistent with that of fouled u-tubes pulled from CANDU steam generators. The conditions of the heat transfer measurements and the fabricated deposits were similar to those of US and Canadian steam generators. Therefore, the conclusions drawn in this study are presumed to apply to the steam generators used in the Canadian and US industries.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Ronald M. Latanision and Neil E. Todreas."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Nuclear Engineering."],"dc:creator":["Uhle, Jennifer Lee"],"dc:date.accessioned":["2009-07-01T19:22:32Z"],"dc:date.available":["2009-07-01T19:22:32Z"],"dc:date.copyright":["1997"],"dc:date.issued":["1997"],"dc:description":["Thesis (Ph.D.)--Massachusetts Institute of Technology, Dept. of Nuclear Engineering, 1997.","Includes bibliographical references (leaves 109-111)."],"dc:description.abstract":["The boiling heat transfer characteristics of steam generator u-tube fouling deposits were identified by developing a boiling heat transfer model and determining its accuracy through the comparison of calculated and experimental results. Magnetite deposits were fabricated in the laboratory and were characterized using a variety of techniques. Heat transfer measurements were then taken, so that the effect of deposit parameters, including pore size distribution, porosity, permeability and thickness, as well as the effect of mass flux, heat flux and steam quality were investigated. The model predictions were consistent with the experimental results, differing by an average of ±17.5%. Over the range of parameters studied, pore size distribution dominated the deposit heat transfer. It was found that some fabricated deposits improved the heat transfer of the u-tubes, whereas others hindered it. The data were consistent with that of fouled u-tubes pulled from CANDU steam generators. The conditions of the heat transfer measurements and the fabricated deposits were similar to those of US and Canadian steam generators. Therefore, the conclusions drawn in this study are presumed to apply to the steam generators used in the Canadian and US industries."],"dc:description.degree":["Ph.D."],"dc:description.statementofresponsibility":["by Jennifer L. Uhle."],"dc:format.extent":["141 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["48181481"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/17499"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Nuclear Engineering."],"dc:title":["Boiling heat transfer characteristics of steam generator U-tube fouling"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T07:24:42Z"}