{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/31080"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/31080","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Measuring the neck transfer function of laryngectomy patients","abstract":"Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 1999.","abstract_html":"Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 1999.","abstract_has_math":false,"creators":["Meltzner, Geoffrey S. (Geoffrey Seth), 1973-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Kenneth N. Stevens and Robert E. Hillman."],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999","date_published":"1999","updated_at":"2026-11-27T04:20:04Z","subjects":["Electrical Engineering and Computer Science"],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["42678667"],"render_values":[{"text":"42678667","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/31080","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/31080","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F31080","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F31080","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kenneth N. Stevens and Robert E. Hillman."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Measurements of the Neck Transfer Function (NTF), defined as the ratio of the estimated volume velocity that excites the vocal tract to the acceleration measured at the neck wall when the neck is driven by a mini-shaker, were made at three different positions on the necks of ten laryngectomized subjects (five males and five females) and four normal laryngeal speakers (two males and two females). A mini-shaker driven by broadband noise, provided excitation to the necks of subjects as they configured their vocal tracts to mimic the production of the vowels /a/, /ae/, and I/. The sound pressure at the lips was measured with a microphone and an impedance head mounted on the shaker measured both the force and acceleration. Overall, the results indicated that the neck wall passes low frequency sounds better than high frequency sounds. A comparison of the NTFs of four subject sub-groups revealed that the NTFs of female laryngeal speakers differed from the NTFs of the other groups (male laryngeal speakers, laryngectomized males and laryngectomized females). In addition, there was a notable amount of inter-subject variability even within a subject group. The results also indicate that the NTF is relatively independent of the amount of pressure with which one applies the shaker to the neck. These results should be useful for aiding in the design of an improved neck-type electrolarynx."]},{"key":"dc:creator","label":"Author","values":["Meltzner, Geoffrey S. (Geoffrey Seth), 1973-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-02-02T18:45:53Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-02-02T18:45:53Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["1998"]},{"key":"dc:date.issued","label":"Date","values":["1999"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["42678667"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/31080"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1e2a15ea-d3d6-4855-b850-c8b1c8d0375c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Measuring the neck transfer function of laryngectomy patients</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>1999</PublicationDate> <Authors> <Author> <DisplayName>Meltzner, Geoffrey S. (Geoffrey Seth), 1973-</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> <Editor> <DisplayName>Measurements of the Neck Transfer Function (NTF), defined as the ratio of the estimated volume velocity that excites the vocal tract to the acceleration measured at the neck wall when the neck is driven by a mini-shaker, were made at three different positions on the necks of ten laryngectomized subjects (five males and five females) and four normal laryngeal speakers (two males and two females). A mini-shaker driven by broadband noise, provided excitation to the necks of subjects as they configured their vocal tracts to mimic the production of the vowels /a/, /ae/, and I/. The sound pressure at the lips was measured with a microphone and an impedance head mounted on the shaker measured both the force and acceleration. Overall, the results indicated that the neck wall passes low frequency sounds better than high frequency sounds. A comparison of the NTFs of four subject sub-groups revealed that the NTFs of female laryngeal speakers differed from the NTFs of the other groups (male laryngeal speakers, laryngectomized males and laryngectomized females). In addition, there was a notable amount of inter-subject variability even within a subject group. The results also indicate that the NTF is relatively independent of the amount of pressure with which one applies the shaker to the neck. These results should be useful for aiding in the design of an improved neck-type electrolarynx.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Editor> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science</Keyword> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 1999.","Includes bibliographical references (p. 92-93)."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Geoffrey S. Meltzner."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["93 p.","5255700 bytes","5266721 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Measuring the neck transfer function of laryngectomy patients"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1e2a15ea-d3d6-4855-b850-c8b1c8d0375c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Measuring the neck transfer function of laryngectomy patients</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>1999</PublicationDate> <Authors> <Author> <DisplayName>Meltzner, Geoffrey S. (Geoffrey Seth), 1973-</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> <Editor> <DisplayName>Measurements of the Neck Transfer Function (NTF), defined as the ratio of the estimated volume velocity that excites the vocal tract to the acceleration measured at the neck wall when the neck is driven by a mini-shaker, were made at three different positions on the necks of ten laryngectomized subjects (five males and five females) and four normal laryngeal speakers (two males and two females). A mini-shaker driven by broadband noise, provided excitation to the necks of subjects as they configured their vocal tracts to mimic the production of the vowels /a/, /ae/, and I/. The sound pressure at the lips was measured with a microphone and an impedance head mounted on the shaker measured both the force and acceleration. Overall, the results indicated that the neck wall passes low frequency sounds better than high frequency sounds. A comparison of the NTFs of four subject sub-groups revealed that the NTFs of female laryngeal speakers differed from the NTFs of the other groups (male laryngeal speakers, laryngectomized males and laryngectomized females). In addition, there was a notable amount of inter-subject variability even within a subject group. The results also indicate that the NTF is relatively independent of the amount of pressure with which one applies the shaker to the neck. These results should be useful for aiding in the design of an improved neck-type electrolarynx.</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Editor> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science</Keyword> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Kenneth N. Stevens and Robert E. Hillman."],"dc:contributor.other":["Measurements of the Neck Transfer Function (NTF), defined as the ratio of the estimated volume velocity that excites the vocal tract to the acceleration measured at the neck wall when the neck is driven by a mini-shaker, were made at three different positions on the necks of ten laryngectomized subjects (five males and five females) and four normal laryngeal speakers (two males and two females). A mini-shaker driven by broadband noise, provided excitation to the necks of subjects as they configured their vocal tracts to mimic the production of the vowels /a/, /ae/, and I/. The sound pressure at the lips was measured with a microphone and an impedance head mounted on the shaker measured both the force and acceleration. Overall, the results indicated that the neck wall passes low frequency sounds better than high frequency sounds. A comparison of the NTFs of four subject sub-groups revealed that the NTFs of female laryngeal speakers differed from the NTFs of the other groups (male laryngeal speakers, laryngectomized males and laryngectomized females). In addition, there was a notable amount of inter-subject variability even within a subject group. The results also indicate that the NTF is relatively independent of the amount of pressure with which one applies the shaker to the neck. These results should be useful for aiding in the design of an improved neck-type electrolarynx."],"dc:creator":["Meltzner, Geoffrey S. (Geoffrey Seth), 1973-"],"dc:date.accessioned":["2006-02-02T18:45:53Z"],"dc:date.available":["2006-02-02T18:45:53Z"],"dc:date.copyright":["1998"],"dc:date.issued":["1999"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 1999.","Includes bibliographical references (p. 92-93)."],"dc:description.degree":["S.M."],"dc:description.statementofresponsibility":["by Geoffrey S. Meltzner."],"dc:format.extent":["93 p.","5255700 bytes","5266721 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["42678667"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/31080"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science"],"dc:title":["Measuring the neck transfer function of laryngectomy patients"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T04:20:04Z"}