{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/32301"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/32301","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Precision measurement of the proton electric to magnetic form factor ratio with BLAST","abstract":"We have measured ... in the South Hall Ring of the MIT-Bates Linear Accelerator Facility. This experiment used a polarized electron beam, a pure hydrogen internal polarized target, and the symmetric Bates Large Acceptance Spectrometer Toroid (BLAST) detector. By measuring the spin-dependent elastic ... asymmetry in both sectors simultaneously, we could extract the form factor ratio independent of beam and target polarization. This was the first experiment to measure ... using a polarized target, which is complementary to recoil polarimetry experiments.","abstract_html":"We have measured ... in the South Hall Ring of the MIT-Bates Linear Accelerator Facility. This experiment used a polarized electron beam, a pure hydrogen internal polarized target, and the symmetric Bates Large Acceptance Spectrometer Toroid (BLAST) detector. By measuring the spin-dependent elastic ... asymmetry in both sectors simultaneously, we could extract the form factor ratio independent of beam and target polarization. This was the first experiment to measure ... using a polarized target, which is complementary to recoil polarimetry experiments.","abstract_has_math":false,"creators":["Crawford, Christopher Blair"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Haiyan Gao."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-29T16:51:30Z","subjects":["Physics."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["61347184"],"render_values":[{"text":"61347184","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/32301","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/32301","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F32301","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F32301","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Haiyan Gao."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:creator","label":"Author","values":["Crawford, Christopher Blair"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-03-29T18:32:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-03-29T18:32:08Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2005"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["61347184"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/32301"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"825160fc-db0b-4c60-a299-2da59030d342\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Precision measurement of the proton electric to magnetic form factor ratio with BLAST</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Crawford, Christopher Blair</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>We have measured ... in the South Hall Ring of the MIT-Bates Linear Accelerator Facility. This experiment used a polarized electron beam, a pure hydrogen internal polarized target, and the symmetric Bates Large Acceptance Spectrometer Toroid (BLAST) detector. By measuring the spin-dependent elastic ... asymmetry in both sectors simultaneously, we could extract the form factor ratio independent of beam and target polarization. This was the first experiment to measure ... using a polarized target, which is complementary to recoil polarimetry experiments.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Physics, 2005.","Includes bibliographical references (p. 185-195)."]},{"key":"dc:description.abstract","label":"Abstract","values":["We have measured ... in the South Hall Ring of the MIT-Bates Linear Accelerator Facility. This experiment used a polarized electron beam, a pure hydrogen internal polarized target, and the symmetric Bates Large Acceptance Spectrometer Toroid (BLAST) detector. By measuring the spin-dependent elastic ... asymmetry in both sectors simultaneously, we could extract the form factor ratio independent of beam and target polarization. This was the first experiment to measure ... using a polarized target, which is complementary to recoil polarimetry experiments."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Christopher Blair Crawford."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["195 p.","11532216 bytes","11544037 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Precision measurement of the proton electric to magnetic form factor ratio with BLAST"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"825160fc-db0b-4c60-a299-2da59030d342\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Precision measurement of the proton electric to magnetic form factor ratio with BLAST</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Crawford, Christopher Blair</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>We have measured ... in the South Hall Ring of the MIT-Bates Linear Accelerator Facility. This experiment used a polarized electron beam, a pure hydrogen internal polarized target, and the symmetric Bates Large Acceptance Spectrometer Toroid (BLAST) detector. By measuring the spin-dependent elastic ... asymmetry in both sectors simultaneously, we could extract the form factor ratio independent of beam and target polarization. This was the first experiment to measure ... using a polarized target, which is complementary to recoil polarimetry experiments.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Haiyan Gao."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:creator":["Crawford, Christopher Blair"],"dc:date.accessioned":["2006-03-29T18:32:08Z"],"dc:date.available":["2006-03-29T18:32:08Z"],"dc:date.copyright":["2005"],"dc:date.issued":["2005"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Physics, 2005.","Includes bibliographical references (p. 185-195)."],"dc:description.abstract":["We have measured ... in the South Hall Ring of the MIT-Bates Linear Accelerator Facility. This experiment used a polarized electron beam, a pure hydrogen internal polarized target, and the symmetric Bates Large Acceptance Spectrometer Toroid (BLAST) detector. By measuring the spin-dependent elastic ... asymmetry in both sectors simultaneously, we could extract the form factor ratio independent of beam and target polarization. This was the first experiment to measure ... using a polarized target, which is complementary to recoil polarimetry experiments."],"dc:description.degree":["Ph.D."],"dc:description.statementofresponsibility":["by Christopher Blair Crawford."],"dc:format.extent":["195 p.","11532216 bytes","11544037 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["61347184"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/32301"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Precision measurement of the proton electric to magnetic form factor ratio with BLAST"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-29T16:51:30Z"}