{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/32936"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/32936","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Characterization and optimization of PDMS microfluidic devices for rapid DNA hybridization","abstract":"Two elastomeric microfluidic devices were designed for the purpose of conducting rapid, flow-based, multiplexed DNA hybridization. Experimental results showed that flowing hybridization assays could detect similar concentrations of labeled probe as standard stationary microarrays, but in 1/100h of the time, using 2% of the sample volume. An 8-channel device was used to spot glass slides with 64 hybridization assays and generate data supporting a theoretical model of DNA hybridization in both traditional stationary microarrays and flowing sample arrays. Larger devices were also used to create rrays of 96x96 spots on a single slide, demonstrating the scalability of the technology. Protocols were written and optimized for the use of both chips, allowing the technology to be distributed to collaborating labs for further development.","abstract_html":"Two elastomeric microfluidic devices were designed for the purpose of conducting rapid, flow-based, multiplexed DNA hybridization. Experimental results showed that flowing hybridization assays could detect similar concentrations of labeled probe as standard stationary microarrays, but in 1/100h of the time, using 2% of the sample volume. An 8-channel device was used to spot glass slides with 64 hybridization assays and generate data supporting a theoretical model of DNA hybridization in both traditional stationary microarrays and flowing sample arrays. Larger devices were also used to create rrays of 96x96 spots on a single slide, demonstrating the scalability of the technology. Protocols were written and optimized for the use of both chips, allowing the technology to be distributed to collaborating labs for further development.","abstract_has_math":false,"creators":["Hu, Jenny (Jenny Ezu)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Todd Thorsen."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-27T04:19:40Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["62783474"],"render_values":[{"text":"62783474","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/32936","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/32936","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F32936","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F32936","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Todd Thorsen."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Hu, Jenny (Jenny Ezu)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-05-15T20:40:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-05-15T20:40:26Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2005"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["62783474"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/32936"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"19c28266-5c8c-4e90-b330-cf3d90788a28\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Characterization and optimization of PDMS microfluidic devices for rapid DNA hybridization</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Hu, Jenny (Jenny Ezu)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Two elastomeric microfluidic devices were designed for the purpose of conducting rapid, flow-based, multiplexed DNA hybridization. Experimental results showed that flowing hybridization assays could detect similar concentrations of labeled probe as standard stationary microarrays, but in 1/100h of the time, using 2% of the sample volume. An 8-channel device was used to spot glass slides with 64 hybridization assays and generate data supporting a theoretical model of DNA hybridization in both traditional stationary microarrays and flowing sample arrays. Larger devices were also used to create rrays of 96x96 spots on a single slide, demonstrating the scalability of the technology. Protocols were written and optimized for the use of both chips, allowing the technology to be distributed to collaborating labs for further development.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.","Includes bibliographical references (p. 51-53)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Two elastomeric microfluidic devices were designed for the purpose of conducting rapid, flow-based, multiplexed DNA hybridization. Experimental results showed that flowing hybridization assays could detect similar concentrations of labeled probe as standard stationary microarrays, but in 1/100h of the time, using 2% of the sample volume. An 8-channel device was used to spot glass slides with 64 hybridization assays and generate data supporting a theoretical model of DNA hybridization in both traditional stationary microarrays and flowing sample arrays. Larger devices were also used to create rrays of 96x96 spots on a single slide, demonstrating the scalability of the technology. Protocols were written and optimized for the use of both chips, allowing the technology to be distributed to collaborating labs for further development."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Jenny Hu."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["60 p.","3815537 bytes","3817203 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization and optimization of PDMS microfluidic devices for rapid DNA hybridization"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"19c28266-5c8c-4e90-b330-cf3d90788a28\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Characterization and optimization of PDMS microfluidic devices for rapid DNA hybridization</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Hu, Jenny (Jenny Ezu)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Two elastomeric microfluidic devices were designed for the purpose of conducting rapid, flow-based, multiplexed DNA hybridization. Experimental results showed that flowing hybridization assays could detect similar concentrations of labeled probe as standard stationary microarrays, but in 1/100h of the time, using 2% of the sample volume. An 8-channel device was used to spot glass slides with 64 hybridization assays and generate data supporting a theoretical model of DNA hybridization in both traditional stationary microarrays and flowing sample arrays. Larger devices were also used to create rrays of 96x96 spots on a single slide, demonstrating the scalability of the technology. Protocols were written and optimized for the use of both chips, allowing the technology to be distributed to collaborating labs for further development.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Todd Thorsen."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Hu, Jenny (Jenny Ezu)"],"dc:date.accessioned":["2006-05-15T20:40:26Z"],"dc:date.available":["2006-05-15T20:40:26Z"],"dc:date.copyright":["2005"],"dc:date.issued":["2005"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2005.","Includes bibliographical references (p. 51-53)."],"dc:description.abstract":["Two elastomeric microfluidic devices were designed for the purpose of conducting rapid, flow-based, multiplexed DNA hybridization. Experimental results showed that flowing hybridization assays could detect similar concentrations of labeled probe as standard stationary microarrays, but in 1/100h of the time, using 2% of the sample volume. An 8-channel device was used to spot glass slides with 64 hybridization assays and generate data supporting a theoretical model of DNA hybridization in both traditional stationary microarrays and flowing sample arrays. Larger devices were also used to create rrays of 96x96 spots on a single slide, demonstrating the scalability of the technology. Protocols were written and optimized for the use of both chips, allowing the technology to be distributed to collaborating labs for further development."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Jenny Hu."],"dc:format.extent":["60 p.","3815537 bytes","3817203 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["62783474"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/32936"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Characterization and optimization of PDMS microfluidic devices for rapid DNA hybridization"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T04:19:40Z"}