{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/34142"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/34142","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Approaches to optimal inertial instrument calibration using slewing","abstract":"Calibration of an inertial measurement unit is important to the success of accuracy-sensitive missions. This thesis analyzes calibration techniques for two inertial measurement mechanizations: (1) an inertially stabilized system and (2) an inertially referenced slew. An inertially referenced slew rotates the inertial measurement unit with respect to an inertial reference frame independent of the vehicle motion. The appropriate inertially referenced slew is determined by a proposed optimal calibration method that maximizes the correlation between a measurement and a covector, specifying a mission performance index. The performances of a six-position dwell calibration (inertially stabilized system) and an optimal slewing calibration (inertially referenced slew) are determined to be dependent on the mission. The inertially stabilized system is preferred for determining accelerometer errors and an inertially referenced slew is preferred for calibrating rate-sensitive gyroscope errors.","abstract_html":"Calibration of an inertial measurement unit is important to the success of accuracy-sensitive missions. This thesis analyzes calibration techniques for two inertial measurement mechanizations: (1) an inertially stabilized system and (2) an inertially referenced slew. An inertially referenced slew rotates the inertial measurement unit with respect to an inertial reference frame independent of the vehicle motion. The appropriate inertially referenced slew is determined by a proposed optimal calibration method that maximizes the correlation between a measurement and a covector, specifying a mission performance index. The performances of a six-position dwell calibration (inertially stabilized system) and an optimal slewing calibration (inertially referenced slew) are determined to be dependent on the mission. The inertially stabilized system is preferred for determining accelerometer errors and an inertially referenced slew is preferred for calibrating rate-sensitive gyroscope errors.","abstract_has_math":false,"creators":["Becker, Theresia Caezilia"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Matthew Bottkol and George Schmidt."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-29T16:53:11Z","subjects":["Aeronautics and Astronautics."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["67837333"],"render_values":[{"text":"67837333","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/34142","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/34142","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F34142","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F34142","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Matthew Bottkol and George Schmidt."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."]},{"key":"dc:creator","label":"Author","values":["Becker, Theresia Caezilia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2006-09-28T15:10:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2006-09-28T15:10:59Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2005"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Aeronautics and Astronautics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["67837333"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/34142"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"92ebe336-aa5a-44f8-a791-1cfeb9fa0733\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Approaches to optimal inertial instrument calibration using slewing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Becker, Theresia Caezilia</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Aeronautics and Astronautics.</Keyword> <Abstract>Calibration of an inertial measurement unit is important to the success of accuracy-sensitive missions. This thesis analyzes calibration techniques for two inertial measurement mechanizations: (1) an inertially stabilized system and (2) an inertially referenced slew. An inertially referenced slew rotates the inertial measurement unit with respect to an inertial reference frame independent of the vehicle motion. The appropriate inertially referenced slew is determined by a proposed optimal calibration method that maximizes the correlation between a measurement and a covector, specifying a mission performance index. The performances of a six-position dwell calibration (inertially stabilized system) and an optimal slewing calibration (inertially referenced slew) are determined to be dependent on the mission. The inertially stabilized system is preferred for determining accelerometer errors and an inertially referenced slew is preferred for calibrating rate-sensitive gyroscope errors.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2005.","Includes bibliographical references (p. 61)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Calibration of an inertial measurement unit is important to the success of accuracy-sensitive missions. This thesis analyzes calibration techniques for two inertial measurement mechanizations: (1) an inertially stabilized system and (2) an inertially referenced slew. An inertially referenced slew rotates the inertial measurement unit with respect to an inertial reference frame independent of the vehicle motion. The appropriate inertially referenced slew is determined by a proposed optimal calibration method that maximizes the correlation between a measurement and a covector, specifying a mission performance index. The performances of a six-position dwell calibration (inertially stabilized system) and an optimal slewing calibration (inertially referenced slew) are determined to be dependent on the mission. The inertially stabilized system is preferred for determining accelerometer errors and an inertially referenced slew is preferred for calibrating rate-sensitive gyroscope errors."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Theresia C. Becker."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["61 p.","2209459 bytes","2211915 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Approaches to optimal inertial instrument calibration using slewing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"92ebe336-aa5a-44f8-a791-1cfeb9fa0733\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Approaches to optimal inertial instrument calibration using slewing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Becker, Theresia Caezilia</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Aeronautics and Astronautics.</Keyword> <Abstract>Calibration of an inertial measurement unit is important to the success of accuracy-sensitive missions. This thesis analyzes calibration techniques for two inertial measurement mechanizations: (1) an inertially stabilized system and (2) an inertially referenced slew. An inertially referenced slew rotates the inertial measurement unit with respect to an inertial reference frame independent of the vehicle motion. The appropriate inertially referenced slew is determined by a proposed optimal calibration method that maximizes the correlation between a measurement and a covector, specifying a mission performance index. The performances of a six-position dwell calibration (inertially stabilized system) and an optimal slewing calibration (inertially referenced slew) are determined to be dependent on the mission. The inertially stabilized system is preferred for determining accelerometer errors and an inertially referenced slew is preferred for calibrating rate-sensitive gyroscope errors.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Matthew Bottkol and George Schmidt."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Aeronautics and Astronautics."],"dc:creator":["Becker, Theresia Caezilia"],"dc:date.accessioned":["2006-09-28T15:10:59Z"],"dc:date.available":["2006-09-28T15:10:59Z"],"dc:date.copyright":["2005"],"dc:date.issued":["2005"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Aeronautics and Astronautics, 2005.","Includes bibliographical references (p. 61)."],"dc:description.abstract":["Calibration of an inertial measurement unit is important to the success of accuracy-sensitive missions. This thesis analyzes calibration techniques for two inertial measurement mechanizations: (1) an inertially stabilized system and (2) an inertially referenced slew. An inertially referenced slew rotates the inertial measurement unit with respect to an inertial reference frame independent of the vehicle motion. The appropriate inertially referenced slew is determined by a proposed optimal calibration method that maximizes the correlation between a measurement and a covector, specifying a mission performance index. The performances of a six-position dwell calibration (inertially stabilized system) and an optimal slewing calibration (inertially referenced slew) are determined to be dependent on the mission. The inertially stabilized system is preferred for determining accelerometer errors and an inertially referenced slew is preferred for calibrating rate-sensitive gyroscope errors."],"dc:description.degree":["S.M."],"dc:description.statementofresponsibility":["by Theresia C. Becker."],"dc:format.extent":["61 p.","2209459 bytes","2211915 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["67837333"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/34142"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Aeronautics and Astronautics."],"dc:title":["Approaches to optimal inertial instrument calibration using slewing"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-29T16:53:11Z"}