{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/36129"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/36129","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Ultraviolet laser calibration of drift chambers","abstract":"We demonstrate the use of a focused ultraviolet laser as a track calibration source in drift chambers, and specifically in a small time projection chamber (TPC). Drift chambers such as TPCs reconstruct the trajectories of charged particles by amplifying and collecting electrons produced by ionization of gas atoms with which the target particle collides. The ultraviolet laser induces a two-photon ionization of gaseous organic compounds along the beam, providing an artificially produced track which may then be used as a calibration source, particularly because it behaves as a particle of infinite momentum whose trajectory is straight in a magnetic field. To this end, we present measurements of the ionization profile of the laser for various gasses and model this ionization in terms of photon flux.","abstract_html":"We demonstrate the use of a focused ultraviolet laser as a track calibration source in drift chambers, and specifically in a small time projection chamber (TPC). Drift chambers such as TPCs reconstruct the trajectories of charged particles by amplifying and collecting electrons produced by ionization of gas atoms with which the target particle collides. The ultraviolet laser induces a two-photon ionization of gaseous organic compounds along the beam, providing an artificially produced track which may then be used as a calibration source, particularly because it behaves as a particle of infinite momentum whose trajectory is straight in a magnetic field. To this end, we present measurements of the ionization profile of the laser for various gasses and model this ionization in terms of photon flux.","abstract_has_math":false,"creators":["Elliott, Grant (Grant Andrew)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ulrich J. Becker."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-11-27T23:31:10Z","subjects":["Physics."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["72471760"],"render_values":[{"text":"72471760","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/36129","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/36129","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F36129","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F36129","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ulrich J. Becker."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:creator","label":"Author","values":["Elliott, Grant (Grant Andrew)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-02-21T11:35:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-02-21T11:35:34Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2006"]},{"key":"dc:date.issued","label":"Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["72471760"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/36129"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4f3f39b1-e427-4300-8a3e-1373e5ac69bd\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Ultraviolet laser calibration of drift chambers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2006</PublicationDate> <Authors> <Author> <DisplayName>Elliott, Grant (Grant Andrew)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>We demonstrate the use of a focused ultraviolet laser as a track calibration source in drift chambers, and specifically in a small time projection chamber (TPC). Drift chambers such as TPCs reconstruct the trajectories of charged particles by amplifying and collecting electrons produced by ionization of gas atoms with which the target particle collides. The ultraviolet laser induces a two-photon ionization of gaseous organic compounds along the beam, providing an artificially produced track which may then be used as a calibration source, particularly because it behaves as a particle of infinite momentum whose trajectory is straight in a magnetic field. To this end, we present measurements of the ionization profile of the laser for various gasses and model this ionization in terms of photon flux.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2006.","Includes bibliographical references (p. 55-56)."]},{"key":"dc:description.abstract","label":"Abstract","values":["We demonstrate the use of a focused ultraviolet laser as a track calibration source in drift chambers, and specifically in a small time projection chamber (TPC). Drift chambers such as TPCs reconstruct the trajectories of charged particles by amplifying and collecting electrons produced by ionization of gas atoms with which the target particle collides. The ultraviolet laser induces a two-photon ionization of gaseous organic compounds along the beam, providing an artificially produced track which may then be used as a calibration source, particularly because it behaves as a particle of infinite momentum whose trajectory is straight in a magnetic field. To this end, we present measurements of the ionization profile of the laser for various gasses and model this ionization in terms of photon flux."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Grant Elliott."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["56 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Ultraviolet laser calibration of drift chambers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4f3f39b1-e427-4300-8a3e-1373e5ac69bd\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Ultraviolet laser calibration of drift chambers</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2006</PublicationDate> <Authors> <Author> <DisplayName>Elliott, Grant (Grant Andrew)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>We demonstrate the use of a focused ultraviolet laser as a track calibration source in drift chambers, and specifically in a small time projection chamber (TPC). Drift chambers such as TPCs reconstruct the trajectories of charged particles by amplifying and collecting electrons produced by ionization of gas atoms with which the target particle collides. The ultraviolet laser induces a two-photon ionization of gaseous organic compounds along the beam, providing an artificially produced track which may then be used as a calibration source, particularly because it behaves as a particle of infinite momentum whose trajectory is straight in a magnetic field. To this end, we present measurements of the ionization profile of the laser for various gasses and model this ionization in terms of photon flux.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Ulrich J. Becker."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:creator":["Elliott, Grant (Grant Andrew)"],"dc:date.accessioned":["2007-02-21T11:35:34Z"],"dc:date.available":["2007-02-21T11:35:34Z"],"dc:date.copyright":["2006"],"dc:date.issued":["2006"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2006.","Includes bibliographical references (p. 55-56)."],"dc:description.abstract":["We demonstrate the use of a focused ultraviolet laser as a track calibration source in drift chambers, and specifically in a small time projection chamber (TPC). Drift chambers such as TPCs reconstruct the trajectories of charged particles by amplifying and collecting electrons produced by ionization of gas atoms with which the target particle collides. The ultraviolet laser induces a two-photon ionization of gaseous organic compounds along the beam, providing an artificially produced track which may then be used as a calibration source, particularly because it behaves as a particle of infinite momentum whose trajectory is straight in a magnetic field. To this end, we present measurements of the ionization profile of the laser for various gasses and model this ionization in terms of photon flux."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Grant Elliott."],"dc:format.extent":["56 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["72471760"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/36129"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Ultraviolet laser calibration of drift chambers"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T23:31:10Z"}