{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/36714"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/36714","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Portable sensor to measure the mechanical compliance transfer function of a material","abstract":"A device that can measure the dynamic compliance of a material has applications for research, health sciences and for use as a pedagogical tool. A device was created which stochastically perturbs a material while measuring the resulting forces and displacements. A software program then creates a non-parameterized impulse response function in addition to a fit second order model for the material. The device was tested on a compliant sponge sample which exhibited highly nonlinear dynamic behavior. The low frequency compliance of the sponge was measured with the device with 16% to 31% error. Improvements for further dynamic testing on the sponge are presented as well as future improvements to the design of the device.","abstract_html":"A device that can measure the dynamic compliance of a material has applications for research, health sciences and for use as a pedagogical tool. A device was created which stochastically perturbs a material while measuring the resulting forces and displacements. A software program then creates a non-parameterized impulse response function in addition to a fit second order model for the material. The device was tested on a compliant sponge sample which exhibited highly nonlinear dynamic behavior. The low frequency compliance of the sponge was measured with the device with 16% to 31% error. Improvements for further dynamic testing on the sponge are presented as well as future improvements to the design of the device.","abstract_has_math":false,"creators":["Post, Ethan A. (Ethan Adam)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Ian W. Hunter."],"committee_chairs":[],"committee_members":[],"year":2006,"date_issued":"2006","date_published":"2006","updated_at":"2026-11-27T23:30:55Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["77561330"],"render_values":[{"text":"77561330","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/36714","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/36714","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F36714","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F36714","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ian W. Hunter."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Post, Ethan A. (Ethan Adam)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-03-12T17:46:58Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-03-12T17:46:58Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2006"]},{"key":"dc:date.issued","label":"Date","values":["2006"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["77561330"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/36714"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4e12a476-abed-4f88-b5cd-c10d140b9d63\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Portable sensor to measure the mechanical compliance transfer function of a material</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2006</PublicationDate> <Authors> <Author> <DisplayName>Post, Ethan A. (Ethan Adam)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>A device that can measure the dynamic compliance of a material has applications for research, health sciences and for use as a pedagogical tool. A device was created which stochastically perturbs a material while measuring the resulting forces and displacements. A software program then creates a non-parameterized impulse response function in addition to a fit second order model for the material. The device was tested on a compliant sponge sample which exhibited highly nonlinear dynamic behavior. The low frequency compliance of the sponge was measured with the device with 16% to 31% error. Improvements for further dynamic testing on the sponge are presented as well as future improvements to the design of the device.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.","Includes bibliographical references (leaves 35-36)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A device that can measure the dynamic compliance of a material has applications for research, health sciences and for use as a pedagogical tool. A device was created which stochastically perturbs a material while measuring the resulting forces and displacements. A software program then creates a non-parameterized impulse response function in addition to a fit second order model for the material. The device was tested on a compliant sponge sample which exhibited highly nonlinear dynamic behavior. The low frequency compliance of the sponge was measured with the device with 16% to 31% error. Improvements for further dynamic testing on the sponge are presented as well as future improvements to the design of the device."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Ethan A. Post."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["49 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Portable sensor to measure the mechanical compliance transfer function of a material"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4e12a476-abed-4f88-b5cd-c10d140b9d63\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Portable sensor to measure the mechanical compliance transfer function of a material</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2006</PublicationDate> <Authors> <Author> <DisplayName>Post, Ethan A. (Ethan Adam)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>A device that can measure the dynamic compliance of a material has applications for research, health sciences and for use as a pedagogical tool. A device was created which stochastically perturbs a material while measuring the resulting forces and displacements. A software program then creates a non-parameterized impulse response function in addition to a fit second order model for the material. The device was tested on a compliant sponge sample which exhibited highly nonlinear dynamic behavior. The low frequency compliance of the sponge was measured with the device with 16% to 31% error. Improvements for further dynamic testing on the sponge are presented as well as future improvements to the design of the device.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Ian W. Hunter."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Post, Ethan A. (Ethan Adam)"],"dc:date.accessioned":["2007-03-12T17:46:58Z"],"dc:date.available":["2007-03-12T17:46:58Z"],"dc:date.copyright":["2006"],"dc:date.issued":["2006"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2006.","Includes bibliographical references (leaves 35-36)."],"dc:description.abstract":["A device that can measure the dynamic compliance of a material has applications for research, health sciences and for use as a pedagogical tool. A device was created which stochastically perturbs a material while measuring the resulting forces and displacements. A software program then creates a non-parameterized impulse response function in addition to a fit second order model for the material. The device was tested on a compliant sponge sample which exhibited highly nonlinear dynamic behavior. The low frequency compliance of the sponge was measured with the device with 16% to 31% error. Improvements for further dynamic testing on the sponge are presented as well as future improvements to the design of the device."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Ethan A. Post."],"dc:format.extent":["49 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["77561330"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/36714"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Portable sensor to measure the mechanical compliance transfer function of a material"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T23:30:55Z"}