{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/36758"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/36758","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A combined microfluidic/dielectrophoretic microorganism concentrator","abstract":"This thesis presents the development of a high-throughput microfluidic microorganism concentrator for pathogen detection applications. Interdigitated electrodes lining the bottom of the channel use positive dielectrophoretic forces to trap particles. A passive mixer is used to circulate the liquid in the channel, transporting particles to within the trapping region of the electrodes. Samples are extracted and their concentrations measured using a spectrophotometer. Concentration enhancements up to 40x at 500 gl/min flowrate using polystyrene microspheres and up to 10x at 100 gll/min flowrate using B. subtilis spores are achieved.","abstract_html":"This thesis presents the development of a high-throughput microfluidic microorganism concentrator for pathogen detection applications. Interdigitated electrodes lining the bottom of the channel use positive dielectrophoretic forces to trap particles. A passive mixer is used to circulate the liquid in the channel, transporting particles to within the trapping region of the electrodes. Samples are extracted and their concentrations measured using a spectrophotometer. Concentration enhancements up to 40x at 500 gl/min flowrate using polystyrene microspheres and up to 10x at 100 gll/min flowrate using B. subtilis spores are achieved.","abstract_has_math":false,"creators":["Gadish, Nitzan"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Joel Voldman."],"committee_chairs":[],"committee_members":[],"year":2005,"date_issued":"2005","date_published":"2005","updated_at":"2026-11-27T04:19:45Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["78616940"],"render_values":[{"text":"78616940","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/36758","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/36758","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F36758","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F36758","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Joel Voldman."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Gadish, Nitzan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2007-03-12T17:51:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2007-03-12T17:51:03Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2005"]},{"key":"dc:date.issued","label":"Date","values":["2005"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["78616940"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/36758"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1a500cd6-7e1d-45af-8a0d-adeed138d069\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>A combined microfluidic/dielectrophoretic microorganism concentrator</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Gadish, Nitzan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>This thesis presents the development of a high-throughput microfluidic microorganism concentrator for pathogen detection applications. Interdigitated electrodes lining the bottom of the channel use positive dielectrophoretic forces to trap particles. A passive mixer is used to circulate the liquid in the channel, transporting particles to within the trapping region of the electrodes. Samples are extracted and their concentrations measured using a spectrophotometer. Concentration enhancements up to 40x at 500 gl/min flowrate using polystyrene microspheres and up to 10x at 100 gll/min flowrate using B. subtilis spores are achieved.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.","Includes bibliographical references (p. 71-72)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents the development of a high-throughput microfluidic microorganism concentrator for pathogen detection applications. Interdigitated electrodes lining the bottom of the channel use positive dielectrophoretic forces to trap particles. A passive mixer is used to circulate the liquid in the channel, transporting particles to within the trapping region of the electrodes. Samples are extracted and their concentrations measured using a spectrophotometer. Concentration enhancements up to 40x at 500 gl/min flowrate using polystyrene microspheres and up to 10x at 100 gll/min flowrate using B. subtilis spores are achieved."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Nitzan Gadish."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["72 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A combined microfluidic/dielectrophoretic microorganism concentrator"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1a500cd6-7e1d-45af-8a0d-adeed138d069\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>A combined microfluidic/dielectrophoretic microorganism concentrator</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2005</PublicationDate> <Authors> <Author> <DisplayName>Gadish, Nitzan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>This thesis presents the development of a high-throughput microfluidic microorganism concentrator for pathogen detection applications. Interdigitated electrodes lining the bottom of the channel use positive dielectrophoretic forces to trap particles. A passive mixer is used to circulate the liquid in the channel, transporting particles to within the trapping region of the electrodes. Samples are extracted and their concentrations measured using a spectrophotometer. Concentration enhancements up to 40x at 500 gl/min flowrate using polystyrene microspheres and up to 10x at 100 gll/min flowrate using B. subtilis spores are achieved.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Joel Voldman."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Gadish, Nitzan"],"dc:date.accessioned":["2007-03-12T17:51:03Z"],"dc:date.available":["2007-03-12T17:51:03Z"],"dc:date.copyright":["2005"],"dc:date.issued":["2005"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2005.","Includes bibliographical references (p. 71-72)."],"dc:description.abstract":["This thesis presents the development of a high-throughput microfluidic microorganism concentrator for pathogen detection applications. Interdigitated electrodes lining the bottom of the channel use positive dielectrophoretic forces to trap particles. A passive mixer is used to circulate the liquid in the channel, transporting particles to within the trapping region of the electrodes. Samples are extracted and their concentrations measured using a spectrophotometer. Concentration enhancements up to 40x at 500 gl/min flowrate using polystyrene microspheres and up to 10x at 100 gll/min flowrate using B. subtilis spores are achieved."],"dc:description.degree":["M.Eng."],"dc:description.statementofresponsibility":["by Nitzan Gadish."],"dc:format.extent":["72 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["78616940"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/36758"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["A combined microfluidic/dielectrophoretic microorganism concentrator"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T04:19:45Z"}