{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/42299"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/42299","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Extending imaging depth of multiphoton microscopy","abstract":"Two-photon excitation fluorescence microscopy has capability of deep tissue imaging with biological samples. However, because of the inhomogeneity of the refractive index in biological samples, the wavefront of the excitation light is often distorted. Due to the distortion of the wavefront, the point spread function at the focal point becomes broadened resulting in degraded resolution and lower signal. With an adaptive optics system, which consists of a wavefront camera and deformable mirror, the wavefront distortion can be measured and corrected. By correcting the distorted wavefront with adaptive optics, resolution and signal level can be preserved at greater imaging depth.","abstract_html":"Two-photon excitation fluorescence microscopy has capability of deep tissue imaging with biological samples. However, because of the inhomogeneity of the refractive index in biological samples, the wavefront of the excitation light is often distorted. Due to the distortion of the wavefront, the point spread function at the focal point becomes broadened resulting in degraded resolution and lower signal. With an adaptive optics system, which consists of a wavefront camera and deformable mirror, the wavefront distortion can be measured and corrected. By correcting the distorted wavefront with adaptive optics, resolution and signal level can be preserved at greater imaging depth.","abstract_has_math":false,"creators":["Cha, Jae Won"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Peter T.C. So."],"committee_chairs":[],"committee_members":[],"year":2007,"date_issued":"2007","date_published":"2007","updated_at":"2026-11-27T04:19:53Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["232359016"],"render_values":[{"text":"232359016","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/42299","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/42299","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F42299","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F42299","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peter T.C. So."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Cha, Jae Won"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2008-09-03T15:16:14Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2008-09-03T15:16:14Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2007"]},{"key":"dc:date.issued","label":"Date","values":["2007"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["232359016"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/42299"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1be8650a-a393-4490-9f54-e2496d29d40e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Extending imaging depth of multiphoton microscopy</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2007</PublicationDate> <Authors> <Author> <DisplayName>Cha, Jae Won</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Two-photon excitation fluorescence microscopy has capability of deep tissue imaging with biological samples. However, because of the inhomogeneity of the refractive index in biological samples, the wavefront of the excitation light is often distorted. Due to the distortion of the wavefront, the point spread function at the focal point becomes broadened resulting in degraded resolution and lower signal. With an adaptive optics system, which consists of a wavefront camera and deformable mirror, the wavefront distortion can be measured and corrected. By correcting the distorted wavefront with adaptive optics, resolution and signal level can be preserved at greater imaging depth.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.","Includes bibliographical references (leaves 45-46)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Two-photon excitation fluorescence microscopy has capability of deep tissue imaging with biological samples. However, because of the inhomogeneity of the refractive index in biological samples, the wavefront of the excitation light is often distorted. Due to the distortion of the wavefront, the point spread function at the focal point becomes broadened resulting in degraded resolution and lower signal. With an adaptive optics system, which consists of a wavefront camera and deformable mirror, the wavefront distortion can be measured and corrected. By correcting the distorted wavefront with adaptive optics, resolution and signal level can be preserved at greater imaging depth."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Jae Won Cha."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["49 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Extending imaging depth of multiphoton microscopy"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"1be8650a-a393-4490-9f54-e2496d29d40e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Extending imaging depth of multiphoton microscopy</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2007</PublicationDate> <Authors> <Author> <DisplayName>Cha, Jae Won</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Two-photon excitation fluorescence microscopy has capability of deep tissue imaging with biological samples. However, because of the inhomogeneity of the refractive index in biological samples, the wavefront of the excitation light is often distorted. Due to the distortion of the wavefront, the point spread function at the focal point becomes broadened resulting in degraded resolution and lower signal. With an adaptive optics system, which consists of a wavefront camera and deformable mirror, the wavefront distortion can be measured and corrected. By correcting the distorted wavefront with adaptive optics, resolution and signal level can be preserved at greater imaging depth.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Peter T.C. So."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Cha, Jae Won"],"dc:date.accessioned":["2008-09-03T15:16:14Z"],"dc:date.available":["2008-09-03T15:16:14Z"],"dc:date.copyright":["2007"],"dc:date.issued":["2007"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2007.","Includes bibliographical references (leaves 45-46)."],"dc:description.abstract":["Two-photon excitation fluorescence microscopy has capability of deep tissue imaging with biological samples. However, because of the inhomogeneity of the refractive index in biological samples, the wavefront of the excitation light is often distorted. Due to the distortion of the wavefront, the point spread function at the focal point becomes broadened resulting in degraded resolution and lower signal. With an adaptive optics system, which consists of a wavefront camera and deformable mirror, the wavefront distortion can be measured and corrected. By correcting the distorted wavefront with adaptive optics, resolution and signal level can be preserved at greater imaging depth."],"dc:description.degree":["S.M."],"dc:description.statementofresponsibility":["by Jae Won Cha."],"dc:format.extent":["49 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["232359016"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/42299"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Extending imaging depth of multiphoton microscopy"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T04:19:53Z"}