{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/44465"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/44465","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Particle detector optimization via particle flow algorithms","abstract":"Using the the SLIC simulator software and the org.lcsim reconstruction framework package, the performance of Mat Charles' NonTrivialPfa.java PFA for several different detector variations was found by determining the mass resolution for a given detector geometry. The variations tested included the layering of the hadronic calorimeter, the radius of the calorimeter, the interaction material utilized in the hadronic calorimeter and the type of read-out used in the calorimeter. Based on the performance of the PFA for the different variations, the optimal detector specifications for use with the PFA were discovered. The optimal detector was found to use scintillator as the sensitive layer and steel as the interaction material in the hadronic calorimeter. A general trend in increased performance with more layering was also observed for the calorimeter. Also illuminated in the study was the discovery of unexpected performance for radius variations.","abstract_html":"Using the the SLIC simulator software and the org.lcsim reconstruction framework package, the performance of Mat Charles&#x27; NonTrivialPfa.java PFA for several different detector variations was found by determining the mass resolution for a given detector geometry. The variations tested included the layering of the hadronic calorimeter, the radius of the calorimeter, the interaction material utilized in the hadronic calorimeter and the type of read-out used in the calorimeter. Based on the performance of the PFA for the different variations, the optimal detector specifications for use with the PFA were discovered. The optimal detector was found to use scintillator as the sensitive layer and steel as the interaction material in the hadronic calorimeter. A general trend in increased performance with more layering was also observed for the calorimeter. Also illuminated in the study was the discovery of unexpected performance for radius variations.","abstract_has_math":false,"creators":["Bronk, Lawrence Fernando"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Peter Fisher."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-27T06:22:39Z","subjects":["Physics."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["297176638"],"render_values":[{"text":"297176638","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/44465","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/44465","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F44465","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F44465","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Peter Fisher."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:creator","label":"Author","values":["Bronk, Lawrence Fernando"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-01-30T16:49:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-01-30T16:49:39Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2008"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["297176638"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/44465"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2ffe6b76-6406-44e9-a6da-5fbed2055315\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Particle detector optimization via particle flow algorithms</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Bronk, Lawrence Fernando</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>Using the the SLIC simulator software and the org.lcsim reconstruction framework package, the performance of Mat Charles' NonTrivialPfa.java PFA for several different detector variations was found by determining the mass resolution for a given detector geometry. The variations tested included the layering of the hadronic calorimeter, the radius of the calorimeter, the interaction material utilized in the hadronic calorimeter and the type of read-out used in the calorimeter. Based on the performance of the PFA for the different variations, the optimal detector specifications for use with the PFA were discovered. The optimal detector was found to use scintillator as the sensitive layer and steel as the interaction material in the hadronic calorimeter. A general trend in increased performance with more layering was also observed for the calorimeter. Also illuminated in the study was the discovery of unexpected performance for radius variations.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2008.","Includes bibliographical references (p. 51)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Using the the SLIC simulator software and the org.lcsim reconstruction framework package, the performance of Mat Charles' NonTrivialPfa.java PFA for several different detector variations was found by determining the mass resolution for a given detector geometry. The variations tested included the layering of the hadronic calorimeter, the radius of the calorimeter, the interaction material utilized in the hadronic calorimeter and the type of read-out used in the calorimeter. Based on the performance of the PFA for the different variations, the optimal detector specifications for use with the PFA were discovered. The optimal detector was found to use scintillator as the sensitive layer and steel as the interaction material in the hadronic calorimeter. A general trend in increased performance with more layering was also observed for the calorimeter. Also illuminated in the study was the discovery of unexpected performance for radius variations."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Lawrence Fernando Bronk."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["51 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Particle detector optimization via particle flow algorithms"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2ffe6b76-6406-44e9-a6da-5fbed2055315\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Particle detector optimization via particle flow algorithms</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Bronk, Lawrence Fernando</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>Using the the SLIC simulator software and the org.lcsim reconstruction framework package, the performance of Mat Charles' NonTrivialPfa.java PFA for several different detector variations was found by determining the mass resolution for a given detector geometry. The variations tested included the layering of the hadronic calorimeter, the radius of the calorimeter, the interaction material utilized in the hadronic calorimeter and the type of read-out used in the calorimeter. Based on the performance of the PFA for the different variations, the optimal detector specifications for use with the PFA were discovered. The optimal detector was found to use scintillator as the sensitive layer and steel as the interaction material in the hadronic calorimeter. A general trend in increased performance with more layering was also observed for the calorimeter. Also illuminated in the study was the discovery of unexpected performance for radius variations.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Peter Fisher."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:creator":["Bronk, Lawrence Fernando"],"dc:date.accessioned":["2009-01-30T16:49:39Z"],"dc:date.available":["2009-01-30T16:49:39Z"],"dc:date.copyright":["2008"],"dc:date.issued":["2008"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2008.","Includes bibliographical references (p. 51)."],"dc:description.abstract":["Using the the SLIC simulator software and the org.lcsim reconstruction framework package, the performance of Mat Charles' NonTrivialPfa.java PFA for several different detector variations was found by determining the mass resolution for a given detector geometry. The variations tested included the layering of the hadronic calorimeter, the radius of the calorimeter, the interaction material utilized in the hadronic calorimeter and the type of read-out used in the calorimeter. Based on the performance of the PFA for the different variations, the optimal detector specifications for use with the PFA were discovered. The optimal detector was found to use scintillator as the sensitive layer and steel as the interaction material in the hadronic calorimeter. A general trend in increased performance with more layering was also observed for the calorimeter. Also illuminated in the study was the discovery of unexpected performance for radius variations."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Lawrence Fernando Bronk."],"dc:format.extent":["51 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["297176638"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/44465"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Particle detector optimization via particle flow algorithms"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T06:22:39Z"}