{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/45748"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/45748","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina","abstract":"Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called \"Fourier domain\" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.","abstract_html":"Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called &quot;Fourier domain&quot; because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.","abstract_has_math":false,"creators":["Srinivasan, Vivek Jay"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["James G. Fujimoto."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-27T08:30:05Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["298116698"],"render_values":[{"text":"298116698","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/45748","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/45748","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F45748","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F45748","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["James G. Fujimoto."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Srinivasan, Vivek Jay"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-06-30T16:11:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-06-30T16:11:08Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2008"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["298116698"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/45748"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"475b6ade-dcb0-4cbb-8227-08d3adc42804\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina</Title> <Subtitle>High-speed Fourier domain OCT for structural and functional imaging of the retina</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Srinivasan, Vivek Jay</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called \"Fourier domain\" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.","Includes bibliographical references."]},{"key":"dc:description.abstract","label":"Abstract","values":["Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called \"Fourier domain\" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Vivek Jay Srinivasan."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["234 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["High-speed Fourier domain OCT for structural and functional imaging of the retina"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"475b6ade-dcb0-4cbb-8227-08d3adc42804\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina</Title> <Subtitle>High-speed Fourier domain OCT for structural and functional imaging of the retina</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Srinivasan, Vivek Jay</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called \"Fourier domain\" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["James G. Fujimoto."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Srinivasan, Vivek Jay"],"dc:date.accessioned":["2009-06-30T16:11:08Z"],"dc:date.available":["2009-06-30T16:11:08Z"],"dc:date.copyright":["2008"],"dc:date.issued":["2008"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2008.","Includes bibliographical references."],"dc:description.abstract":["Optical Coherence Tomography (OCT) is an emerging optical biomedical imaging technology that enables cross-sectional imaging of scattering tissue with high sensitivity and micron-scale resolution. In conventional OCT, the reference arm path length in a Michelson interferometer is scanned in time to generate a profile of backscattering versus depth from the sample arm. In conventional OCT, a broadband, low coherence light source is used to achieve high axial resolution. However, clinical and research applications of conventional OCT have been limited by low imaging speeds. Recently, new Fourier domain OCT detection methods have enabled speeds of ~20,000-40,000 axial scans per second, which are ~50-100x faster than conventional OCT. These methods are called \"Fourier domain\" because they detect the interference spectrum and do not require mechanical scanning of the reference arm path length in time. In this thesis, two different technologies for Fourier domain OCT are investigated. The first technology, called spectral OCT, uses a broadband light source and a spectrometer to measure the interference spectrum. The second technology, called swept source OCT, uses a rapidly tunable narrowband laser to measure the interference spectrum over time. Applications of these new technologies for retinal imaging are illustrated, including three-dimensional retinal imaging in animal models, clinical imaging of retinal pathologies, quantification of photoreceptor morphology, and functional imaging of intrinsic stimulus-induced scattering changes in the retina. Finally, using a rapidly tunable laser, ultrahigh-speed swept source OCT imaging at 249,000 axial scans per second, roughly three orders of magnitude faster than conventional OCT, is demonstrated. This technology is applied for three-dimensional snapshots of the retina and optic nerve head and unprecedented visualization of retinal anatomy."],"dc:description.degree":["Ph.D."],"dc:description.statementofresponsibility":["by Vivek Jay Srinivasan."],"dc:format.extent":["234 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["298116698"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/45748"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["High-speed Fourier domain Optical Coherence Tomography for structural and functional imaging of the retina"],"dc:title.alternative":["High-speed Fourier domain OCT for structural and functional imaging of the retina"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T08:30:05Z"}