{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/45794"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/45794","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Optimization of vacuum pump device for use in rapid fitment of prosthetic limbs","abstract":"Developing World Prosthetics NGO has been in contact with the Jaipur Foot Organization in order to create a human powered vacuum pump for a new technique in prosthetic fitment. The new technique would provide mobility to fitment camps due to the non-reliance of an electrical grid. The design however would need to meet the demands of third-world conditions and heavy, continuous usage. This thesis seeks to explore a variety of mechanisms in order to meet the required specifications of the JFO and the new technique.","abstract_html":"Developing World Prosthetics NGO has been in contact with the Jaipur Foot Organization in order to create a human powered vacuum pump for a new technique in prosthetic fitment. The new technique would provide mobility to fitment camps due to the non-reliance of an electrical grid. The design however would need to meet the demands of third-world conditions and heavy, continuous usage. This thesis seeks to explore a variety of mechanisms in order to meet the required specifications of the JFO and the new technique.","abstract_has_math":false,"creators":["Garcia, Philip Thomas"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Daniel Frey."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-29T16:46:24Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["318911843"],"render_values":[{"text":"318911843","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/45794","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/45794","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F45794","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F45794","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Daniel Frey."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Garcia, Philip Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-06-30T16:18:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-06-30T16:18:46Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2008"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["318911843"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/45794"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"67421eba-03a2-461b-b58f-def625951a95\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Optimization of vacuum pump device for use in rapid fitment of prosthetic limbs</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Garcia, Philip Thomas</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Developing World Prosthetics NGO has been in contact with the Jaipur Foot Organization in order to create a human powered vacuum pump for a new technique in prosthetic fitment. The new technique would provide mobility to fitment camps due to the non-reliance of an electrical grid. The design however would need to meet the demands of third-world conditions and heavy, continuous usage. This thesis seeks to explore a variety of mechanisms in order to meet the required specifications of the JFO and the new technique.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.","Includes bibliographical references (leaf 19)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Developing World Prosthetics NGO has been in contact with the Jaipur Foot Organization in order to create a human powered vacuum pump for a new technique in prosthetic fitment. The new technique would provide mobility to fitment camps due to the non-reliance of an electrical grid. The design however would need to meet the demands of third-world conditions and heavy, continuous usage. This thesis seeks to explore a variety of mechanisms in order to meet the required specifications of the JFO and the new technique."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Philip Thomas Garcia."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["19 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optimization of vacuum pump device for use in rapid fitment of prosthetic limbs"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"67421eba-03a2-461b-b58f-def625951a95\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Optimization of vacuum pump device for use in rapid fitment of prosthetic limbs</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Garcia, Philip Thomas</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Developing World Prosthetics NGO has been in contact with the Jaipur Foot Organization in order to create a human powered vacuum pump for a new technique in prosthetic fitment. The new technique would provide mobility to fitment camps due to the non-reliance of an electrical grid. The design however would need to meet the demands of third-world conditions and heavy, continuous usage. This thesis seeks to explore a variety of mechanisms in order to meet the required specifications of the JFO and the new technique.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Daniel Frey."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Garcia, Philip Thomas"],"dc:date.accessioned":["2009-06-30T16:18:46Z"],"dc:date.available":["2009-06-30T16:18:46Z"],"dc:date.copyright":["2008"],"dc:date.issued":["2008"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2008.","Includes bibliographical references (leaf 19)."],"dc:description.abstract":["Developing World Prosthetics NGO has been in contact with the Jaipur Foot Organization in order to create a human powered vacuum pump for a new technique in prosthetic fitment. The new technique would provide mobility to fitment camps due to the non-reliance of an electrical grid. The design however would need to meet the demands of third-world conditions and heavy, continuous usage. This thesis seeks to explore a variety of mechanisms in order to meet the required specifications of the JFO and the new technique."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Philip Thomas Garcia."],"dc:format.extent":["19 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["318911843"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/45794"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Optimization of vacuum pump device for use in rapid fitment of prosthetic limbs"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-29T16:46:24Z"}