{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/46526"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/46526","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Analysis of peak characterization and data alignment of a differential mobility spectrometer for the discovery of TB biomarkers in human breath","abstract":"Biomarkers have become a growing field for disease research and diagnostics. For the infectious, deadly disease, tuberculosis (TB), the discovery of effective TB biomarkers in the human breath may enable the development of a cheap, fast, and accurate TB diagnostic to fight against this epidemic. The Charles Stark Draper Laboratory is employing a differential mobility spectrometer (DMS), in order to identify key biomarkers for TB. Biomarker candidates appear as peaks in the DMS sensor data at particular retention times and DC compensation voltages. Possible biomarkers are identified through well-known classification techniques, K-nearest neighbors and support vector machines. This research is focused on the development of a toolbox that will aid in the discovery and in-depth understanding of the TB breath biomarkers. This thesis demonstrates the algorithms and capabilities of peak quantification, characterization, RIP-based alignment, and siloxane-based alignment on protein and bacterial sensor data, including those from initial Mycobacterium tuberculosis samples. The results show that siloxane-based alignment with high-intensity peak landmarks effectively increase DMS peak stabilities and signal-to-noise ratios. These new tools will be important for the analysis of specific TB biomarker candidates as our group at the Charles Stark Draper Laboratory receive more samples of M. tuberculosis.","abstract_html":"Biomarkers have become a growing field for disease research and diagnostics. For the infectious, deadly disease, tuberculosis (TB), the discovery of effective TB biomarkers in the human breath may enable the development of a cheap, fast, and accurate TB diagnostic to fight against this epidemic. The Charles Stark Draper Laboratory is employing a differential mobility spectrometer (DMS), in order to identify key biomarkers for TB. Biomarker candidates appear as peaks in the DMS sensor data at particular retention times and DC compensation voltages. Possible biomarkers are identified through well-known classification techniques, K-nearest neighbors and support vector machines. This research is focused on the development of a toolbox that will aid in the discovery and in-depth understanding of the TB breath biomarkers. This thesis demonstrates the algorithms and capabilities of peak quantification, characterization, RIP-based alignment, and siloxane-based alignment on protein and bacterial sensor data, including those from initial Mycobacterium tuberculosis samples. The results show that siloxane-based alignment with high-intensity peak landmarks effectively increase DMS peak stabilities and signal-to-noise ratios. These new tools will be important for the analysis of specific TB biomarker candidates as our group at the Charles Stark Draper Laboratory receive more samples of M. tuberculosis.","abstract_has_math":false,"creators":["Tang, Amy Yuen-Lee"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Roger G. Mark and Nirmal Keshava."],"committee_chairs":[],"committee_members":[],"year":2008,"date_issued":"2008","date_published":"2008","updated_at":"2026-11-29T16:46:52Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["414019729"],"render_values":[{"text":"414019729","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/46526","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/46526","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F46526","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F46526","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Roger G. Mark and Nirmal Keshava."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Tang, Amy Yuen-Lee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-08-26T16:42:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-08-26T16:42:30Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2007"]},{"key":"dc:date.issued","label":"Date","values":["2008"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["414019729"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/46526"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"6a30c96d-6211-46fe-95ba-55e75a6acfe6\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Analysis of peak characterization and data alignment of a differential mobility spectrometer for the discovery of TB biomarkers in human breath</Title> <Subtitle>Alignment, feature stability and algorithms of a differential mobility spectrometer for the discovery of tuberculosis biomarkers</Subtitle> <Subtitle>DMS for the discovery of TB biomarkers in human breath</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Tang, Amy Yuen-Lee</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>Biomarkers have become a growing field for disease research and diagnostics. For the infectious, deadly disease, tuberculosis (TB), the discovery of effective TB biomarkers in the human breath may enable the development of a cheap, fast, and accurate TB diagnostic to fight against this epidemic. The Charles Stark Draper Laboratory is employing a differential mobility spectrometer (DMS), in order to identify key biomarkers for TB. Biomarker candidates appear as peaks in the DMS sensor data at particular retention times and DC compensation voltages. Possible biomarkers are identified through well-known classification techniques, K-nearest neighbors and support vector machines. This research is focused on the development of a toolbox that will aid in the discovery and in-depth understanding of the TB breath biomarkers. This thesis demonstrates the algorithms and capabilities of peak quantification, characterization, RIP-based alignment, and siloxane-based alignment on protein and bacterial sensor data, including those from initial Mycobacterium tuberculosis samples. The results show that siloxane-based alignment with high-intensity peak landmarks effectively increase DMS peak stabilities and signal-to-noise ratios. These new tools will be important for the analysis of specific TB biomarker candidates as our group at the Charles Stark Draper Laboratory receive more samples of M. tuberculosis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 2008.","Includes bibliographical references (p. 71-73)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Biomarkers have become a growing field for disease research and diagnostics. For the infectious, deadly disease, tuberculosis (TB), the discovery of effective TB biomarkers in the human breath may enable the development of a cheap, fast, and accurate TB diagnostic to fight against this epidemic. The Charles Stark Draper Laboratory is employing a differential mobility spectrometer (DMS), in order to identify key biomarkers for TB. Biomarker candidates appear as peaks in the DMS sensor data at particular retention times and DC compensation voltages. Possible biomarkers are identified through well-known classification techniques, K-nearest neighbors and support vector machines. This research is focused on the development of a toolbox that will aid in the discovery and in-depth understanding of the TB breath biomarkers. This thesis demonstrates the algorithms and capabilities of peak quantification, characterization, RIP-based alignment, and siloxane-based alignment on protein and bacterial sensor data, including those from initial Mycobacterium tuberculosis samples. The results show that siloxane-based alignment with high-intensity peak landmarks effectively increase DMS peak stabilities and signal-to-noise ratios. These new tools will be important for the analysis of specific TB biomarker candidates as our group at the Charles Stark Draper Laboratory receive more samples of M. tuberculosis."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Amy Yuen-Lee Tang."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["73 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analysis of peak characterization and data alignment of a differential mobility spectrometer for the discovery of TB biomarkers in human breath"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Alignment, feature stability and algorithms of a differential mobility spectrometer for the discovery of tuberculosis biomarkers","DMS for the discovery of TB biomarkers in human breath"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"6a30c96d-6211-46fe-95ba-55e75a6acfe6\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Analysis of peak characterization and data alignment of a differential mobility spectrometer for the discovery of TB biomarkers in human breath</Title> <Subtitle>Alignment, feature stability and algorithms of a differential mobility spectrometer for the discovery of tuberculosis biomarkers</Subtitle> <Subtitle>DMS for the discovery of TB biomarkers in human breath</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2008</PublicationDate> <Authors> <Author> <DisplayName>Tang, Amy Yuen-Lee</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>Biomarkers have become a growing field for disease research and diagnostics. For the infectious, deadly disease, tuberculosis (TB), the discovery of effective TB biomarkers in the human breath may enable the development of a cheap, fast, and accurate TB diagnostic to fight against this epidemic. The Charles Stark Draper Laboratory is employing a differential mobility spectrometer (DMS), in order to identify key biomarkers for TB. Biomarker candidates appear as peaks in the DMS sensor data at particular retention times and DC compensation voltages. Possible biomarkers are identified through well-known classification techniques, K-nearest neighbors and support vector machines. This research is focused on the development of a toolbox that will aid in the discovery and in-depth understanding of the TB breath biomarkers. This thesis demonstrates the algorithms and capabilities of peak quantification, characterization, RIP-based alignment, and siloxane-based alignment on protein and bacterial sensor data, including those from initial Mycobacterium tuberculosis samples. The results show that siloxane-based alignment with high-intensity peak landmarks effectively increase DMS peak stabilities and signal-to-noise ratios. These new tools will be important for the analysis of specific TB biomarker candidates as our group at the Charles Stark Draper Laboratory receive more samples of M. tuberculosis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Roger G. Mark and Nirmal Keshava."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Tang, Amy Yuen-Lee"],"dc:date.accessioned":["2009-08-26T16:42:30Z"],"dc:date.available":["2009-08-26T16:42:30Z"],"dc:date.copyright":["2007"],"dc:date.issued":["2008"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, February 2008.","Includes bibliographical references (p. 71-73)."],"dc:description.abstract":["Biomarkers have become a growing field for disease research and diagnostics. For the infectious, deadly disease, tuberculosis (TB), the discovery of effective TB biomarkers in the human breath may enable the development of a cheap, fast, and accurate TB diagnostic to fight against this epidemic. The Charles Stark Draper Laboratory is employing a differential mobility spectrometer (DMS), in order to identify key biomarkers for TB. Biomarker candidates appear as peaks in the DMS sensor data at particular retention times and DC compensation voltages. Possible biomarkers are identified through well-known classification techniques, K-nearest neighbors and support vector machines. This research is focused on the development of a toolbox that will aid in the discovery and in-depth understanding of the TB breath biomarkers. This thesis demonstrates the algorithms and capabilities of peak quantification, characterization, RIP-based alignment, and siloxane-based alignment on protein and bacterial sensor data, including those from initial Mycobacterium tuberculosis samples. The results show that siloxane-based alignment with high-intensity peak landmarks effectively increase DMS peak stabilities and signal-to-noise ratios. These new tools will be important for the analysis of specific TB biomarker candidates as our group at the Charles Stark Draper Laboratory receive more samples of M. tuberculosis."],"dc:description.degree":["M.Eng."],"dc:description.statementofresponsibility":["by Amy Yuen-Lee Tang."],"dc:format.extent":["73 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["414019729"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/46526"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Analysis of peak characterization and data alignment of a differential mobility spectrometer for the discovery of TB biomarkers in human breath"],"dc:title.alternative":["Alignment, feature stability and algorithms of a differential mobility spectrometer for the discovery of tuberculosis biomarkers","DMS for the discovery of TB biomarkers in human breath"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-29T16:46:52Z"}