{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/47815"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/47815","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Development of an integrated capillary valve-based preconcentrator and surface-based immunoassay","abstract":"A new generation of integrated preconcentrator and immunoassay was developed. A novel, self-aligned method for patterning Nafion resin was developed and applied to create a preconcentrator. In a parallel effort, a surface-based immunoassay was developed and optimized for use with the preconcentrator. Experiments were carried out with R-phycoerythrin (R-PE) to characterize the performance of the integrated preconcentrator and immunoassay. The immunoassay originally has a detection limit of Ing/mL of R-PE in 1xPBS. When coupled to the preconcentrator, this limit has been improved to 0.Olng/mL, a roughly 100x improvement. Discussions of the differences between this and previous generations of concentrators are also presented in this thesis.","abstract_html":"A new generation of integrated preconcentrator and immunoassay was developed. A novel, self-aligned method for patterning Nafion resin was developed and applied to create a preconcentrator. In a parallel effort, a surface-based immunoassay was developed and optimized for use with the preconcentrator. Experiments were carried out with R-phycoerythrin (R-PE) to characterize the performance of the integrated preconcentrator and immunoassay. The immunoassay originally has a detection limit of Ing/mL of R-PE in 1xPBS. When coupled to the preconcentrator, this limit has been improved to 0.Olng/mL, a roughly 100x improvement. Discussions of the differences between this and previous generations of concentrators are also presented in this thesis.","abstract_has_math":false,"creators":["Liu, Vincent Hok"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Jongyoon Han."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-27T06:23:50Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["429466732"],"render_values":[{"text":"429466732","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/47815","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/47815","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F47815","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F47815","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jongyoon Han."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Liu, Vincent Hok"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2009-10-01T15:46:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2009-10-01T15:46:24Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["429466732"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/47815"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3f320104-916f-4131-91ec-6ae6e438e2f1\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Development of an integrated capillary valve-based preconcentrator and surface-based immunoassay</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Liu, Vincent Hok</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>A new generation of integrated preconcentrator and immunoassay was developed. A novel, self-aligned method for patterning Nafion resin was developed and applied to create a preconcentrator. In a parallel effort, a surface-based immunoassay was developed and optimized for use with the preconcentrator. Experiments were carried out with R-phycoerythrin (R-PE) to characterize the performance of the integrated preconcentrator and immunoassay. The immunoassay originally has a detection limit of Ing/mL of R-PE in 1xPBS. When coupled to the preconcentrator, this limit has been improved to 0.Olng/mL, a roughly 100x improvement. Discussions of the differences between this and previous generations of concentrators are also presented in this thesis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.","Includes bibliographical references (leaves 60-61)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A new generation of integrated preconcentrator and immunoassay was developed. A novel, self-aligned method for patterning Nafion resin was developed and applied to create a preconcentrator. In a parallel effort, a surface-based immunoassay was developed and optimized for use with the preconcentrator. Experiments were carried out with R-phycoerythrin (R-PE) to characterize the performance of the integrated preconcentrator and immunoassay. The immunoassay originally has a detection limit of Ing/mL of R-PE in 1xPBS. When coupled to the preconcentrator, this limit has been improved to 0.Olng/mL, a roughly 100x improvement. Discussions of the differences between this and previous generations of concentrators are also presented in this thesis."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Vincent Hok Liu."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["61 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of an integrated capillary valve-based preconcentrator and surface-based immunoassay"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3f320104-916f-4131-91ec-6ae6e438e2f1\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Development of an integrated capillary valve-based preconcentrator and surface-based immunoassay</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Liu, Vincent Hok</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>A new generation of integrated preconcentrator and immunoassay was developed. A novel, self-aligned method for patterning Nafion resin was developed and applied to create a preconcentrator. In a parallel effort, a surface-based immunoassay was developed and optimized for use with the preconcentrator. Experiments were carried out with R-phycoerythrin (R-PE) to characterize the performance of the integrated preconcentrator and immunoassay. The immunoassay originally has a detection limit of Ing/mL of R-PE in 1xPBS. When coupled to the preconcentrator, this limit has been improved to 0.Olng/mL, a roughly 100x improvement. Discussions of the differences between this and previous generations of concentrators are also presented in this thesis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Jongyoon Han."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Liu, Vincent Hok"],"dc:date.accessioned":["2009-10-01T15:46:24Z"],"dc:date.available":["2009-10-01T15:46:24Z"],"dc:date.copyright":["2009"],"dc:date.issued":["2009"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.","Includes bibliographical references (leaves 60-61)."],"dc:description.abstract":["A new generation of integrated preconcentrator and immunoassay was developed. A novel, self-aligned method for patterning Nafion resin was developed and applied to create a preconcentrator. In a parallel effort, a surface-based immunoassay was developed and optimized for use with the preconcentrator. Experiments were carried out with R-phycoerythrin (R-PE) to characterize the performance of the integrated preconcentrator and immunoassay. The immunoassay originally has a detection limit of Ing/mL of R-PE in 1xPBS. When coupled to the preconcentrator, this limit has been improved to 0.Olng/mL, a roughly 100x improvement. Discussions of the differences between this and previous generations of concentrators are also presented in this thesis."],"dc:description.degree":["S.M."],"dc:description.statementofresponsibility":["by Vincent Hok Liu."],"dc:format.extent":["61 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["429466732"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/47815"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Development of an integrated capillary valve-based preconcentrator and surface-based immunoassay"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T06:23:50Z"}