{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/50619"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/50619","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Renovation proposal for Fenway Park","abstract":"As the oldest stadium in baseball history, the existing structure of Fenway Park presents problems such as limiting seating capacity and obstructed views, caused by the columns supporting the second level. Opened in 1912, this stadium is considered one of today's most historical sporting venues. In 2005, the Red Sox ownership announced that the stadium would remain as the home of the Red Sox for years to come. Consequently, considerable investments were made into the stadium to increase seating capacity and to retrofit the structure. This thesis explores the aforementioned main problems, the seating capacity and the obstructed view, and proposes a new design for the seating deck. Two options are explored: one scheme is a stiff structure with concentric bracing and the second scheme is a flexible structure that implements a Tuned Mass Damper to mitigate the vibrations of the cantilevered deck. A design proposal is presented with standard steel sections. It is concluded that the second option is not feasible because it does not comply with the deflection criterion.","abstract_html":"As the oldest stadium in baseball history, the existing structure of Fenway Park presents problems such as limiting seating capacity and obstructed views, caused by the columns supporting the second level. Opened in 1912, this stadium is considered one of today&#x27;s most historical sporting venues. In 2005, the Red Sox ownership announced that the stadium would remain as the home of the Red Sox for years to come. Consequently, considerable investments were made into the stadium to increase seating capacity and to retrofit the structure. This thesis explores the aforementioned main problems, the seating capacity and the obstructed view, and proposes a new design for the seating deck. Two options are explored: one scheme is a stiff structure with concentric bracing and the second scheme is a flexible structure that implements a Tuned Mass Damper to mitigate the vibrations of the cantilevered deck. A design proposal is presented with standard steel sections. It is concluded that the second option is not feasible because it does not comply with the deflection criterion.","abstract_has_math":false,"creators":["Aldana Urrutia, Luis Pedro"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Jerome J. Connor."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-29T16:46:55Z","subjects":["Civil and Environmental Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["475653572"],"render_values":[{"text":"475653572","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/50619","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/50619","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F50619","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F50619","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jerome J. Connor."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."]},{"key":"dc:creator","label":"Author","values":["Aldana Urrutia, Luis Pedro"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:coverage.spatial","label":"Dc Coverage Spatial","values":["n-us-ma"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-01-07T21:02:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-07T21:02:00Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil and Environmental Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["475653572"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/50619"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"6ad3af1b-25d8-4352-a965-21de5a1e6f59\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Renovation proposal for Fenway Park</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Aldana Urrutia, Luis Pedro</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Civil and Environmental Engineering.</Keyword> <Abstract>As the oldest stadium in baseball history, the existing structure of Fenway Park presents problems such as limiting seating capacity and obstructed views, caused by the columns supporting the second level. Opened in 1912, this stadium is considered one of today's most historical sporting venues. In 2005, the Red Sox ownership announced that the stadium would remain as the home of the Red Sox for years to come. Consequently, considerable investments were made into the stadium to increase seating capacity and to retrofit the structure. This thesis explores the aforementioned main problems, the seating capacity and the obstructed view, and proposes a new design for the seating deck. Two options are explored: one scheme is a stiff structure with concentric bracing and the second scheme is a flexible structure that implements a Tuned Mass Damper to mitigate the vibrations of the cantilevered deck. A design proposal is presented with standard steel sections. It is concluded that the second option is not feasible because it does not comply with the deflection criterion.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2009.","Includes bibliographical references (leaf 39)."]},{"key":"dc:description.abstract","label":"Abstract","values":["As the oldest stadium in baseball history, the existing structure of Fenway Park presents problems such as limiting seating capacity and obstructed views, caused by the columns supporting the second level. Opened in 1912, this stadium is considered one of today's most historical sporting venues. In 2005, the Red Sox ownership announced that the stadium would remain as the home of the Red Sox for years to come. Consequently, considerable investments were made into the stadium to increase seating capacity and to retrofit the structure. This thesis explores the aforementioned main problems, the seating capacity and the obstructed view, and proposes a new design for the seating deck. Two options are explored: one scheme is a stiff structure with concentric bracing and the second scheme is a flexible structure that implements a Tuned Mass Damper to mitigate the vibrations of the cantilevered deck. A design proposal is presented with standard steel sections. It is concluded that the second option is not feasible because it does not comply with the deflection criterion."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Luis Pedro Aldana Urrutia."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["49 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Renovation proposal for Fenway Park"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"6ad3af1b-25d8-4352-a965-21de5a1e6f59\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Renovation proposal for Fenway Park</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Aldana Urrutia, Luis Pedro</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Civil and Environmental Engineering.</Keyword> <Abstract>As the oldest stadium in baseball history, the existing structure of Fenway Park presents problems such as limiting seating capacity and obstructed views, caused by the columns supporting the second level. Opened in 1912, this stadium is considered one of today's most historical sporting venues. In 2005, the Red Sox ownership announced that the stadium would remain as the home of the Red Sox for years to come. Consequently, considerable investments were made into the stadium to increase seating capacity and to retrofit the structure. This thesis explores the aforementioned main problems, the seating capacity and the obstructed view, and proposes a new design for the seating deck. Two options are explored: one scheme is a stiff structure with concentric bracing and the second scheme is a flexible structure that implements a Tuned Mass Damper to mitigate the vibrations of the cantilevered deck. A design proposal is presented with standard steel sections. It is concluded that the second option is not feasible because it does not comply with the deflection criterion.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Jerome J. Connor."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Civil and Environmental Engineering."],"dc:coverage.spatial":["n-us-ma"],"dc:creator":["Aldana Urrutia, Luis Pedro"],"dc:date.accessioned":["2010-01-07T21:02:00Z"],"dc:date.available":["2010-01-07T21:02:00Z"],"dc:date.copyright":["2009"],"dc:date.issued":["2009"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2009.","Includes bibliographical references (leaf 39)."],"dc:description.abstract":["As the oldest stadium in baseball history, the existing structure of Fenway Park presents problems such as limiting seating capacity and obstructed views, caused by the columns supporting the second level. Opened in 1912, this stadium is considered one of today's most historical sporting venues. In 2005, the Red Sox ownership announced that the stadium would remain as the home of the Red Sox for years to come. Consequently, considerable investments were made into the stadium to increase seating capacity and to retrofit the structure. This thesis explores the aforementioned main problems, the seating capacity and the obstructed view, and proposes a new design for the seating deck. Two options are explored: one scheme is a stiff structure with concentric bracing and the second scheme is a flexible structure that implements a Tuned Mass Damper to mitigate the vibrations of the cantilevered deck. A design proposal is presented with standard steel sections. It is concluded that the second option is not feasible because it does not comply with the deflection criterion."],"dc:description.degree":["M.Eng."],"dc:description.statementofresponsibility":["by Luis Pedro Aldana Urrutia."],"dc:format.extent":["49 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["475653572"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/50619"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Civil and Environmental Engineering."],"dc:title":["Renovation proposal for Fenway Park"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-29T16:46:55Z"}