{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/54456"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/54456","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"The analysis and design of a pressure-measuring syringe utilizing elastomeric bellows","abstract":"Endotracheal tube insertion requires the measurement of very low pressure. Currently, there exists no reliable method or device that is integral with the inflation syringe for measuring this pressure. Thus, a device for quickly and easily reading the pressure was created within the syringe currently used to pressurize the tube. This device takes the form of elastomeric bellows. These bellows were analyzed to determine the optimum geometry for the pressures involved in the procedure. Although no closed-form model exists for this analysis, FEA was used to obtain accurate results. Using the optimized bellows, a complete for-manufacturing design was created. This design concept has received much acclaim from the medical community and has great promise in transforming many medical procedures which require such measurement..","abstract_html":"Endotracheal tube insertion requires the measurement of very low pressure. Currently, there exists no reliable method or device that is integral with the inflation syringe for measuring this pressure. Thus, a device for quickly and easily reading the pressure was created within the syringe currently used to pressurize the tube. This device takes the form of elastomeric bellows. These bellows were analyzed to determine the optimum geometry for the pressures involved in the procedure. Although no closed-form model exists for this analysis, FEA was used to obtain accurate results. Using the optimized bellows, a complete for-manufacturing design was created. This design concept has received much acclaim from the medical community and has great promise in transforming many medical procedures which require such measurement..","abstract_has_math":false,"creators":["Duffley, Samuel C"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Alex Slocum."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-27T03:17:09Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["551163231"],"render_values":[{"text":"551163231","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/54456","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/54456","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F54456","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F54456","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Alex Slocum."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Duffley, Samuel C"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-04-28T15:35:17Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-04-28T15:35:17Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["551163231"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/54456"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"07e8f449-6905-41fc-9b26-3abe2346ba83\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>The analysis and design of a pressure-measuring syringe utilizing elastomeric bellows</Title> <Subtitle>Pressure-measuring syringe utilizing elastomeric bellows</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Duffley, Samuel C</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Endotracheal tube insertion requires the measurement of very low pressure. Currently, there exists no reliable method or device that is integral with the inflation syringe for measuring this pressure. Thus, a device for quickly and easily reading the pressure was created within the syringe currently used to pressurize the tube. This device takes the form of elastomeric bellows. These bellows were analyzed to determine the optimum geometry for the pressures involved in the procedure. Although no closed-form model exists for this analysis, FEA was used to obtain accurate results. Using the optimized bellows, a complete for-manufacturing design was created. This design concept has received much acclaim from the medical community and has great promise in transforming many medical procedures which require such measurement..</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 28)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Endotracheal tube insertion requires the measurement of very low pressure. Currently, there exists no reliable method or device that is integral with the inflation syringe for measuring this pressure. Thus, a device for quickly and easily reading the pressure was created within the syringe currently used to pressurize the tube. This device takes the form of elastomeric bellows. These bellows were analyzed to determine the optimum geometry for the pressures involved in the procedure. Although no closed-form model exists for this analysis, FEA was used to obtain accurate results. Using the optimized bellows, a complete for-manufacturing design was created. This design concept has received much acclaim from the medical community and has great promise in transforming many medical procedures which require such measurement.."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Samuel C. Duffley."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["28 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The analysis and design of a pressure-measuring syringe utilizing elastomeric bellows"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Pressure-measuring syringe utilizing elastomeric bellows"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"07e8f449-6905-41fc-9b26-3abe2346ba83\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>The analysis and design of a pressure-measuring syringe utilizing elastomeric bellows</Title> <Subtitle>Pressure-measuring syringe utilizing elastomeric bellows</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Duffley, Samuel C</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Endotracheal tube insertion requires the measurement of very low pressure. Currently, there exists no reliable method or device that is integral with the inflation syringe for measuring this pressure. Thus, a device for quickly and easily reading the pressure was created within the syringe currently used to pressurize the tube. This device takes the form of elastomeric bellows. These bellows were analyzed to determine the optimum geometry for the pressures involved in the procedure. Although no closed-form model exists for this analysis, FEA was used to obtain accurate results. Using the optimized bellows, a complete for-manufacturing design was created. This design concept has received much acclaim from the medical community and has great promise in transforming many medical procedures which require such measurement..</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Alex Slocum."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Duffley, Samuel C"],"dc:date.accessioned":["2010-04-28T15:35:17Z"],"dc:date.available":["2010-04-28T15:35:17Z"],"dc:date.copyright":["2009"],"dc:date.issued":["2009"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 28)."],"dc:description.abstract":["Endotracheal tube insertion requires the measurement of very low pressure. Currently, there exists no reliable method or device that is integral with the inflation syringe for measuring this pressure. Thus, a device for quickly and easily reading the pressure was created within the syringe currently used to pressurize the tube. This device takes the form of elastomeric bellows. These bellows were analyzed to determine the optimum geometry for the pressures involved in the procedure. Although no closed-form model exists for this analysis, FEA was used to obtain accurate results. Using the optimized bellows, a complete for-manufacturing design was created. This design concept has received much acclaim from the medical community and has great promise in transforming many medical procedures which require such measurement.."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Samuel C. Duffley."],"dc:format.extent":["28 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["551163231"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/54456"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["The analysis and design of a pressure-measuring syringe utilizing elastomeric bellows"],"dc:title.alternative":["Pressure-measuring syringe utilizing elastomeric bellows"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T03:17:09Z"}