{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/59904"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/59904","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Tubing analysis and selection process for the frame of the IXA walker","abstract":"A thorough analysis and test of the frame for a walker was conducted in order to select the optimal size tubing for the walker. Initially a rough first order bending analysis was completed to make an initial decision on tubing size. Finite element analysis was done on the tubing selected to confirm the theory of the first order analytical model, and to determine the expected deflection. A test rig was then built with a 1:1 scale frame in order to test the actual deflection of the frame. Weights were used to measure the deflection for masses varying from 0 lbs to 150 lbs. The results of the complete analysis and testing show that a 1.5\" outer diameter by 1.26\" inner diameter tube will optimally meet the deflection and weight requirements of the walker. The experimental results are within 5% error of the expected deflection from the finite element analysis, while the quick first order analysis was within 7% of the results from the finite element analysis.","abstract_html":"A thorough analysis and test of the frame for a walker was conducted in order to select the optimal size tubing for the walker. Initially a rough first order bending analysis was completed to make an initial decision on tubing size. Finite element analysis was done on the tubing selected to confirm the theory of the first order analytical model, and to determine the expected deflection. A test rig was then built with a 1:1 scale frame in order to test the actual deflection of the frame. Weights were used to measure the deflection for masses varying from 0 lbs to 150 lbs. The results of the complete analysis and testing show that a 1.5&quot; outer diameter by 1.26&quot; inner diameter tube will optimally meet the deflection and weight requirements of the walker. The experimental results are within 5% error of the expected deflection from the finite element analysis, while the quick first order analysis was within 7% of the results from the finite element analysis.","abstract_has_math":false,"creators":["Cummings, Lucas (Lucas Robert)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Warren P. Seering."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-27T05:21:09Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["676694976"],"render_values":[{"text":"676694976","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/59904","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/59904","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F59904","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F59904","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Warren P. Seering."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Cummings, Lucas (Lucas Robert)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2010-11-08T17:43:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2010-11-08T17:43:40Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2010"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["676694976"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/59904"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2632d4e7-5bd7-46d9-a2da-3abf4e98100e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Tubing analysis and selection process for the frame of the IXA walker</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2010</PublicationDate> <Authors> <Author> <DisplayName>Cummings, Lucas (Lucas Robert)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>A thorough analysis and test of the frame for a walker was conducted in order to select the optimal size tubing for the walker. Initially a rough first order bending analysis was completed to make an initial decision on tubing size. Finite element analysis was done on the tubing selected to confirm the theory of the first order analytical model, and to determine the expected deflection. A test rig was then built with a 1:1 scale frame in order to test the actual deflection of the frame. Weights were used to measure the deflection for masses varying from 0 lbs to 150 lbs. The results of the complete analysis and testing show that a 1.5\" outer diameter by 1.26\" inner diameter tube will optimally meet the deflection and weight requirements of the walker. The experimental results are within 5% error of the expected deflection from the finite element analysis, while the quick first order analysis was within 7% of the results from the finite element analysis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.","Cataloged from PDF version of thesis."]},{"key":"dc:description.abstract","label":"Abstract","values":["A thorough analysis and test of the frame for a walker was conducted in order to select the optimal size tubing for the walker. Initially a rough first order bending analysis was completed to make an initial decision on tubing size. Finite element analysis was done on the tubing selected to confirm the theory of the first order analytical model, and to determine the expected deflection. A test rig was then built with a 1:1 scale frame in order to test the actual deflection of the frame. Weights were used to measure the deflection for masses varying from 0 lbs to 150 lbs. The results of the complete analysis and testing show that a 1.5\" outer diameter by 1.26\" inner diameter tube will optimally meet the deflection and weight requirements of the walker. The experimental results are within 5% error of the expected deflection from the finite element analysis, while the quick first order analysis was within 7% of the results from the finite element analysis."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Lucas Cummings."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["19 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Tubing analysis and selection process for the frame of the IXA walker"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"2632d4e7-5bd7-46d9-a2da-3abf4e98100e\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Tubing analysis and selection process for the frame of the IXA walker</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2010</PublicationDate> <Authors> <Author> <DisplayName>Cummings, Lucas (Lucas Robert)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>A thorough analysis and test of the frame for a walker was conducted in order to select the optimal size tubing for the walker. Initially a rough first order bending analysis was completed to make an initial decision on tubing size. Finite element analysis was done on the tubing selected to confirm the theory of the first order analytical model, and to determine the expected deflection. A test rig was then built with a 1:1 scale frame in order to test the actual deflection of the frame. Weights were used to measure the deflection for masses varying from 0 lbs to 150 lbs. The results of the complete analysis and testing show that a 1.5\" outer diameter by 1.26\" inner diameter tube will optimally meet the deflection and weight requirements of the walker. The experimental results are within 5% error of the expected deflection from the finite element analysis, while the quick first order analysis was within 7% of the results from the finite element analysis.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Warren P. Seering."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Cummings, Lucas (Lucas Robert)"],"dc:date.accessioned":["2010-11-08T17:43:40Z"],"dc:date.available":["2010-11-08T17:43:40Z"],"dc:date.copyright":["2010"],"dc:date.issued":["2010"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2010.","Cataloged from PDF version of thesis."],"dc:description.abstract":["A thorough analysis and test of the frame for a walker was conducted in order to select the optimal size tubing for the walker. Initially a rough first order bending analysis was completed to make an initial decision on tubing size. Finite element analysis was done on the tubing selected to confirm the theory of the first order analytical model, and to determine the expected deflection. A test rig was then built with a 1:1 scale frame in order to test the actual deflection of the frame. Weights were used to measure the deflection for masses varying from 0 lbs to 150 lbs. The results of the complete analysis and testing show that a 1.5\" outer diameter by 1.26\" inner diameter tube will optimally meet the deflection and weight requirements of the walker. The experimental results are within 5% error of the expected deflection from the finite element analysis, while the quick first order analysis was within 7% of the results from the finite element analysis."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Lucas Cummings."],"dc:format.extent":["19 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["676694976"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/59904"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Tubing analysis and selection process for the frame of the IXA walker"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T05:21:09Z"}