{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/61256"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/61256","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Point by point gain calibration of the Dark Matter Time Projection Chamber","abstract":"Since 1975 a growing body of astronomical evidence has given increasing credibility to the existence of dark matter. Once a simple proposition by Fritz Zwicky to explain discrepancies in the virial motion of galaxy clusters, dark matter can now explain galactic rotation curves, the hierarchical structure of the universe, and the gravitational lensing of the bullet cluster. Nonetheless, the exact particulate nature of dark matter remains a mystery. The Dark Matter Time Projection Chamber (DMTPC) is a directional detection experiment that will be able to measure the energy, length, and direction of nuclear recoil tracks induced by incoming weakly interacting massive particles (WIMPs). In this thesis I analyze nonuniformities in the CCD images used to record the nuclear recoils. I then identify the source of the nonuniformities and describe a method for calibrating the CCD images. The method improves the energy resolution by decreasing the uncertainty by a factor of 4 for the bottom time projection chamber (TPC) and a factor of 3 for the top TPC.","abstract_html":"Since 1975 a growing body of astronomical evidence has given increasing credibility to the existence of dark matter. Once a simple proposition by Fritz Zwicky to explain discrepancies in the virial motion of galaxy clusters, dark matter can now explain galactic rotation curves, the hierarchical structure of the universe, and the gravitational lensing of the bullet cluster. Nonetheless, the exact particulate nature of dark matter remains a mystery. The Dark Matter Time Projection Chamber (DMTPC) is a directional detection experiment that will be able to measure the energy, length, and direction of nuclear recoil tracks induced by incoming weakly interacting massive particles (WIMPs). In this thesis I analyze nonuniformities in the CCD images used to record the nuclear recoils. I then identify the source of the nonuniformities and describe a method for calibrating the CCD images. The method improves the energy resolution by decreasing the uncertainty by a factor of 4 for the bottom time projection chamber (TPC) and a factor of 3 for the top TPC.","abstract_has_math":false,"creators":["Lee, Albert H. (Albert Hyunjick)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Gabriella Sciolla."],"committee_chairs":[],"committee_members":[],"year":2010,"date_issued":"2010","date_published":"2010","updated_at":"2026-11-27T23:30:30Z","subjects":["Physics."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["701908252"],"render_values":[{"text":"701908252","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/61256","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/61256","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F61256","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F61256","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gabriella Sciolla."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:creator","label":"Author","values":["Lee, Albert H. (Albert Hyunjick)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-02-23T14:37:29Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-02-23T14:37:29Z"]},{"key":"dc:date.issued","label":"Date","values":["2010"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["701908252"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/61256"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4c744e43-a06f-4fb2-b1a8-4140eb5cd81c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Point by point gain calibration of the Dark Matter Time Projection Chamber</Title> <Subtitle>Point by point gain calibration of the DMTPC</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2010</PublicationDate> <Authors> <Author> <DisplayName>Lee, Albert H. (Albert Hyunjick)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>Since 1975 a growing body of astronomical evidence has given increasing credibility to the existence of dark matter. Once a simple proposition by Fritz Zwicky to explain discrepancies in the virial motion of galaxy clusters, dark matter can now explain galactic rotation curves, the hierarchical structure of the universe, and the gravitational lensing of the bullet cluster. Nonetheless, the exact particulate nature of dark matter remains a mystery. The Dark Matter Time Projection Chamber (DMTPC) is a directional detection experiment that will be able to measure the energy, length, and direction of nuclear recoil tracks induced by incoming weakly interacting massive particles (WIMPs). In this thesis I analyze nonuniformities in the CCD images used to record the nuclear recoils. I then identify the source of the nonuniformities and describe a method for calibrating the CCD images. The method improves the energy resolution by decreasing the uncertainty by a factor of 4 for the bottom time projection chamber (TPC) and a factor of 3 for the top TPC.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2010.","\"May 7, 2010.\" Cataloged from PDF version of thesis.","Includes bibliographical references (p. 52-53)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Since 1975 a growing body of astronomical evidence has given increasing credibility to the existence of dark matter. Once a simple proposition by Fritz Zwicky to explain discrepancies in the virial motion of galaxy clusters, dark matter can now explain galactic rotation curves, the hierarchical structure of the universe, and the gravitational lensing of the bullet cluster. Nonetheless, the exact particulate nature of dark matter remains a mystery. The Dark Matter Time Projection Chamber (DMTPC) is a directional detection experiment that will be able to measure the energy, length, and direction of nuclear recoil tracks induced by incoming weakly interacting massive particles (WIMPs). In this thesis I analyze nonuniformities in the CCD images used to record the nuclear recoils. I then identify the source of the nonuniformities and describe a method for calibrating the CCD images. The method improves the energy resolution by decreasing the uncertainty by a factor of 4 for the bottom time projection chamber (TPC) and a factor of 3 for the top TPC."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Albert H. Lee."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["53 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Point by point gain calibration of the Dark Matter Time Projection Chamber"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Point by point gain calibration of the DMTPC"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"4c744e43-a06f-4fb2-b1a8-4140eb5cd81c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Point by point gain calibration of the Dark Matter Time Projection Chamber</Title> <Subtitle>Point by point gain calibration of the DMTPC</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2010</PublicationDate> <Authors> <Author> <DisplayName>Lee, Albert H. (Albert Hyunjick)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>Since 1975 a growing body of astronomical evidence has given increasing credibility to the existence of dark matter. Once a simple proposition by Fritz Zwicky to explain discrepancies in the virial motion of galaxy clusters, dark matter can now explain galactic rotation curves, the hierarchical structure of the universe, and the gravitational lensing of the bullet cluster. Nonetheless, the exact particulate nature of dark matter remains a mystery. The Dark Matter Time Projection Chamber (DMTPC) is a directional detection experiment that will be able to measure the energy, length, and direction of nuclear recoil tracks induced by incoming weakly interacting massive particles (WIMPs). In this thesis I analyze nonuniformities in the CCD images used to record the nuclear recoils. I then identify the source of the nonuniformities and describe a method for calibrating the CCD images. The method improves the energy resolution by decreasing the uncertainty by a factor of 4 for the bottom time projection chamber (TPC) and a factor of 3 for the top TPC.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Gabriella Sciolla."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:creator":["Lee, Albert H. (Albert Hyunjick)"],"dc:date.accessioned":["2011-02-23T14:37:29Z"],"dc:date.available":["2011-02-23T14:37:29Z"],"dc:date.issued":["2010"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2010.","\"May 7, 2010.\" Cataloged from PDF version of thesis.","Includes bibliographical references (p. 52-53)."],"dc:description.abstract":["Since 1975 a growing body of astronomical evidence has given increasing credibility to the existence of dark matter. Once a simple proposition by Fritz Zwicky to explain discrepancies in the virial motion of galaxy clusters, dark matter can now explain galactic rotation curves, the hierarchical structure of the universe, and the gravitational lensing of the bullet cluster. Nonetheless, the exact particulate nature of dark matter remains a mystery. The Dark Matter Time Projection Chamber (DMTPC) is a directional detection experiment that will be able to measure the energy, length, and direction of nuclear recoil tracks induced by incoming weakly interacting massive particles (WIMPs). In this thesis I analyze nonuniformities in the CCD images used to record the nuclear recoils. I then identify the source of the nonuniformities and describe a method for calibrating the CCD images. The method improves the energy resolution by decreasing the uncertainty by a factor of 4 for the bottom time projection chamber (TPC) and a factor of 3 for the top TPC."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Albert H. Lee."],"dc:format.extent":["53 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["701908252"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/61256"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Point by point gain calibration of the Dark Matter Time Projection Chamber"],"dc:title.alternative":["Point by point gain calibration of the DMTPC"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T23:30:30Z"}