{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/61313"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/61313","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"An analog and digital data acquisition system for Non-Intrusive Load Monitoring","abstract":"Non-Intrusive Load Monitoring (NILM) is a method for characterizing and monitoring discrete loads connected to a power distribution system. This can include a ship, a car, or a utility distribution system. The entire concept is predicated on having access to digital samples of the current and voltage signals at the distribution point. This thesis presents a analog to digital converter for this task and a new low-power inductive current sensor for deployment in a standard circuit breaker box. The current sensor uses discrete JFET devices to passively transmit data inductively through the steel door of the circuit breaker.","abstract_html":"Non-Intrusive Load Monitoring (NILM) is a method for characterizing and monitoring discrete loads connected to a power distribution system. This can include a ship, a car, or a utility distribution system. The entire concept is predicated on having access to digital samples of the current and voltage signals at the distribution point. This thesis presents a analog to digital converter for this task and a new low-power inductive current sensor for deployment in a standard circuit breaker box. The current sensor uses discrete JFET devices to passively transmit data inductively through the steel door of the circuit breaker.","abstract_has_math":false,"creators":["Clifford, Zachary Alan"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Steven B. Leeb, John Cooley and James Paris."],"committee_chairs":[],"committee_members":[],"year":2009,"date_issued":"2009","date_published":"2009","updated_at":"2026-11-27T03:17:24Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["702680855"],"render_values":[{"text":"702680855","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/61313","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/61313","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F61313","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F61313","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Steven B. Leeb, John Cooley and James Paris."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Clifford, Zachary Alan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-02-23T15:03:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-02-23T15:03:18Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2009"]},{"key":"dc:date.issued","label":"Date","values":["2009"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["702680855"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/61313"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0ac6ffc5-08ba-4f9f-99a1-a8d592b68e0b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>An analog and digital data acquisition system for Non-Intrusive Load Monitoring</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Clifford, Zachary Alan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>Non-Intrusive Load Monitoring (NILM) is a method for characterizing and monitoring discrete loads connected to a power distribution system. This can include a ship, a car, or a utility distribution system. The entire concept is predicated on having access to digital samples of the current and voltage signals at the distribution point. This thesis presents a analog to digital converter for this task and a new low-power inductive current sensor for deployment in a standard circuit breaker box. The current sensor uses discrete JFET devices to passively transmit data inductively through the steel door of the circuit breaker.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 327-328)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Non-Intrusive Load Monitoring (NILM) is a method for characterizing and monitoring discrete loads connected to a power distribution system. This can include a ship, a car, or a utility distribution system. The entire concept is predicated on having access to digital samples of the current and voltage signals at the distribution point. This thesis presents a analog to digital converter for this task and a new low-power inductive current sensor for deployment in a standard circuit breaker box. The current sensor uses discrete JFET devices to passively transmit data inductively through the steel door of the circuit breaker."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Zachary Alan Clifford."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["328 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["An analog and digital data acquisition system for Non-Intrusive Load Monitoring"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0ac6ffc5-08ba-4f9f-99a1-a8d592b68e0b\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>An analog and digital data acquisition system for Non-Intrusive Load Monitoring</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2009</PublicationDate> <Authors> <Author> <DisplayName>Clifford, Zachary Alan</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>Non-Intrusive Load Monitoring (NILM) is a method for characterizing and monitoring discrete loads connected to a power distribution system. This can include a ship, a car, or a utility distribution system. The entire concept is predicated on having access to digital samples of the current and voltage signals at the distribution point. This thesis presents a analog to digital converter for this task and a new low-power inductive current sensor for deployment in a standard circuit breaker box. The current sensor uses discrete JFET devices to passively transmit data inductively through the steel door of the circuit breaker.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Steven B. Leeb, John Cooley and James Paris."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science."],"dc:creator":["Clifford, Zachary Alan"],"dc:date.accessioned":["2011-02-23T15:03:18Z"],"dc:date.available":["2011-02-23T15:03:18Z"],"dc:date.copyright":["2009"],"dc:date.issued":["2009"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 2009.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 327-328)."],"dc:description.abstract":["Non-Intrusive Load Monitoring (NILM) is a method for characterizing and monitoring discrete loads connected to a power distribution system. This can include a ship, a car, or a utility distribution system. The entire concept is predicated on having access to digital samples of the current and voltage signals at the distribution point. This thesis presents a analog to digital converter for this task and a new low-power inductive current sensor for deployment in a standard circuit breaker box. The current sensor uses discrete JFET devices to passively transmit data inductively through the steel door of the circuit breaker."],"dc:description.degree":["M.Eng."],"dc:description.statementofresponsibility":["by Zachary Alan Clifford."],"dc:format.extent":["328 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["702680855"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/61313"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["An analog and digital data acquisition system for Non-Intrusive Load Monitoring"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T03:17:24Z"}