{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/67609"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/67609","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Blind transmembrane puncture access : design and development of a novel laparoscopic trocar and blade retraction mechanism","abstract":"Blind puncture access procedures are frequent in medicine but can lead to complications due to over-puncture. When tissue membranes yield under applied stress, the device suddenly accelerates forward into the patient. Clinical background for puncture access procedures and specifically trocar insertion during laparoscopic surgery is presented. A design method is outlined and applied, with functional requirements defined and strategies and concepts detailed. The chosen mechanism concept is developed through geometric analysis. A cost-effective flexure-based mechanism is proposed as an improvement, and flexure mechanics analysis is performed. Flexure samples were manufactured and tested to validate theoretical work and fabrication technique. Prototypes were constructed, revealing the need for further design for assembly and flexure design considerations. Potential solutions are proposed and future steps outlined. The proposed device has the potential to improve safety during blind puncture access procedures by actively opposing forward acceleration of the device upon break-through thus reducing over-puncture incidents.","abstract_html":"Blind puncture access procedures are frequent in medicine but can lead to complications due to over-puncture. When tissue membranes yield under applied stress, the device suddenly accelerates forward into the patient. Clinical background for puncture access procedures and specifically trocar insertion during laparoscopic surgery is presented. A design method is outlined and applied, with functional requirements defined and strategies and concepts detailed. The chosen mechanism concept is developed through geometric analysis. A cost-effective flexure-based mechanism is proposed as an improvement, and flexure mechanics analysis is performed. Flexure samples were manufactured and tested to validate theoretical work and fabrication technique. Prototypes were constructed, revealing the need for further design for assembly and flexure design considerations. Potential solutions are proposed and future steps outlined. The proposed device has the potential to improve safety during blind puncture access procedures by actively opposing forward acceleration of the device upon break-through thus reducing over-puncture incidents.","abstract_has_math":false,"creators":["Begg, Nikolai David Michael"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Alexander H. Slocum."],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011","date_published":"2011","updated_at":"2026-11-27T04:18:01Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["765336427"],"render_values":[{"text":"765336427","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/67609","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/67609","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F67609","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F67609","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Alexander H. Slocum."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Begg, Nikolai David Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2011-12-09T21:31:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2011-12-09T21:31:56Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2011"]},{"key":"dc:date.issued","label":"Date","values":["2011"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["765336427"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/67609"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0b9a2e74-f04f-417c-ac08-f29b507341e3\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Blind transmembrane puncture access : design and development of a novel laparoscopic trocar and blade retraction mechanism</Title> <Subtitle>Laparoscopic trocar and blade retraction mechanism</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011</PublicationDate> <Authors> <Author> <DisplayName>Begg, Nikolai David Michael</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Blind puncture access procedures are frequent in medicine but can lead to complications due to over-puncture. When tissue membranes yield under applied stress, the device suddenly accelerates forward into the patient. Clinical background for puncture access procedures and specifically trocar insertion during laparoscopic surgery is presented. A design method is outlined and applied, with functional requirements defined and strategies and concepts detailed. The chosen mechanism concept is developed through geometric analysis. A cost-effective flexure-based mechanism is proposed as an improvement, and flexure mechanics analysis is performed. Flexure samples were manufactured and tested to validate theoretical work and fabrication technique. Prototypes were constructed, revealing the need for further design for assembly and flexure design considerations. Potential solutions are proposed and future steps outlined. The proposed device has the potential to improve safety during blind puncture access procedures by actively opposing forward acceleration of the device upon break-through thus reducing over-puncture incidents.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 77-78)."]},{"key":"dc:description.abstract","label":"Abstract","values":["Blind puncture access procedures are frequent in medicine but can lead to complications due to over-puncture. When tissue membranes yield under applied stress, the device suddenly accelerates forward into the patient. Clinical background for puncture access procedures and specifically trocar insertion during laparoscopic surgery is presented. A design method is outlined and applied, with functional requirements defined and strategies and concepts detailed. The chosen mechanism concept is developed through geometric analysis. A cost-effective flexure-based mechanism is proposed as an improvement, and flexure mechanics analysis is performed. Flexure samples were manufactured and tested to validate theoretical work and fabrication technique. Prototypes were constructed, revealing the need for further design for assembly and flexure design considerations. Potential solutions are proposed and future steps outlined. The proposed device has the potential to improve safety during blind puncture access procedures by actively opposing forward acceleration of the device upon break-through thus reducing over-puncture incidents."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Nikolai David Michael Begg."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["102 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Blind transmembrane puncture access : design and development of a novel laparoscopic trocar and blade retraction mechanism"]},{"key":"dc:title.alternative","label":"Alternative Title","values":["Laparoscopic trocar and blade retraction mechanism"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"0b9a2e74-f04f-417c-ac08-f29b507341e3\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Blind transmembrane puncture access : design and development of a novel laparoscopic trocar and blade retraction mechanism</Title> <Subtitle>Laparoscopic trocar and blade retraction mechanism</Subtitle> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2011</PublicationDate> <Authors> <Author> <DisplayName>Begg, Nikolai David Michael</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>Blind puncture access procedures are frequent in medicine but can lead to complications due to over-puncture. When tissue membranes yield under applied stress, the device suddenly accelerates forward into the patient. Clinical background for puncture access procedures and specifically trocar insertion during laparoscopic surgery is presented. A design method is outlined and applied, with functional requirements defined and strategies and concepts detailed. The chosen mechanism concept is developed through geometric analysis. A cost-effective flexure-based mechanism is proposed as an improvement, and flexure mechanics analysis is performed. Flexure samples were manufactured and tested to validate theoretical work and fabrication technique. Prototypes were constructed, revealing the need for further design for assembly and flexure design considerations. Potential solutions are proposed and future steps outlined. The proposed device has the potential to improve safety during blind puncture access procedures by actively opposing forward acceleration of the device upon break-through thus reducing over-puncture incidents.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Alexander H. Slocum."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Mechanical Engineering."],"dc:creator":["Begg, Nikolai David Michael"],"dc:date.accessioned":["2011-12-09T21:31:56Z"],"dc:date.available":["2011-12-09T21:31:56Z"],"dc:date.copyright":["2011"],"dc:date.issued":["2011"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2011.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 77-78)."],"dc:description.abstract":["Blind puncture access procedures are frequent in medicine but can lead to complications due to over-puncture. When tissue membranes yield under applied stress, the device suddenly accelerates forward into the patient. Clinical background for puncture access procedures and specifically trocar insertion during laparoscopic surgery is presented. A design method is outlined and applied, with functional requirements defined and strategies and concepts detailed. The chosen mechanism concept is developed through geometric analysis. A cost-effective flexure-based mechanism is proposed as an improvement, and flexure mechanics analysis is performed. Flexure samples were manufactured and tested to validate theoretical work and fabrication technique. Prototypes were constructed, revealing the need for further design for assembly and flexure design considerations. Potential solutions are proposed and future steps outlined. The proposed device has the potential to improve safety during blind puncture access procedures by actively opposing forward acceleration of the device upon break-through thus reducing over-puncture incidents."],"dc:description.degree":["S.M."],"dc:description.statementofresponsibility":["by Nikolai David Michael Begg."],"dc:format.extent":["102 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["765336427"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/67609"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["Blind transmembrane puncture access : design and development of a novel laparoscopic trocar and blade retraction mechanism"],"dc:title.alternative":["Laparoscopic trocar and blade retraction mechanism"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T04:18:01Z"}