{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/78513"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/78513","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Simulated liquid argon interactions with neutrons","abstract":"The GEANT4 physics simulation program is known to have errors in how hadronic interactions are implemented. This has the potential to cause errors in the Monte Carlos used to determine the expected neutron backgrounds in the MiniCLEAN single phase liquid argon WIMP detector. Elastic and inelastic collisions between neutrons and argon nuclei as well as neutron captures were simulated independently in order to characterize the accuracy of the implementation by GEANT4.9.3.pOl and GEANT4.9.5. The effective cross sections, angular distributions, photons, decay schemes, energy conservation, and momentum conservation were determined through analysis of the neutron tracks created by GEANT4. A large proportion of the interactions behave as expected, however energy and momentum are not conserved by varying degrees of severity with some GEANT4.9.3.pOl inelastic collisions resulting in over twice the correct amount of energy.","abstract_html":"The GEANT4 physics simulation program is known to have errors in how hadronic interactions are implemented. This has the potential to cause errors in the Monte Carlos used to determine the expected neutron backgrounds in the MiniCLEAN single phase liquid argon WIMP detector. Elastic and inelastic collisions between neutrons and argon nuclei as well as neutron captures were simulated independently in order to characterize the accuracy of the implementation by GEANT4.9.3.pOl and GEANT4.9.5. The effective cross sections, angular distributions, photons, decay schemes, energy conservation, and momentum conservation were determined through analysis of the neutron tracks created by GEANT4. A large proportion of the interactions behave as expected, however energy and momentum are not conserved by varying degrees of severity with some GEANT4.9.3.pOl inelastic collisions resulting in over twice the correct amount of energy.","abstract_has_math":false,"creators":["Harrington, Kathleen M"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Simulated Liquid Argon Interactions and Kimberly J. Palladino."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012","date_published":"2012","updated_at":"2026-11-27T23:31:27Z","subjects":["Physics."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["836815338"],"render_values":[{"text":"836815338","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/78513","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/78513","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F78513","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F78513","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Simulated Liquid Argon Interactions and Kimberly J. Palladino."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Physics."]},{"key":"dc:creator","label":"Author","values":["Harrington, Kathleen M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-12T19:31:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-04-12T19:31:21Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2012"]},{"key":"dc:date.issued","label":"Date","values":["2012"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["836815338"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/78513"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"51c3c965-dead-469d-bff8-6c787e54709c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Simulated liquid argon interactions with neutrons</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2012</PublicationDate> <Authors> <Author> <DisplayName>Harrington, Kathleen M</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>The GEANT4 physics simulation program is known to have errors in how hadronic interactions are implemented. This has the potential to cause errors in the Monte Carlos used to determine the expected neutron backgrounds in the MiniCLEAN single phase liquid argon WIMP detector. Elastic and inelastic collisions between neutrons and argon nuclei as well as neutron captures were simulated independently in order to characterize the accuracy of the implementation by GEANT4.9.3.pOl and GEANT4.9.5. The effective cross sections, angular distributions, photons, decay schemes, energy conservation, and momentum conservation were determined through analysis of the neutron tracks created by GEANT4. A large proportion of the interactions behave as expected, however energy and momentum are not conserved by varying degrees of severity with some GEANT4.9.3.pOl inelastic collisions resulting in over twice the correct amount of energy.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 77-78)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The GEANT4 physics simulation program is known to have errors in how hadronic interactions are implemented. This has the potential to cause errors in the Monte Carlos used to determine the expected neutron backgrounds in the MiniCLEAN single phase liquid argon WIMP detector. Elastic and inelastic collisions between neutrons and argon nuclei as well as neutron captures were simulated independently in order to characterize the accuracy of the implementation by GEANT4.9.3.pOl and GEANT4.9.5. The effective cross sections, angular distributions, photons, decay schemes, energy conservation, and momentum conservation were determined through analysis of the neutron tracks created by GEANT4. A large proportion of the interactions behave as expected, however energy and momentum are not conserved by varying degrees of severity with some GEANT4.9.3.pOl inelastic collisions resulting in over twice the correct amount of energy."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Kathleen M. Harrington."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["78 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Simulated liquid argon interactions with neutrons"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"51c3c965-dead-469d-bff8-6c787e54709c\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Simulated liquid argon interactions with neutrons</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2012</PublicationDate> <Authors> <Author> <DisplayName>Harrington, Kathleen M</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>The GEANT4 physics simulation program is known to have errors in how hadronic interactions are implemented. This has the potential to cause errors in the Monte Carlos used to determine the expected neutron backgrounds in the MiniCLEAN single phase liquid argon WIMP detector. Elastic and inelastic collisions between neutrons and argon nuclei as well as neutron captures were simulated independently in order to characterize the accuracy of the implementation by GEANT4.9.3.pOl and GEANT4.9.5. The effective cross sections, angular distributions, photons, decay schemes, energy conservation, and momentum conservation were determined through analysis of the neutron tracks created by GEANT4. A large proportion of the interactions behave as expected, however energy and momentum are not conserved by varying degrees of severity with some GEANT4.9.3.pOl inelastic collisions resulting in over twice the correct amount of energy.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Simulated Liquid Argon Interactions and Kimberly J. Palladino."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Physics."],"dc:creator":["Harrington, Kathleen M"],"dc:date.accessioned":["2013-04-12T19:31:21Z"],"dc:date.available":["2013-04-12T19:31:21Z"],"dc:date.copyright":["2012"],"dc:date.issued":["2012"],"dc:description":["Thesis (S.B.)--Massachusetts Institute of Technology, Dept. of Physics, 2012.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 77-78)."],"dc:description.abstract":["The GEANT4 physics simulation program is known to have errors in how hadronic interactions are implemented. This has the potential to cause errors in the Monte Carlos used to determine the expected neutron backgrounds in the MiniCLEAN single phase liquid argon WIMP detector. Elastic and inelastic collisions between neutrons and argon nuclei as well as neutron captures were simulated independently in order to characterize the accuracy of the implementation by GEANT4.9.3.pOl and GEANT4.9.5. The effective cross sections, angular distributions, photons, decay schemes, energy conservation, and momentum conservation were determined through analysis of the neutron tracks created by GEANT4. A large proportion of the interactions behave as expected, however energy and momentum are not conserved by varying degrees of severity with some GEANT4.9.3.pOl inelastic collisions resulting in over twice the correct amount of energy."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Kathleen M. Harrington."],"dc:format.extent":["78 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["836815338"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/78513"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["Simulated liquid argon interactions with neutrons"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T23:31:27Z"}