{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/81136"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/81136","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"The development of a thin-film rollforming process for pharmaceutical continuous manufacturing","abstract":"In this thesis, a continuous rollforming process for the folding of thin-films was proposed and studied as a key step in the continuous manufacturing of pharmaceutical tablets. HPMC and PEG based polymeric thin-films were considered for this application. An experimental apparatus was designed and developed to test the folding of thin-films. The experimental apparatus was designed in a modular fashion to facilitate testing of various process parameters. Analysis was carried out for the folding operations, based on which two folding strategies were proposed - (i) without scoring and (ii) with scoring. The first strategy relies on elastic deformation of the thin-films, whereas the later depends on localized, plastic deformation caused by the scoring geometry. From the experiments on folding we identified three regimes of process operation namely: insufficient scoring, appropriate scoring, and excessive scoring. The implications of different levels of scoring were observed and understood carefully for the scoring and folding operation. Practical guidelines were developed for carrying out folding successfully and the scope of future work was discussed.","abstract_html":"In this thesis, a continuous rollforming process for the folding of thin-films was proposed and studied as a key step in the continuous manufacturing of pharmaceutical tablets. HPMC and PEG based polymeric thin-films were considered for this application. An experimental apparatus was designed and developed to test the folding of thin-films. The experimental apparatus was designed in a modular fashion to facilitate testing of various process parameters. Analysis was carried out for the folding operations, based on which two folding strategies were proposed - (i) without scoring and (ii) with scoring. The first strategy relies on elastic deformation of the thin-films, whereas the later depends on localized, plastic deformation caused by the scoring geometry. From the experiments on folding we identified three regimes of process operation namely: insufficient scoring, appropriate scoring, and excessive scoring. The implications of different levels of scoring were observed and understood carefully for the scoring and folding operation. Practical guidelines were developed for carrying out folding successfully and the scope of future work was discussed.","abstract_has_math":false,"creators":["Slaughter, Ryan (Ryan R.)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Jung-Hoon Chun."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-27T07:24:42Z","subjects":["Mechanical Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["858281394"],"render_values":[{"text":"858281394","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/81136","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/81136","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F81136","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F81136","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Jung-Hoon Chun."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Mechanical Engineering."]},{"key":"dc:creator","label":"Author","values":["Slaughter, Ryan (Ryan R.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-09-24T19:45:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-09-24T19:45:12Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["858281394"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/81136"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"418dad00-661c-4677-bb0d-38a1cc26a78a\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>The development of a thin-film rollforming process for pharmaceutical continuous manufacturing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013</PublicationDate> <Authors> <Author> <DisplayName>Slaughter, Ryan (Ryan R.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>In this thesis, a continuous rollforming process for the folding of thin-films was proposed and studied as a key step in the continuous manufacturing of pharmaceutical tablets. HPMC and PEG based polymeric thin-films were considered for this application. An experimental apparatus was designed and developed to test the folding of thin-films. The experimental apparatus was designed in a modular fashion to facilitate testing of various process parameters. Analysis was carried out for the folding operations, based on which two folding strategies were proposed - (i) without scoring and (ii) with scoring. The first strategy relies on elastic deformation of the thin-films, whereas the later depends on localized, plastic deformation caused by the scoring geometry. From the experiments on folding we identified three regimes of process operation namely: insufficient scoring, appropriate scoring, and excessive scoring. The implications of different levels of scoring were observed and understood carefully for the scoring and folding operation. Practical guidelines were developed for carrying out folding successfully and the scope of future work was discussed.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2013.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 51-53)."]},{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, a continuous rollforming process for the folding of thin-films was proposed and studied as a key step in the continuous manufacturing of pharmaceutical tablets. HPMC and PEG based polymeric thin-films were considered for this application. An experimental apparatus was designed and developed to test the folding of thin-films. The experimental apparatus was designed in a modular fashion to facilitate testing of various process parameters. Analysis was carried out for the folding operations, based on which two folding strategies were proposed - (i) without scoring and (ii) with scoring. The first strategy relies on elastic deformation of the thin-films, whereas the later depends on localized, plastic deformation caused by the scoring geometry. From the experiments on folding we identified three regimes of process operation namely: insufficient scoring, appropriate scoring, and excessive scoring. The implications of different levels of scoring were observed and understood carefully for the scoring and folding operation. Practical guidelines were developed for carrying out folding successfully and the scope of future work was discussed."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.M."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Ryan Slaughter."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["53 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The development of a thin-film rollforming process for pharmaceutical continuous manufacturing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"418dad00-661c-4677-bb0d-38a1cc26a78a\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>The development of a thin-film rollforming process for pharmaceutical continuous manufacturing</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013</PublicationDate> <Authors> <Author> <DisplayName>Slaughter, Ryan (Ryan R.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Mechanical Engineering.</Keyword> <Abstract>In this thesis, a continuous rollforming process for the folding of thin-films was proposed and studied as a key step in the continuous manufacturing of pharmaceutical tablets. HPMC and PEG based polymeric thin-films were considered for this application. An experimental apparatus was designed and developed to test the folding of thin-films. The experimental apparatus was designed in a modular fashion to facilitate testing of various process parameters. Analysis was carried out for the folding operations, based on which two folding strategies were proposed - (i) without scoring and (ii) with scoring. The first strategy relies on elastic deformation of the thin-films, whereas the later depends on localized, plastic deformation caused by the scoring geometry. From the experiments on folding we identified three regimes of process operation namely: insufficient scoring, appropriate scoring, and excessive scoring. The implications of different levels of scoring were observed and understood carefully for the scoring and folding operation. Practical guidelines were developed for carrying out folding successfully and the scope of future work was discussed.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Jung-Hoon Chun."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Mechanical Engineering."],"dc:creator":["Slaughter, Ryan (Ryan R.)"],"dc:date.accessioned":["2013-09-24T19:45:12Z"],"dc:date.available":["2013-09-24T19:45:12Z"],"dc:date.copyright":["2013"],"dc:date.issued":["2013"],"dc:description":["Thesis (S.M.)--Massachusetts Institute of Technology, Dept. of Mechanical Engineering, 2013.","Cataloged from PDF version of thesis.","Includes bibliographical references (p. 51-53)."],"dc:description.abstract":["In this thesis, a continuous rollforming process for the folding of thin-films was proposed and studied as a key step in the continuous manufacturing of pharmaceutical tablets. HPMC and PEG based polymeric thin-films were considered for this application. An experimental apparatus was designed and developed to test the folding of thin-films. The experimental apparatus was designed in a modular fashion to facilitate testing of various process parameters. Analysis was carried out for the folding operations, based on which two folding strategies were proposed - (i) without scoring and (ii) with scoring. The first strategy relies on elastic deformation of the thin-films, whereas the later depends on localized, plastic deformation caused by the scoring geometry. From the experiments on folding we identified three regimes of process operation namely: insufficient scoring, appropriate scoring, and excessive scoring. The implications of different levels of scoring were observed and understood carefully for the scoring and folding operation. Practical guidelines were developed for carrying out folding successfully and the scope of future work was discussed."],"dc:description.degree":["S.M."],"dc:description.statementofresponsibility":["by Ryan Slaughter."],"dc:format.extent":["53 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["858281394"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/81136"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Mechanical Engineering."],"dc:title":["The development of a thin-film rollforming process for pharmaceutical continuous manufacturing"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T07:24:42Z"}