{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/82717"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/82717","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"The dynamic behavior of the Basilica of San Francesco of Assisi","abstract":"During the 1997 Umbria-Marche earthquake, two of the vaults of the Basilica of San Francesco in Assisi collapsed as a result of an 8.5 Mercalli-scale magnitude earthquake. The structure had endured stronger earthquakes for centuries before this earthquake, and there were likely many reasons for the collapse, such as damages accumulated from previous earthquakes. However, one of the factors that may have lead to the collapse is the modifications made to the structure over its lifetime, which could have made the basilica more susceptible to the 1997 earthquake. The basilica's roof has been subjected to three major alterations in its 760 year life. Each alteration changed the weight and stiffness properties of the roof and global dynamic behavior of the basilica. In this thesis, simple analytical models are employed to show trends in the structure's seismic response given the changes in stiffness and mass of the roof over the centuries. The findings of the analytical model suggest that the roof interventions have had the eect of decreasing the structure's fundamental period, and therefore, attracting more seismic forces to existing structural elements. The findings of this study are meant to educate preservation engineers for similar interventions in the future as well as address present day public safety issues regarding retrofitted historic structures. Keywords Basilica of San Francesco of Assisi, Historic Masonry Structures, Monumental Structures, Seismic Vulnerability, Seismic Retrofitting","abstract_html":"During the 1997 Umbria-Marche earthquake, two of the vaults of the Basilica of San Francesco in Assisi collapsed as a result of an 8.5 Mercalli-scale magnitude earthquake. The structure had endured stronger earthquakes for centuries before this earthquake, and there were likely many reasons for the collapse, such as damages accumulated from previous earthquakes. However, one of the factors that may have lead to the collapse is the modifications made to the structure over its lifetime, which could have made the basilica more susceptible to the 1997 earthquake. The basilica&#x27;s roof has been subjected to three major alterations in its 760 year life. Each alteration changed the weight and stiffness properties of the roof and global dynamic behavior of the basilica. In this thesis, simple analytical models are employed to show trends in the structure&#x27;s seismic response given the changes in stiffness and mass of the roof over the centuries. The findings of the analytical model suggest that the roof interventions have had the eect of decreasing the structure&#x27;s fundamental period, and therefore, attracting more seismic forces to existing structural elements. The findings of this study are meant to educate preservation engineers for similar interventions in the future as well as address present day public safety issues regarding retrofitted historic structures. Keywords Basilica of San Francesco of Assisi, Historic Masonry Structures, Monumental Structures, Seismic Vulnerability, Seismic Retrofitting","abstract_has_math":false,"creators":["Piermarini, Emidio (Emidio Antonio)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["John Ochsendorf."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-27T06:23:18Z","subjects":["Civil and Environmental Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["862820432"],"render_values":[{"text":"862820432","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/82717","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/82717","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F82717","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F82717","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["John Ochsendorf."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Civil and Environmental Engineering."]},{"key":"dc:creator","label":"Author","values":["Piermarini, Emidio (Emidio Antonio)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-12-06T19:51:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-12-06T19:51:38Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2013"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil and Environmental Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["862820432"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/82717"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"387a1ecc-6574-4926-a134-63639d161562\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>The dynamic behavior of the Basilica of San Francesco of Assisi</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013</PublicationDate> <Authors> <Author> <DisplayName>Piermarini, Emidio (Emidio Antonio)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Civil and Environmental Engineering.</Keyword> <Abstract>During the 1997 Umbria-Marche earthquake, two of the vaults of the Basilica of San Francesco in Assisi collapsed as a result of an 8.5 Mercalli-scale magnitude earthquake. The structure had endured stronger earthquakes for centuries before this earthquake, and there were likely many reasons for the collapse, such as damages accumulated from previous earthquakes. However, one of the factors that may have lead to the collapse is the modifications made to the structure over its lifetime, which could have made the basilica more susceptible to the 1997 earthquake. The basilica's roof has been subjected to three major alterations in its 760 year life. Each alteration changed the weight and stiffness properties of the roof and global dynamic behavior of the basilica. In this thesis, simple analytical models are employed to show trends in the structure's seismic response given the changes in stiffness and mass of the roof over the centuries. The findings of the analytical model suggest that the roof interventions have had the eect of decreasing the structure's fundamental period, and therefore, attracting more seismic forces to existing structural elements. The findings of this study are meant to educate preservation engineers for similar interventions in the future as well as address present day public safety issues regarding retrofitted historic structures. Keywords Basilica of San Francesco of Assisi, Historic Masonry Structures, Monumental Structures, Seismic Vulnerability, Seismic Retrofitting</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2013.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (p. 61-62)."]},{"key":"dc:description.abstract","label":"Abstract","values":["During the 1997 Umbria-Marche earthquake, two of the vaults of the Basilica of San Francesco in Assisi collapsed as a result of an 8.5 Mercalli-scale magnitude earthquake. The structure had endured stronger earthquakes for centuries before this earthquake, and there were likely many reasons for the collapse, such as damages accumulated from previous earthquakes. However, one of the factors that may have lead to the collapse is the modifications made to the structure over its lifetime, which could have made the basilica more susceptible to the 1997 earthquake. The basilica's roof has been subjected to three major alterations in its 760 year life. Each alteration changed the weight and stiffness properties of the roof and global dynamic behavior of the basilica. In this thesis, simple analytical models are employed to show trends in the structure's seismic response given the changes in stiffness and mass of the roof over the centuries. The findings of the analytical model suggest that the roof interventions have had the eect of decreasing the structure's fundamental period, and therefore, attracting more seismic forces to existing structural elements. The findings of this study are meant to educate preservation engineers for similar interventions in the future as well as address present day public safety issues regarding retrofitted historic structures. Keywords Basilica of San Francesco of Assisi, Historic Masonry Structures, Monumental Structures, Seismic Vulnerability, Seismic Retrofitting"]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Emidio Piermarini."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["68 p."]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The dynamic behavior of the Basilica of San Francesco of Assisi"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"387a1ecc-6574-4926-a134-63639d161562\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>The dynamic behavior of the Basilica of San Francesco of Assisi</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013</PublicationDate> <Authors> <Author> <DisplayName>Piermarini, Emidio (Emidio Antonio)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Civil and Environmental Engineering.</Keyword> <Abstract>During the 1997 Umbria-Marche earthquake, two of the vaults of the Basilica of San Francesco in Assisi collapsed as a result of an 8.5 Mercalli-scale magnitude earthquake. The structure had endured stronger earthquakes for centuries before this earthquake, and there were likely many reasons for the collapse, such as damages accumulated from previous earthquakes. However, one of the factors that may have lead to the collapse is the modifications made to the structure over its lifetime, which could have made the basilica more susceptible to the 1997 earthquake. The basilica's roof has been subjected to three major alterations in its 760 year life. Each alteration changed the weight and stiffness properties of the roof and global dynamic behavior of the basilica. In this thesis, simple analytical models are employed to show trends in the structure's seismic response given the changes in stiffness and mass of the roof over the centuries. The findings of the analytical model suggest that the roof interventions have had the eect of decreasing the structure's fundamental period, and therefore, attracting more seismic forces to existing structural elements. The findings of this study are meant to educate preservation engineers for similar interventions in the future as well as address present day public safety issues regarding retrofitted historic structures. Keywords Basilica of San Francesco of Assisi, Historic Masonry Structures, Monumental Structures, Seismic Vulnerability, Seismic Retrofitting</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["John Ochsendorf."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Civil and Environmental Engineering."],"dc:creator":["Piermarini, Emidio (Emidio Antonio)"],"dc:date.accessioned":["2013-12-06T19:51:38Z"],"dc:date.available":["2013-12-06T19:51:38Z"],"dc:date.copyright":["2013"],"dc:date.issued":["2013"],"dc:description":["Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2013.","This electronic version was submitted by the student author. The certified thesis is available in the Institute Archives and Special Collections.","Cataloged from student-submitted PDF version of thesis.","Includes bibliographical references (p. 61-62)."],"dc:description.abstract":["During the 1997 Umbria-Marche earthquake, two of the vaults of the Basilica of San Francesco in Assisi collapsed as a result of an 8.5 Mercalli-scale magnitude earthquake. The structure had endured stronger earthquakes for centuries before this earthquake, and there were likely many reasons for the collapse, such as damages accumulated from previous earthquakes. However, one of the factors that may have lead to the collapse is the modifications made to the structure over its lifetime, which could have made the basilica more susceptible to the 1997 earthquake. The basilica's roof has been subjected to three major alterations in its 760 year life. Each alteration changed the weight and stiffness properties of the roof and global dynamic behavior of the basilica. In this thesis, simple analytical models are employed to show trends in the structure's seismic response given the changes in stiffness and mass of the roof over the centuries. The findings of the analytical model suggest that the roof interventions have had the eect of decreasing the structure's fundamental period, and therefore, attracting more seismic forces to existing structural elements. The findings of this study are meant to educate preservation engineers for similar interventions in the future as well as address present day public safety issues regarding retrofitted historic structures. Keywords Basilica of San Francesco of Assisi, Historic Masonry Structures, Monumental Structures, Seismic Vulnerability, Seismic Retrofitting"],"dc:description.degree":["M.Eng."],"dc:description.statementofresponsibility":["by Emidio Piermarini."],"dc:format.extent":["68 p."],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["862820432"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/82717"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Civil and Environmental Engineering."],"dc:title":["The dynamic behavior of the Basilica of San Francesco of Assisi"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T06:23:18Z"}