{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/8292"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/8292","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"A precision millimeter-wave measurement of the Rydberg frequency","abstract":"The Rydberg frequency, cR[infinity], sets the frequency scale for the spectrum of hydrogen atoms. From a frequency measurement of one transition in hydrogen, cR[infinity] can be extracted and the frequency of any other transition can be predicted, given that the reduced-mass, relativistic, QED, and proton structure corrections can be computed to the desired accuracy. Recent advances in optical frequency techniques applied to transitions involving low-lying states of hydrogen have decreased the uncertainty in cR[infinity], to 7.6 x 10⁻¹². This thesis presents our measurement of cR[infinity] using millimeter-wave transitions between high-lying \"circular Rydberg\" states of atomic hydrogen with a principle quantum number, n, between 27 and 30. This measurement provides an independent check, in a different regime, of the optical measurements. Our measurement, cR[infinity] = 3 289 841 960 306(69) kHz with an uncertainty of 2.1 x 10⁻¹¹, is consistent with the CODATA 98 recommended value.","abstract_html":"The Rydberg frequency, cR[infinity], sets the frequency scale for the spectrum of hydrogen atoms. From a frequency measurement of one transition in hydrogen, cR[infinity] can be extracted and the frequency of any other transition can be predicted, given that the reduced-mass, relativistic, QED, and proton structure corrections can be computed to the desired accuracy. Recent advances in optical frequency techniques applied to transitions involving low-lying states of hydrogen have decreased the uncertainty in cR[infinity], to 7.6 x 10⁻¹². This thesis presents our measurement of cR[infinity] using millimeter-wave transitions between high-lying &quot;circular Rydberg&quot; states of atomic hydrogen with a principle quantum number, n, between 27 and 30. This measurement provides an independent check, in a different regime, of the optical measurements. Our measurement, cR[infinity] = 3 289 841 960 306(69) kHz with an uncertainty of 2.1 x 10⁻¹¹, is consistent with the CODATA 98 recommended value.","abstract_has_math":false,"creators":["De Vries, Joel Christopher, 1971-"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Daniel Kleppner."],"committee_chairs":[],"committee_members":[],"year":2002,"date_issued":"2002","date_published":"2002","updated_at":"2026-11-27T06:23:30Z","subjects":["Physics."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["50421471"],"render_values":[{"text":"50421471","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/8292","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/8292","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F8292","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F8292","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Daniel Kleppner."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Dept. of Physics."]},{"key":"dc:creator","label":"Author","values":["De Vries, Joel Christopher, 1971-"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2005-08-23T18:56:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2005-08-23T18:56:37Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2001"]},{"key":"dc:date.issued","label":"Date","values":["2002"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["50421471"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/8292"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3af371c0-add0-49f1-8d79-4929abc91eea\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>A precision millimeter-wave measurement of the Rydberg frequency</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2002</PublicationDate> <Authors> <Author> <DisplayName>De Vries, Joel Christopher, 1971-</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>The Rydberg frequency, cR[infinity], sets the frequency scale for the spectrum of hydrogen atoms. From a frequency measurement of one transition in hydrogen, cR[infinity] can be extracted and the frequency of any other transition can be predicted, given that the reduced-mass, relativistic, QED, and proton structure corrections can be computed to the desired accuracy. Recent advances in optical frequency techniques applied to transitions involving low-lying states of hydrogen have decreased the uncertainty in cR[infinity], to 7.6 x 10⁻¹². This thesis presents our measurement of cR[infinity] using millimeter-wave transitions between high-lying \"circular Rydberg\" states of atomic hydrogen with a principle quantum number, n, between 27 and 30. This measurement provides an independent check, in a different regime, of the optical measurements. Our measurement, cR[infinity] = 3 289 841 960 306(69) kHz with an uncertainty of 2.1 x 10⁻¹¹, is consistent with the CODATA 98 recommended value.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Physics, February 2002.","Includes bibliographical references (p. 161-163)."]},{"key":"dc:description.abstract","label":"Abstract","values":["The Rydberg frequency, cR[infinity], sets the frequency scale for the spectrum of hydrogen atoms. From a frequency measurement of one transition in hydrogen, cR[infinity] can be extracted and the frequency of any other transition can be predicted, given that the reduced-mass, relativistic, QED, and proton structure corrections can be computed to the desired accuracy. Recent advances in optical frequency techniques applied to transitions involving low-lying states of hydrogen have decreased the uncertainty in cR[infinity], to 7.6 x 10⁻¹². This thesis presents our measurement of cR[infinity] using millimeter-wave transitions between high-lying \"circular Rydberg\" states of atomic hydrogen with a principle quantum number, n, between 27 and 30. This measurement provides an independent check, in a different regime, of the optical measurements. Our measurement, cR[infinity] = 3 289 841 960 306(69) kHz with an uncertainty of 2.1 x 10⁻¹¹, is consistent with the CODATA 98 recommended value."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph.D."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Joel Christopher De Vries."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["166 p.","11163100 bytes","11162860 bytes"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A precision millimeter-wave measurement of the Rydberg frequency"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3af371c0-add0-49f1-8d79-4929abc91eea\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>A precision millimeter-wave measurement of the Rydberg frequency</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2002</PublicationDate> <Authors> <Author> <DisplayName>De Vries, Joel Christopher, 1971-</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Physics.</Keyword> <Abstract>The Rydberg frequency, cR[infinity], sets the frequency scale for the spectrum of hydrogen atoms. From a frequency measurement of one transition in hydrogen, cR[infinity] can be extracted and the frequency of any other transition can be predicted, given that the reduced-mass, relativistic, QED, and proton structure corrections can be computed to the desired accuracy. Recent advances in optical frequency techniques applied to transitions involving low-lying states of hydrogen have decreased the uncertainty in cR[infinity], to 7.6 x 10⁻¹². This thesis presents our measurement of cR[infinity] using millimeter-wave transitions between high-lying \"circular Rydberg\" states of atomic hydrogen with a principle quantum number, n, between 27 and 30. This measurement provides an independent check, in a different regime, of the optical measurements. Our measurement, cR[infinity] = 3 289 841 960 306(69) kHz with an uncertainty of 2.1 x 10⁻¹¹, is consistent with the CODATA 98 recommended value.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Daniel Kleppner."],"dc:contributor.other":["Massachusetts Institute of Technology. Dept. of Physics."],"dc:creator":["De Vries, Joel Christopher, 1971-"],"dc:date.accessioned":["2005-08-23T18:56:37Z"],"dc:date.available":["2005-08-23T18:56:37Z"],"dc:date.copyright":["2001"],"dc:date.issued":["2002"],"dc:description":["Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Physics, February 2002.","Includes bibliographical references (p. 161-163)."],"dc:description.abstract":["The Rydberg frequency, cR[infinity], sets the frequency scale for the spectrum of hydrogen atoms. From a frequency measurement of one transition in hydrogen, cR[infinity] can be extracted and the frequency of any other transition can be predicted, given that the reduced-mass, relativistic, QED, and proton structure corrections can be computed to the desired accuracy. Recent advances in optical frequency techniques applied to transitions involving low-lying states of hydrogen have decreased the uncertainty in cR[infinity], to 7.6 x 10⁻¹². This thesis presents our measurement of cR[infinity] using millimeter-wave transitions between high-lying \"circular Rydberg\" states of atomic hydrogen with a principle quantum number, n, between 27 and 30. This measurement provides an independent check, in a different regime, of the optical measurements. Our measurement, cR[infinity] = 3 289 841 960 306(69) kHz with an uncertainty of 2.1 x 10⁻¹¹, is consistent with the CODATA 98 recommended value."],"dc:description.degree":["Ph.D."],"dc:description.statementofresponsibility":["by Joel Christopher De Vries."],"dc:format.extent":["166 p.","11163100 bytes","11162860 bytes"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["50421471"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/8292"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Physics."],"dc:title":["A precision millimeter-wave measurement of the Rydberg frequency"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T06:23:30Z"}