{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/85508"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/85508","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Low-cost educational stochastic optical reconstruction microscopy (eSTORM)","abstract":"A stochastic optical reconstruction microscope was built and demonstrated for under $20,000, enabling hands-on learning of single-molecule localization concepts in teaching laboratories. This was accomplished by replacing the most expensive parts of $500,000 commercial instruments, namely the laser, camera, and objective, with lower cost alternatives. Since lower cost also comes with higher noise, we characterized the optical and noise characteristics of the microscope. A new sample protocol, consisting of microspheres labeled with streptavidin-Alexa 647 conjugates, was developed to test the system, compare the image quality of two reconstruction programs (QuickPALM and rapidSTORM), and evaluate trade-offs in camera selection. Finally, by imaging defined actin features in 3T3 cells, the instrument was estimated to have a sub-diffraction resolution between 70 -100 nm.","abstract_html":"A stochastic optical reconstruction microscope was built and demonstrated for under $20,000, enabling hands-on learning of single-molecule localization concepts in teaching laboratories. This was accomplished by replacing the most expensive parts of $500,000 commercial instruments, namely the laser, camera, and objective, with lower cost alternatives. Since lower cost also comes with higher noise, we characterized the optical and noise characteristics of the microscope. A new sample protocol, consisting of microspheres labeled with streptavidin-Alexa 647 conjugates, was developed to test the system, compare the image quality of two reconstruction programs (QuickPALM and rapidSTORM), and evaluate trade-offs in camera selection. Finally, by imaging defined actin features in 3T3 cells, the instrument was estimated to have a sub-diffraction resolution between 70 -100 nm.","abstract_has_math":true,"creators":["Sun, Ranbel F. (Ranbel Field)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Edward S. Boyden."],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013","date_published":"2013","updated_at":"2026-11-27T07:24:40Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["871004481"],"render_values":[{"text":"871004481","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/85508","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/85508","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F85508","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F85508","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Edward S. Boyden."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Sun, Ranbel F. (Ranbel Field)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-06T15:47:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-06T15:47:04Z"]},{"key":"dc:date.issued","label":"Date","values":["2013"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["871004481"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/85508"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"41639513-371a-4556-8f53-d3e56f8f3dff\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Low-cost educational stochastic optical reconstruction microscopy (eSTORM)</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013</PublicationDate> <Authors> <Author> <DisplayName>Sun, Ranbel F. (Ranbel Field)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>A stochastic optical reconstruction microscope was built and demonstrated for under $20,000, enabling hands-on learning of single-molecule localization concepts in teaching laboratories. This was accomplished by replacing the most expensive parts of $500,000 commercial instruments, namely the laser, camera, and objective, with lower cost alternatives. Since lower cost also comes with higher noise, we characterized the optical and noise characteristics of the microscope. A new sample protocol, consisting of microspheres labeled with streptavidin-Alexa 647 conjugates, was developed to test the system, compare the image quality of two reconstruction programs (QuickPALM and rapidSTORM), and evaluate trade-offs in camera selection. Finally, by imaging defined actin features in 3T3 cells, the instrument was estimated to have a sub-diffraction resolution between 70 -100 nm.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, September 2013.","Cataloged from PDF version of thesis. \"August 2013.\"","Includes bibliographical references (pages 97-100)."]},{"key":"dc:description.abstract","label":"Abstract","values":["A stochastic optical reconstruction microscope was built and demonstrated for under $20,000, enabling hands-on learning of single-molecule localization concepts in teaching laboratories. This was accomplished by replacing the most expensive parts of $500,000 commercial instruments, namely the laser, camera, and objective, with lower cost alternatives. Since lower cost also comes with higher noise, we characterized the optical and noise characteristics of the microscope. A new sample protocol, consisting of microspheres labeled with streptavidin-Alexa 647 conjugates, was developed to test the system, compare the image quality of two reconstruction programs (QuickPALM and rapidSTORM), and evaluate trade-offs in camera selection. Finally, by imaging defined actin features in 3T3 cells, the instrument was estimated to have a sub-diffraction resolution between 70 -100 nm."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Ranbel F. Sun."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["100 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Low-cost educational stochastic optical reconstruction microscopy (eSTORM)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"41639513-371a-4556-8f53-d3e56f8f3dff\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Low-cost educational stochastic optical reconstruction microscopy (eSTORM)</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2013</PublicationDate> <Authors> <Author> <DisplayName>Sun, Ranbel F. (Ranbel Field)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>A stochastic optical reconstruction microscope was built and demonstrated for under $20,000, enabling hands-on learning of single-molecule localization concepts in teaching laboratories. This was accomplished by replacing the most expensive parts of $500,000 commercial instruments, namely the laser, camera, and objective, with lower cost alternatives. Since lower cost also comes with higher noise, we characterized the optical and noise characteristics of the microscope. A new sample protocol, consisting of microspheres labeled with streptavidin-Alexa 647 conjugates, was developed to test the system, compare the image quality of two reconstruction programs (QuickPALM and rapidSTORM), and evaluate trade-offs in camera selection. Finally, by imaging defined actin features in 3T3 cells, the instrument was estimated to have a sub-diffraction resolution between 70 -100 nm.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Edward S. Boyden."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Sun, Ranbel F. (Ranbel Field)"],"dc:date.accessioned":["2014-03-06T15:47:04Z"],"dc:date.available":["2014-03-06T15:47:04Z"],"dc:date.issued":["2013"],"dc:description":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, September 2013.","Cataloged from PDF version of thesis. \"August 2013.\"","Includes bibliographical references (pages 97-100)."],"dc:description.abstract":["A stochastic optical reconstruction microscope was built and demonstrated for under $20,000, enabling hands-on learning of single-molecule localization concepts in teaching laboratories. This was accomplished by replacing the most expensive parts of $500,000 commercial instruments, namely the laser, camera, and objective, with lower cost alternatives. Since lower cost also comes with higher noise, we characterized the optical and noise characteristics of the microscope. A new sample protocol, consisting of microspheres labeled with streptavidin-Alexa 647 conjugates, was developed to test the system, compare the image quality of two reconstruction programs (QuickPALM and rapidSTORM), and evaluate trade-offs in camera selection. Finally, by imaging defined actin features in 3T3 cells, the instrument was estimated to have a sub-diffraction resolution between 70 -100 nm."],"dc:description.degree":["M.Eng."],"dc:description.statementofresponsibility":["by Ranbel F. Sun."],"dc:format.extent":["100 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["871004481"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/85508"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Low-cost educational stochastic optical reconstruction microscopy (eSTORM)"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T07:24:40Z"}