{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/91864"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/91864","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Design of an improved electronics platform for the EyeRing wearable device","abstract":"This thesis presents a new prototype for EyeRing, a finger-worn device equipped with a camera and other peripherals. EyeRing is used in assistive technology applications, helping visually impaired people interact with uninstrumented environments. Applications for sighted people are also available to aid in learning, navigation, and other tasks. EyeRing is a wearable electronics device with an emphasis on natural gestural input and minimal interference. Previous prototypes used assemblies of commercial-off-the-shelf (COTS) control and sensing solutions. A more custom platform, consisting of two printed circuit boards (PCBs), peripherals, and firmware, was designed to make the device more usable and functional. Firmware was developed to ameliorate the communication capabilities, microcontroller functionality, and system power use. Improved features allow the pursual of previously unreachable application spaces. In addition, the smaller form factor increases usability and device acceptance. The new prototype improves power consumption by X, volume by Y, and throughput by Z. Video input is now available, etc.","abstract_html":"This thesis presents a new prototype for EyeRing, a finger-worn device equipped with a camera and other peripherals. EyeRing is used in assistive technology applications, helping visually impaired people interact with uninstrumented environments. Applications for sighted people are also available to aid in learning, navigation, and other tasks. EyeRing is a wearable electronics device with an emphasis on natural gestural input and minimal interference. Previous prototypes used assemblies of commercial-off-the-shelf (COTS) control and sensing solutions. A more custom platform, consisting of two printed circuit boards (PCBs), peripherals, and firmware, was designed to make the device more usable and functional. Firmware was developed to ameliorate the communication capabilities, microcontroller functionality, and system power use. Improved features allow the pursual of previously unreachable application spaces. In addition, the smaller form factor increases usability and device acceptance. The new prototype improves power consumption by X, volume by Y, and throughput by Z. Video input is now available, etc.","abstract_has_math":false,"creators":["Ran, Kelly (Kelly A.)"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Pattie Maes."],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014","date_published":"2014","updated_at":"2026-11-27T06:23:20Z","subjects":["Electrical Engineering and Computer Science."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["894354172"],"render_values":[{"text":"894354172","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/91864","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/91864","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F91864","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F91864","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Pattie Maes."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."]},{"key":"dc:creator","label":"Author","values":["Ran, Kelly (Kelly A.)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-11-24T18:40:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-11-24T18:40:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2014"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrical Engineering and Computer Science."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["894354172"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/91864"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"38c14ef6-5ef2-48b1-817a-712b2c3dbe07\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design of an improved electronics platform for the EyeRing wearable device</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014</PublicationDate> <Authors> <Author> <DisplayName>Ran, Kelly (Kelly A.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>This thesis presents a new prototype for EyeRing, a finger-worn device equipped with a camera and other peripherals. EyeRing is used in assistive technology applications, helping visually impaired people interact with uninstrumented environments. Applications for sighted people are also available to aid in learning, navigation, and other tasks. EyeRing is a wearable electronics device with an emphasis on natural gestural input and minimal interference. Previous prototypes used assemblies of commercial-off-the-shelf (COTS) control and sensing solutions. A more custom platform, consisting of two printed circuit boards (PCBs), peripherals, and firmware, was designed to make the device more usable and functional. Firmware was developed to ameliorate the communication capabilities, microcontroller functionality, and system power use. Improved features allow the pursual of previously unreachable application spaces. In addition, the smaller form factor increases usability and device acceptance. The new prototype improves power consumption by X, volume by Y, and throughput by Z. Video input is now available, etc.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, February 2014.","Cataloged from PDF version of thesis. \"September 2013.\"","Includes bibliographical references (pages 65-67)."]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents a new prototype for EyeRing, a finger-worn device equipped with a camera and other peripherals. EyeRing is used in assistive technology applications, helping visually impaired people interact with uninstrumented environments. Applications for sighted people are also available to aid in learning, navigation, and other tasks. EyeRing is a wearable electronics device with an emphasis on natural gestural input and minimal interference. Previous prototypes used assemblies of commercial-off-the-shelf (COTS) control and sensing solutions. A more custom platform, consisting of two printed circuit boards (PCBs), peripherals, and firmware, was designed to make the device more usable and functional. Firmware was developed to ameliorate the communication capabilities, microcontroller functionality, and system power use. Improved features allow the pursual of previously unreachable application spaces. In addition, the smaller form factor increases usability and device acceptance. The new prototype improves power consumption by X, volume by Y, and throughput by Z. Video input is now available, etc."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.Eng."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Kelly Ran."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["67 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design of an improved electronics platform for the EyeRing wearable device"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"38c14ef6-5ef2-48b1-817a-712b2c3dbe07\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Design of an improved electronics platform for the EyeRing wearable device</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2014</PublicationDate> <Authors> <Author> <DisplayName>Ran, Kelly (Kelly A.)</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Electrical Engineering and Computer Science.</Keyword> <Abstract>This thesis presents a new prototype for EyeRing, a finger-worn device equipped with a camera and other peripherals. EyeRing is used in assistive technology applications, helping visually impaired people interact with uninstrumented environments. Applications for sighted people are also available to aid in learning, navigation, and other tasks. EyeRing is a wearable electronics device with an emphasis on natural gestural input and minimal interference. Previous prototypes used assemblies of commercial-off-the-shelf (COTS) control and sensing solutions. A more custom platform, consisting of two printed circuit boards (PCBs), peripherals, and firmware, was designed to make the device more usable and functional. Firmware was developed to ameliorate the communication capabilities, microcontroller functionality, and system power use. Improved features allow the pursual of previously unreachable application spaces. In addition, the smaller form factor increases usability and device acceptance. The new prototype improves power consumption by X, volume by Y, and throughput by Z. Video input is now available, etc.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Pattie Maes."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science."],"dc:creator":["Ran, Kelly (Kelly A.)"],"dc:date.accessioned":["2014-11-24T18:40:56Z"],"dc:date.available":["2014-11-24T18:40:56Z"],"dc:date.issued":["2014"],"dc:description":["Thesis: M. Eng., Massachusetts Institute of Technology, Department of Electrical Engineering and Computer Science, February 2014.","Cataloged from PDF version of thesis. \"September 2013.\"","Includes bibliographical references (pages 65-67)."],"dc:description.abstract":["This thesis presents a new prototype for EyeRing, a finger-worn device equipped with a camera and other peripherals. EyeRing is used in assistive technology applications, helping visually impaired people interact with uninstrumented environments. Applications for sighted people are also available to aid in learning, navigation, and other tasks. EyeRing is a wearable electronics device with an emphasis on natural gestural input and minimal interference. Previous prototypes used assemblies of commercial-off-the-shelf (COTS) control and sensing solutions. A more custom platform, consisting of two printed circuit boards (PCBs), peripherals, and firmware, was designed to make the device more usable and functional. Firmware was developed to ameliorate the communication capabilities, microcontroller functionality, and system power use. Improved features allow the pursual of previously unreachable application spaces. In addition, the smaller form factor increases usability and device acceptance. The new prototype improves power consumption by X, volume by Y, and throughput by Z. Video input is now available, etc."],"dc:description.degree":["M.Eng."],"dc:description.statementofresponsibility":["by Kelly Ran."],"dc:format.extent":["67 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["894354172"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/91864"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Electrical Engineering and Computer Science."],"dc:title":["Design of an improved electronics platform for the EyeRing wearable device"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T06:23:20Z"}