{"id":{"repo_id":"mit","oai_identifier":"oai:dspace.mit.edu:1721.1/98663"},"canonical_url":"https://search.ndltd.org/etd/mit/oai:dspace.mit.edu:1721.1/98663","repository":{"repo_id":"mit","name":"MIT","base_url":"https://dspace.mit.edu/oai/request"},"display":{"title":"Fabrication of tissue scaffolds using projection micro-stereolithography","abstract":"In vitro liver models are a critical tool in pharmaceutical research, yet standard hepatocyte cultures fail to capture the complexity of in vivo tissue behavior. One of the most critical features of the in vivo liver is the extensive microvasculature which allows for the delivery of nutrients and metabolites without exposing hepatocytes to de-differentiating fluidic shear stresses. A new liver tissue scaffold design able to capture this histological organization may therefore improve the functional longevity of seeded hepatocytes. The additive manufacturing technique of projection micro-stereolithography (PuSL) proved capable of building non-cytotoxic and highly complex 3D structures with microvasculature on the order of 20 um inner diameter. While extensive biological testing remains to be carried out, the built structures reveal much promise in PuSL as a method of tissue scaffold fabrication in terms of in vivo mimicking architecture.","abstract_html":"In vitro liver models are a critical tool in pharmaceutical research, yet standard hepatocyte cultures fail to capture the complexity of in vivo tissue behavior. One of the most critical features of the in vivo liver is the extensive microvasculature which allows for the delivery of nutrients and metabolites without exposing hepatocytes to de-differentiating fluidic shear stresses. A new liver tissue scaffold design able to capture this histological organization may therefore improve the functional longevity of seeded hepatocytes. The additive manufacturing technique of projection micro-stereolithography (PuSL) proved capable of building non-cytotoxic and highly complex 3D structures with microvasculature on the order of 20 um inner diameter. While extensive biological testing remains to be carried out, the built structures reveal much promise in PuSL as a method of tissue scaffold fabrication in terms of in vivo mimicking architecture.","abstract_has_math":false,"creators":["Matsushita, Albert Keisuke"],"institution":"Massachusetts Institute of Technology","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":["Niels Holten-Andersen."],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015","date_published":"2015","updated_at":"2026-11-27T06:23:30Z","subjects":["Materials Science and Engineering."],"languages":["en"],"rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"rights_urls":["http://dspace.mit.edu/handle/1721.1/7582"],"identifier_entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["920678565"],"render_values":[{"text":"920678565","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/1721.1/98663","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/1721.1/98663","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amit%3Aoai%3Adspace.mit.edu%3A1721.1%2F98663","prefix":"oai_dc"},"source_record":{"url":"https://dspace.mit.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Adspace.mit.edu%3A1721.1%2F98663","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Niels Holten-Andersen."]},{"key":"dc:contributor.other","label":"Dc Contributor Other","values":["Massachusetts Institute of Technology. Department of Materials Science and Engineering."]},{"key":"dc:creator","label":"Author","values":["Matsushita, Albert Keisuke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-09-17T19:03:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-09-17T19:03:08Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2015"]},{"key":"dc:date.issued","label":"Date","values":["2015"]},{"key":"dc:publisher","label":"Institution","values":["Massachusetts Institute of Technology"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Materials Science and Engineering."]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://dspace.mit.edu/handle/1721.1/7582"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.oclc","label":"OCLC","values":["920678565"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/1721.1/98663"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"cerif:openaire","label":"Cerif Openaire","values":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3ada21e7-4356-4590-b4c7-1fef4db9aac6\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Fabrication of tissue scaffolds using projection micro-stereolithography</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015</PublicationDate> <Authors> <Author> <DisplayName>Matsushita, Albert Keisuke</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Materials Science and Engineering.</Keyword> <Abstract>In vitro liver models are a critical tool in pharmaceutical research, yet standard hepatocyte cultures fail to capture the complexity of in vivo tissue behavior. One of the most critical features of the in vivo liver is the extensive microvasculature which allows for the delivery of nutrients and metabolites without exposing hepatocytes to de-differentiating fluidic shear stresses. A new liver tissue scaffold design able to capture this histological organization may therefore improve the functional longevity of seeded hepatocytes. The additive manufacturing technique of projection micro-stereolithography (PuSL) proved capable of building non-cytotoxic and highly complex 3D structures with microvasculature on the order of 20 um inner diameter. While extensive biological testing remains to be carried out, the built structures reveal much promise in PuSL as a method of tissue scaffold fabrication in terms of in vivo mimicking architecture.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"]},{"key":"dc:description","label":"Description","values":["Thesis: S.B., Massachusetts Institute of Technology, Department of Materials Science and Engineering, 2015.","Cataloged from PDF version of thesis.","Includes bibliographical references (page 33)."]},{"key":"dc:description.abstract","label":"Abstract","values":["In vitro liver models are a critical tool in pharmaceutical research, yet standard hepatocyte cultures fail to capture the complexity of in vivo tissue behavior. One of the most critical features of the in vivo liver is the extensive microvasculature which allows for the delivery of nutrients and metabolites without exposing hepatocytes to de-differentiating fluidic shear stresses. A new liver tissue scaffold design able to capture this histological organization may therefore improve the functional longevity of seeded hepatocytes. The additive manufacturing technique of projection micro-stereolithography (PuSL) proved capable of building non-cytotoxic and highly complex 3D structures with microvasculature on the order of 20 um inner diameter. While extensive biological testing remains to be carried out, the built structures reveal much promise in PuSL as a method of tissue scaffold fabrication in terms of in vivo mimicking architecture."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["S.B."]},{"key":"dc:description.statementofresponsibility","label":"Dc Description Statementofresponsibility","values":["by Albert Keisuke Matsushita."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["33 pages"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Fabrication of tissue scaffolds using projection micro-stereolithography"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"others:access_status","label":"Others Access Status","values":["unknown"]}]}],"canonical_facts":{"cerif:openaire":["<Publication xmlns=\"https://www.openaire.eu/cerif-profile/1.1/\" id=\"3ada21e7-4356-4590-b4c7-1fef4db9aac6\"> <Type xmlns=\"https://www.openaire.eu/cerif-profile/vocab/COAR_Publication_Types\">http://purl.org/coar/resource_type/c_1843</Type> <Language>en</Language> <Title>Fabrication of tissue scaffolds using projection micro-stereolithography</Title> <PublishedIn> <Publication> </Publication> </PublishedIn> <PublicationDate>2015</PublicationDate> <Authors> <Author> <DisplayName>Matsushita, Albert Keisuke</DisplayName> <Affiliation> <OrgUnit> </OrgUnit> </Affiliation> </Author> </Authors> <Editors> </Editors> <Publishers> <Publisher> <DisplayName>Massachusetts Institute of Technology</DisplayName> <OrgUnit /> </Publisher> </Publishers> <License>http://dspace.mit.edu/handle/1721.1/7582</License> <Keyword>Materials Science and Engineering.</Keyword> <Abstract>In vitro liver models are a critical tool in pharmaceutical research, yet standard hepatocyte cultures fail to capture the complexity of in vivo tissue behavior. One of the most critical features of the in vivo liver is the extensive microvasculature which allows for the delivery of nutrients and metabolites without exposing hepatocytes to de-differentiating fluidic shear stresses. A new liver tissue scaffold design able to capture this histological organization may therefore improve the functional longevity of seeded hepatocytes. The additive manufacturing technique of projection micro-stereolithography (PuSL) proved capable of building non-cytotoxic and highly complex 3D structures with microvasculature on the order of 20 um inner diameter. While extensive biological testing remains to be carried out, the built structures reveal much promise in PuSL as a method of tissue scaffold fabrication in terms of in vivo mimicking architecture.</Abstract> <Access xmlns=\"http://purl.org/coar/access_right\" > </Access> </Publication>"],"dc:contributor.advisor":["Niels Holten-Andersen."],"dc:contributor.other":["Massachusetts Institute of Technology. Department of Materials Science and Engineering."],"dc:creator":["Matsushita, Albert Keisuke"],"dc:date.accessioned":["2015-09-17T19:03:08Z"],"dc:date.available":["2015-09-17T19:03:08Z"],"dc:date.copyright":["2015"],"dc:date.issued":["2015"],"dc:description":["Thesis: S.B., Massachusetts Institute of Technology, Department of Materials Science and Engineering, 2015.","Cataloged from PDF version of thesis.","Includes bibliographical references (page 33)."],"dc:description.abstract":["In vitro liver models are a critical tool in pharmaceutical research, yet standard hepatocyte cultures fail to capture the complexity of in vivo tissue behavior. One of the most critical features of the in vivo liver is the extensive microvasculature which allows for the delivery of nutrients and metabolites without exposing hepatocytes to de-differentiating fluidic shear stresses. A new liver tissue scaffold design able to capture this histological organization may therefore improve the functional longevity of seeded hepatocytes. The additive manufacturing technique of projection micro-stereolithography (PuSL) proved capable of building non-cytotoxic and highly complex 3D structures with microvasculature on the order of 20 um inner diameter. While extensive biological testing remains to be carried out, the built structures reveal much promise in PuSL as a method of tissue scaffold fabrication in terms of in vivo mimicking architecture."],"dc:description.degree":["S.B."],"dc:description.statementofresponsibility":["by Albert Keisuke Matsushita."],"dc:format.extent":["33 pages"],"dc:format.mimetype":["application/pdf"],"dc:identifier.oclc":["920678565"],"dc:identifier.uri":["http://hdl.handle.net/1721.1/98663"],"dc:language.iso":["en"],"dc:publisher":["Massachusetts Institute of Technology"],"dc:rights":["M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission."],"dc:rights.uri":["http://dspace.mit.edu/handle/1721.1/7582"],"dc:subject":["Materials Science and Engineering."],"dc:title":["Fabrication of tissue scaffolds using projection micro-stereolithography"],"dc:type":["Thesis"],"dspace:entity.type":["Publication"],"others:access_status":["unknown"]},"updated_at":"2026-11-27T06:23:30Z"}