{"id":{"repo_id":"montana-tech","oai_identifier":"oai:scholarworks.umt.edu:etd-13129"},"canonical_url":"https://search.ndltd.org/etd/montana-tech/oai:scholarworks.umt.edu:etd-13129","repository":{"repo_id":"montana-tech","name":"Montana Technology","base_url":"https://scholarworks.umt.edu/do/oai/"},"display":{"title":"THE EFFECTS HUMIDITY & TEMPERATURE HAS ON DNA CONTAMINATION DURING STORAGE","abstract":"Studies have been conducted on DNA cross-contamination throughout the criminal investigation process in order to evaluation the possibility that DNA from one sample could potentially influence the outcome of another. However, no published studies have examined the potential for contamination during the storage of genetic evidence after samples have been taken from crime scenes or suspects. This study is a continuation of a preliminary project, which examined storage drying time in relation to cross-contamination. The current study tested temperature and humidity for the potential of cross-contamination during storage prior to extraction. Prior to storage, 50 μl of male saliva was aliquoted to buccal swabs and then dried for 20 minutes in a Dry-Fast swab dryer. Each variable tested consisted of five buccal swabs that were introduced to DNA and five swabs that remained unopened, in order to see if the male DNA could then be detected on the unopened swabs. Cross-contamination was not detected below 8 °C or 35% relative humidity. Any DNA that was detected was unable to produce a STR profile either as result of nonspecific amplification or extremely low levels of DNA, suggesting that if it did move, it was not enough DNA to alter results. However, further research is needed to determine if higher levels of humidity impact the movement of DNA.","abstract_html":"Studies have been conducted on DNA cross-contamination throughout the criminal investigation process in order to evaluation the possibility that DNA from one sample could potentially influence the outcome of another. However, no published studies have examined the potential for contamination during the storage of genetic evidence after samples have been taken from crime scenes or suspects. This study is a continuation of a preliminary project, which examined storage drying time in relation to cross-contamination. The current study tested temperature and humidity for the potential of cross-contamination during storage prior to extraction. Prior to storage, 50 μl of male saliva was aliquoted to buccal swabs and then dried for 20 minutes in a Dry-Fast swab dryer. Each variable tested consisted of five buccal swabs that were introduced to DNA and five swabs that remained unopened, in order to see if the male DNA could then be detected on the unopened swabs. Cross-contamination was not detected below 8 °C or 35% relative humidity. Any DNA that was detected was unable to produce a STR profile either as result of nonspecific amplification or extremely low levels of DNA, suggesting that if it did move, it was not enough DNA to alter results. However, further research is needed to determine if higher levels of humidity impact the movement of DNA.","abstract_has_math":false,"creators":["Ramey, Samantha Leigh Allison"],"institution":"University of Montana","degree_name":"Doctor of Philosophy (PhD)","degree_level":null,"degree_discipline":null,"degree_department":"Department of Anthropology","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T08:39:38Z","subjects":["Contamination","DNA","Storage"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarworks.umt.edu/etd/12017","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarworks.umt.edu/etd/12017","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Amontana-tech%3Aoai%3Ascholarworks.umt.edu%3Aetd-13129","prefix":"oai_dc"},"source_record":{"url":"https://scholarworks.umt.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarworks.umt.edu%3Aetd-13129","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.role","label":"Dc Contributor Role","values":["Meradeth Snow"]},{"key":"dc:creator","label":"Author","values":["Ramey, Samantha Leigh Allison"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2022-01-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Montana"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_department","label":"Department","values":["Department of Anthropology"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Contamination","DNA","Storage"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarworks.umt.edu/etd/12017"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Studies have been conducted on DNA cross-contamination throughout the criminal investigation process in order to evaluation the possibility that DNA from one sample could potentially influence the outcome of another. However, no published studies have examined the potential for contamination during the storage of genetic evidence after samples have been taken from crime scenes or suspects. This study is a continuation of a preliminary project, which examined storage drying time in relation to cross-contamination. The current study tested temperature and humidity for the potential of cross-contamination during storage prior to extraction. Prior to storage, 50 μl of male saliva was aliquoted to buccal swabs and then dried for 20 minutes in a Dry-Fast swab dryer. Each variable tested consisted of five buccal swabs that were introduced to DNA and five swabs that remained unopened, in order to see if the male DNA could then be detected on the unopened swabs. Cross-contamination was not detected below 8 °C or 35% relative humidity. Any DNA that was detected was unable to produce a STR profile either as result of nonspecific amplification or extremely low levels of DNA, suggesting that if it did move, it was not enough DNA to alter results. However, further research is needed to determine if higher levels of humidity impact the movement of DNA."]},{"key":"dc:title","label":"Title","values":["THE EFFECTS HUMIDITY & TEMPERATURE HAS ON DNA CONTAMINATION DURING STORAGE"]}]}],"canonical_facts":{"dc:contributor.role":["Meradeth Snow"],"dc:creator":["Ramey, Samantha Leigh Allison"],"dc:date.created":["2022-01-01T08:00:00Z"],"dc:description.abstract":["Studies have been conducted on DNA cross-contamination throughout the criminal investigation process in order to evaluation the possibility that DNA from one sample could potentially influence the outcome of another. However, no published studies have examined the potential for contamination during the storage of genetic evidence after samples have been taken from crime scenes or suspects. This study is a continuation of a preliminary project, which examined storage drying time in relation to cross-contamination. The current study tested temperature and humidity for the potential of cross-contamination during storage prior to extraction. Prior to storage, 50 μl of male saliva was aliquoted to buccal swabs and then dried for 20 minutes in a Dry-Fast swab dryer. Each variable tested consisted of five buccal swabs that were introduced to DNA and five swabs that remained unopened, in order to see if the male DNA could then be detected on the unopened swabs. Cross-contamination was not detected below 8 °C or 35% relative humidity. Any DNA that was detected was unable to produce a STR profile either as result of nonspecific amplification or extremely low levels of DNA, suggesting that if it did move, it was not enough DNA to alter results. However, further research is needed to determine if higher levels of humidity impact the movement of DNA."],"dc:identifier":["https://scholarworks.umt.edu/etd/12017"],"dc:publisher":["University of Montana"],"dc:subject":["Contamination","DNA","Storage"],"dc:title":["THE EFFECTS HUMIDITY & TEMPERATURE HAS ON DNA CONTAMINATION DURING STORAGE"],"dc:type":["Dissertation"],"thesis:degree_department":["Department of Anthropology"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-19T08:39:38Z"}