{"id":{"repo_id":"msu","oai_identifier":"oai:d.lib.msu.edu:etd_19660"},"canonical_url":"https://search.ndltd.org/etd/msu/oai:d.lib.msu.edu:etd_19660","repository":{"repo_id":"msu","name":"Michigan State University","base_url":"https://d.lib.msu.edu/oai"},"display":{"title":"Nonuniform flow over a thermal transient anemometer","abstract":"An experiment and a simulation have been created to determine if a Thermal Transient Anemometer (TTA) has the capability to measure a nonuniform fluid flow and to output an appropriate average uniform flow. A frame was created with 23 cells that holds a tungsten sensing wire that was heated with an electrical current and cooled with a passing flow. The TTA was then simulated, using an energy balance equation as a basis, to test with more nonuniform flows. The source of axial heat transfer caused the TTA to cool slower with a nonuniform flow than an equivalent uniform flow at an averaged flow speed. The percent the nonuniform flow differed from this equivalent averaged flow changed based was on two main factors of the flow; if any region of the flow existed at low speeds and if the flow has large gradients. With this in mind the TTA will still have a usable operational condition. Namely, if the flow is not at a low speed and if it has a modest gradient.","abstract_html":"An experiment and a simulation have been created to determine if a Thermal Transient Anemometer (TTA) has the capability to measure a nonuniform fluid flow and to output an appropriate average uniform flow. A frame was created with 23 cells that holds a tungsten sensing wire that was heated with an electrical current and cooled with a passing flow. The TTA was then simulated, using an energy balance equation as a basis, to test with more nonuniform flows. The source of axial heat transfer caused the TTA to cool slower with a nonuniform flow than an equivalent uniform flow at an averaged flow speed. The percent the nonuniform flow differed from this equivalent averaged flow changed based was on two main factors of the flow; if any region of the flow existed at low speeds and if the flow has large gradients. With this in mind the TTA will still have a usable operational condition. Namely, if the flow is not at a low speed and if it has a modest gradient.","abstract_has_math":false,"creators":["Leung, James"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Klausner, James F.","Foss, John","Benard, Andre","Michigan State University"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2018,"date_issued":"2018","date_published":"2018","updated_at":"2026-11-18T17:43:22Z","subjects":["Unsteady flow (Fluid dynamics)","Unsteady flow (Aerodynamics)","Heat--Transmission--Measurement","Fluid dynamic measurements","Anemometer"],"languages":["English"],"rights":["In Copyright"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:19660","isbn:9780438757356","isbn:0438757351","oclc:1117774589","umi:13424396","local:Leung_grad.msu_0128N_16573"],"render_values":[{"text":"etd:19660","href":null,"code":true},{"text":"isbn:9780438757356","href":null,"code":true},{"text":"isbn:0438757351","href":null,"code":true},{"text":"oclc:1117774589","href":null,"code":true},{"text":"umi:13424396","href":null,"code":true},{"text":"local:Leung_grad.msu_0128N_16573","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/doi:10.25335/6wy4-je93","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/doi:10.25335/6wy4-je93","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://d.lib.msu.edu/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Ad.lib.msu.edu%3Aetd_19660","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Klausner, James F.","Foss, John","Benard, Andre","Michigan State University"]},{"key":"dc:creator","label":"Author","values":["Leung, James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2018"]},{"key":"dc:relation","label":"Dc Relation","values":["Electronic Theses & Dissertations"]},{"key":"dc:type","label":"Dc Type","values":["Text","Theses"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Unsteady flow (Fluid dynamics)","Unsteady flow (Aerodynamics)","Heat--Transmission--Measurement","Fluid dynamic measurements","Anemometer"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["etd:19660","isbn:9780438757356","isbn:0438757351","oclc:1117774589","umi:13424396","local:Leung_grad.msu_0128N_16573","https://doi.org/doi:10.25335/6wy4-je93"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["An experiment and a simulation have been created to determine if a Thermal Transient Anemometer (TTA) has the capability to measure a nonuniform fluid flow and to output an appropriate average uniform flow. A frame was created with 23 cells that holds a tungsten sensing wire that was heated with an electrical current and cooled with a passing flow. The TTA was then simulated, using an energy balance equation as a basis, to test with more nonuniform flows. The source of axial heat transfer caused the TTA to cool slower with a nonuniform flow than an equivalent uniform flow at an averaged flow speed. The percent the nonuniform flow differed from this equivalent averaged flow changed based was on two main factors of the flow; if any region of the flow existed at low speeds and if the flow has large gradients. With this in mind the TTA will still have a usable operational condition. Namely, if the flow is not at a low speed and if it has a modest gradient.","Thesis (M.S.)--Michigan State University. Mechanical Engineering, 2018","Includes bibliographical references (page 65)"]},{"key":"dc:format","label":"Dc Format","values":["xi, 66 pages","application/pdf"]},{"key":"dc:title","label":"Title","values":["Nonuniform flow over a thermal transient anemometer"]}]}],"canonical_facts":{"dc:contributor":["Klausner, James F.","Foss, John","Benard, Andre","Michigan State University"],"dc:creator":["Leung, James"],"dc:date":["2018"],"dc:description":["An experiment and a simulation have been created to determine if a Thermal Transient Anemometer (TTA) has the capability to measure a nonuniform fluid flow and to output an appropriate average uniform flow. A frame was created with 23 cells that holds a tungsten sensing wire that was heated with an electrical current and cooled with a passing flow. The TTA was then simulated, using an energy balance equation as a basis, to test with more nonuniform flows. The source of axial heat transfer caused the TTA to cool slower with a nonuniform flow than an equivalent uniform flow at an averaged flow speed. The percent the nonuniform flow differed from this equivalent averaged flow changed based was on two main factors of the flow; if any region of the flow existed at low speeds and if the flow has large gradients. With this in mind the TTA will still have a usable operational condition. Namely, if the flow is not at a low speed and if it has a modest gradient.","Thesis (M.S.)--Michigan State University. Mechanical Engineering, 2018","Includes bibliographical references (page 65)"],"dc:format":["xi, 66 pages","application/pdf"],"dc:identifier":["etd:19660","isbn:9780438757356","isbn:0438757351","oclc:1117774589","umi:13424396","local:Leung_grad.msu_0128N_16573","https://doi.org/doi:10.25335/6wy4-je93"],"dc:language":["English"],"dc:relation":["Electronic Theses & Dissertations"],"dc:rights":["In Copyright"],"dc:subject":["Unsteady flow (Fluid dynamics)","Unsteady flow (Aerodynamics)","Heat--Transmission--Measurement","Fluid dynamic measurements","Anemometer"],"dc:title":["Nonuniform flow over a thermal transient anemometer"],"dc:type":["Text","Theses"]},"updated_at":"2026-11-18T17:43:22Z"}